Literature DB >> 33590323

Novel Minimal Radiation Approach for Percutaneous Pulmonary Valve Implantation.

Jenny E Zablah1,2, Salvador A Rodriguez3,4, Ryan Leahy3,4, Gareth J Morgan3,4,5.   

Abstract

The aim of the study is to evaluate the impact of multimodality imaging technology during percutaneous pulmonary valve implantation (PPVI). Among percutaneous procedures, PPVI traditionally has one of the highest patient radiation exposures. Different protocol modifications have been implemented to address this problem (i.e., improvements in guidance systems, delivery systems, valve design, post-implantation evaluation). Although the effectiveness of individual modifications has been proven, the effect of an approach which combines these changes has not been reported. We performed a retrospective chart review of 76 patients who underwent PPVI between January 2018 and December 2019. Patients were classified in "Traditional protocol," using routine biplane angiography and/or 3D rotational angiography (3DRA); and "Multimodality protocol" that included the use of VesselNavigator for guidance, selective 3DRA for coronary evaluation, Long DrySeal Sheath for valve delivery, and Intracardiac Echocardiography for valve evaluation after implantation. Radiation metrics, procedural time, and clinical outcomes were compared between groups. When the traditional protocol group was compared with the multimodality protocol group, a significant reduction was described for total fluoroscopy time (31.6 min vs. 26.2 min), dose of contrast per kilogram (1.8 mL/Kg vs. 0.9 mL/Kg), DAP/kg (26.6 µGy·m2/kg vs. 19.9 µGy·m2/kg), and Air Kerma (194 mGy vs. 99.9 mGy). A reduction for procedure time was noted (140 min vs. 116.5 min), but this was not statistically significant. There was no difference in clinical outcomes or the presence of complications between groups. The combination of novel technology in PPVI caused a significant reduction in radiation metrics without increasing the complication rate in our population.

Entities:  

Keywords:  Congenital heart disease; Pediatric intervention; Percutaneous pulmonary valve replacement; Radiation reduction

Year:  2021        PMID: 33590323     DOI: 10.1007/s00246-021-02564-7

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  13 in total

Review 1.  Birth prevalence of congenital heart disease worldwide: a systematic review and meta-analysis.

Authors:  Denise van der Linde; Elisabeth E M Konings; Maarten A Slager; Maarten Witsenburg; Willem A Helbing; Johanna J M Takkenberg; Jolien W Roos-Hesselink
Journal:  J Am Coll Cardiol       Date:  2011-11-15       Impact factor: 24.094

2.  Safety and Feasibility of Melody Transcatheter Pulmonary Valve Replacement in the Native Right Ventricular Outflow Tract: A Multicenter Pediatric Heart Network Scholar Study.

Authors:  Mary Hunt Martin; Jeffery Meadows; Doff B McElhinney; Bryan H Goldstein; Lisa Bergersen; Athar M Qureshi; Shabana Shahanavaz; Jamil Aboulhosn; Darren Berman; Lynn Peng; Matthew Gillespie; Aimee Armstrong; Cindy Weng; L LuAnn Minich; Robert G Gray
Journal:  JACC Cardiovasc Interv       Date:  2018-08-01       Impact factor: 11.195

3.  Adverse Events, Radiation Exposure, and Reinterventions Following Transcatheter Pulmonary Valve Replacement.

Authors:  Bryan H Goldstein; Lisa Bergersen; Aimee K Armstrong; Brian A Boe; Howaida El-Said; Diego Porras; Shabana Shahanavaz; Ryan A Leahy; Jacqueline Kreutzer; Jeffrey D Zampi; Michael R Hainstock; Todd M Gudausky; George T Nicholson; Kimberlee Gauvreau; Andrea Goodman; Christopher J Petit
Journal:  J Am Coll Cardiol       Date:  2020-02-04       Impact factor: 24.094

4.  Use and performance of the Melody Transcatheter Pulmonary Valve in native and postsurgical, nonconduit right ventricular outflow tracts.

Authors:  Jeffery J Meadows; Phillip M Moore; Darren P Berman; John P Cheatham; Sharon L Cheatham; Diego Porras; Matthew J Gillespie; Jonathan J Rome; Evan M Zahn; Doff B McElhinney
Journal:  Circ Cardiovasc Interv       Date:  2014-05-27       Impact factor: 6.546

5.  Trends in pulmonary valve replacement in children and adults with tetralogy of fallot.

Authors:  Michael L O'Byrne; Andrew C Glatz; Laura Mercer-Rosa; Matthew J Gillespie; Yoav Dori; Elizabeth Goldmuntz; Steven Kawut; Jonathan J Rome
Journal:  Am J Cardiol       Date:  2014-10-16       Impact factor: 2.778

6.  Reducing Radiation Exposure in Cardiac Catheterizations for Congenital Heart Disease.

Authors:  Chandni Patel; Matthew Grossman; Veronika Shabanova; Jeremy Asnes
Journal:  Pediatr Cardiol       Date:  2018-12-12       Impact factor: 1.655

7.  Radiation Exposure by Three-Dimensional Rotational Angiography (3DRA) During Trans-catheter Melody Pulmonary Valve Procedures (TMPV) in a Pediatric Cardiac Catheterization Laboratory.

Authors:  Hoang H Nguyen; David T Balzer; Joshua J Murphy; Ramzi Nicolas; Shabana Shahanavaz
Journal:  Pediatr Cardiol       Date:  2016-07-25       Impact factor: 1.655

8.  Congenital heart disease in a cohort of 19,502 births with long-term follow-up.

Authors:  J I Hoffman; R Christianson
Journal:  Am J Cardiol       Date:  1978-10       Impact factor: 2.778

9.  Cumulative radiation exposure and cancer risk estimation in children with heart disease.

Authors:  Jason N Johnson; Christoph P Hornik; Jennifer S Li; Daniel K Benjamin; Terry T Yoshizumi; Robert E Reiman; Donald P Frush; Kevin D Hill
Journal:  Circulation       Date:  2014-06-09       Impact factor: 29.690

10.  Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance.

Authors:  S Goreczny; T Moszura; P Dryzek; M Lukaszewski; A Krawczuk; J Moll; G J Morgan
Journal:  Neth Heart J       Date:  2017-02       Impact factor: 2.380

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.