| Literature DB >> 33590715 |
Pieter F van der Meer1,2,3, Sanne K Verbakel4, Áine Honohan2,5, Jos Lorinser1, Rogier M Thurlings6, Joannes F M Jacobs7, Dirk de Korte1,8, Catharina A Eggink4.
Abstract
PURPOSE: Serum eye drops (SEDs) are used to treat a variety of ocular surface defects. Serum eye drops (SEDs) are normally produced from the patient's blood. However, not all patients can donate sufficient or suitable blood, and logistics can be challenging. Allogeneic blood from voluntary blood donors does not have these disadvantages. Our aim was to evaluate whether autologous and allogeneic SEDs have comparable efficacy and tolerability.Entities:
Keywords: Sjögren disease; allogeneic; autologous; serum eye drops; severe dry eye syndrome
Mesh:
Substances:
Year: 2021 PMID: 33590715 PMCID: PMC9544559 DOI: 10.1111/aos.14788
Source DB: PubMed Journal: Acta Ophthalmol ISSN: 1755-375X Impact factor: 3.988
Baseline patient characteristics of included patients.
| Patients ( | |
|---|---|
| Sex, | |
| Female | 14 (93) |
| Male | 1 (7) |
| Age, mean (SD) | 73 (9) |
| Underlying eye disease, | |
| Extreme dry eye disease | 9 (60) |
| Sjögren’s syndrome | 3 (20) |
| Other | 3 (20) |
| Standard Ocular Surface Medication/Therapy, | |
| Artificial tear product | 13 (87) |
| Gel for dry eyes | 6 (40) |
| Ointment | 1 (7) |
| OSDI, mean (SD) | 60 (19) |
IQR = interquartile range, SD = standard deviation.
Ocular Surface Disease Index before and after treatment with autologous and allogeneic SEDs and pre‐ and post‐treatment differences
| Autologous SEDs | Allogeneic SEDs | |
|---|---|---|
|
| 15 | 15 |
| OSDI pre, mean (SD) | 62 (19) | 59 (20) |
| OSDI post, mean (SD) | 57 (18) | 56 (23) |
| Estimated mean difference (95% CI) | −4.2 (−9.5 to 1.2) | −4.5 (−9.8 to 0.9) |
CI = confidence interval, SD = standard deviation.
not significant, p > 0.05.
Estimated secondary outcome measures before and after treatment with autologous and allogeneic SEDs.
| Autologous SEDs | Allogeneic SEDs | |
|---|---|---|
|
| 15/29 | 15/29 |
| Tear break up time, s | ||
| Pre, estimated mean (SE) | 8.5 (0.6) | 7.2 (0.5) |
| Post, estimated mean (SE) | 8.4 (0.7) | 7.5 (0.6) |
| Estimated mean difference (95% CI) | −0.11 (−1.4 to 1.2) | 0.21 (−0.9 to 1.3) |
| Tear production time, mm/5min | ||
| Pre, estimated mean (SE) | 5.9 (0.8) | 9.7 (1.5) |
| Post, estimated mean (SE) | 7.5 (0.8) | 8.2 (1.2) |
| Estimated mean difference (95% CI) | 1.55 (0.32 to 2.8) | −1.6 (−3.6 to 0.49) |
| Corneal punctate lesions, % | ||
| Pre, estimated mean (SE) | 19 (3) | 26 (5) |
| Post, estimated mean (SE) | 21 (5) | 22 (5) |
| Estimated mean difference (95% CI) | 2 (−5 to 9) | −3 (−12 to 5) |
| LogMAR | ||
| Pre, estimated mean (SE) | 0.009 (0.280) | 0.090 (0.040) |
| Post, estimated mean (SE) | −0.035 (0.230) | 0.017 (0.031) |
| Estimated mean difference (95% CI) | −0.044 (−0.90 to 0.001) | −0.073 (−0.110 to 0.036) |
CI = confidence interval, SE = standard error.