Literature DB >> 33588475

[Validation of a cow-side blood test for beta-hydroxybutyrate concentration in dairy cows].

Teja Snedec1, Kirsten Theinert1, Fabian Pietsch1, Anne-Sophie Leonhardt1, Marián Kadáši2, Robert Klein2, Joachim Spilke3, Erik Bannert1, Melanie Schären1, Gabor Köller1, Walter Baumgartner4, Sabrina Theile5, Anne Kaiser1, Fanny Rachidi1, Alexander Starke1.   

Abstract

OBJECTIVE: Clinical ketosis is common during the dairy cows' transition period and is responsible for considerable economic loss. Early identification of cows with subclinical ketosis is the first step for maintaining the health and productivity of dairy cows. The goals of the study were two-fold: The first was to examine the usefulness of a mobile test device as a cow-side test; and the second was to compare BHB concentrations measured by the ketometer using capillary blood and blood collected from the coccygeal vessels with values determined by a reference method in the laboratory using jugular blood.
MATERIAL AND METHODS: Blood samples were collected from a jugular vein or the coccygeal vessels in 81 dairy cows at 7 time points (14 and 7 days pre-partum and 7, 14, 21, 28, and 42 days post-partum) for kinetic enzymatic measurement of BHB concentration in the laboratory. Blood samples were concurrently collected from the coccygeal vessels or by pricking the vulvar lip at the transition of the skin to the mucosa (capillary blood) to determine BHB concentration using the WellionVet BELUA ketometer (MED TRUST GmbH, Marz, Austria).
RESULTS: Initial errors in operating the ketometer were quickly eliminated with experience. BHB concentrations of jugular blood measured in the laboratory were 0.07 mmol/l lower than those measured in coccygeal blood. The mean BHB concentration measured in coccygeal and capillary blood using the WellionVet BELUA ketometer did not significantly differ but were 0.13 and 0.12 mmol/l respectively, lower than the mean jugular vein concentrations measured in the laboratory.
CONCLUSION: The WellionVet BELUA ketometer is useful for determination of BHB concentration in cows provided that the manufacturer's specifications are followed. Capillary blood is best collected at the transition from the vulvar skin to its mucosa. The device generates rapid results that correlate well with BHB concentrations determined in the laboratory and with the results obtained from different blood collection sites. It is ideally suited for monitoring dairy cows for subclinical ketosis using capillary or coccygeal blood. Thieme. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33588475     DOI: 10.1055/a-1320-4203

Source DB:  PubMed          Journal:  Tierarztl Prax Ausg G Grosstiere Nutztiere        ISSN: 1434-1220            Impact factor:   0.488


  1 in total

1.  Qualitative and Quantitative Changes in Total Lipid Concentration and Lipid Fractions in Liver Tissue of Periparturient German Holstein Dairy Cows of Two Age Groups.

Authors:  Kirsten B Theinert; Teja Snedec; Fabian Pietsch; Sabrina Theile; Anne-Sophie Leonhardt; Joachim Spilke; Stefan Pichelmann; Erik Bannert; Kristin Reichelt; Gabriele Dobeleit; Herbert Fuhrmann; Walter Baumgartner; Melanie Schären-Bannert; Alexander Starke
Journal:  Front Vet Sci       Date:  2022-03-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.