| Literature DB >> 33587982 |
Abhijoy Chakladar1, Claire G Jones2, Jimmy Siu2, Mohammed Osman Hassan-Ibrahim3, Mansoor Khan4.
Abstract
BACKGROUND: Powered air purifying respirators (PAPR) are an option for healthcare workers requiring respiratory protection during the current COVID-19 pandemic; they are shared between multiple people. PAPR hoods are intended for multiple uses by a single user and may pose an infection risk between wearers.Entities:
Keywords: Disinfection; Infection prevention and control; Personal protective equipment (PPE); Respirators
Mesh:
Year: 2021 PMID: 33587982 PMCID: PMC7880844 DOI: 10.1016/j.ajic.2021.02.006
Source DB: PubMed Journal: Am J Infect Control ISSN: 0196-6553 Impact factor: 2.918
Fig. 13M Scott FH1 and FH2 Headtops and PAPR arrangement.
Fig. 2Swabbing PAPR hoods and fan tubing.
Positive swab results
| Hood | Model | Part | Bacteria | Viral panel | SARS-CoV-2 | Fungal | Storage |
|---|---|---|---|---|---|---|---|
| 4 | FH1 | Visor | Bacillus simplex | x | x | x | Open ward |
| 12 | FH1 | Visor | x | x | x | NSEM | Drying hook |
| 13 | FH1 | Visor | x | x | x | NSEM | Open box |
| 15 | FH1 | Visor | x | x | x | NSEM | Open box |
| 16 | FH1 | Hose | Kocuria rhizophilia | x | x | x | Sealed box |
| 19 | FH1 | Visor | x | x | x | NSEM | Sealed box |
| 20 | FH1 | Visor | Bacillus weihenstephensis | x | x | x | Open box |
| 21 | FH2 | Hose | Microcccus luteus | x | x | x | Open box |
| 23 | FH1 | Visor | Staphylococcus epidermidis | x | x | NSEM | Open box |
| 25 | FH2 | Visor | Microcccus luteus | x | x | x | Open box |
| 25 | FH2 | Hose | Microcccus luteus | x | x | x | Open box |
FH1/FH2, model of 3M Scott PAPR Headtop; NSEM, nonsporulating environmental mould; x, negative swab.