Literature DB >> 33583946

The Ring-Pull Assay for Mechanical Properties of Fibrous Soft Tissues - An Analysis of the Uniaxial Approximation and a Correction for Nonlinear Thick-Walled Tissues.

R R Mahutga1, C T Schoephoerster1, V H Barocas1.   

Abstract

BACKGROUND: The ring-pull test, where a ring of tissue is hooked via two pins and stretched, is a popular biomechanical test, especially for small arteries. Although convenient and reliable, the ring test produces inhomogeneous strain, making determination of material parameters non-trivial.
OBJECTIVE: To determine correction factors between ring-pull-estimated and true tissue properties.
METHODS: A finite-element model of ring pulling was constructed for a sample with nonlinear, anisotropic mechanical behavior typical of arteries. The pin force and sample cross-section were used to compute an apparent modulus at small and large strain, which were compared to the specified properties. The resulting corrections were validated with experiments on porcine and ovine arteries. The correction was further applied to experiments on mouse aortic rings to determine material and failure properties.
RESULTS: Calculating strain based on centerline stretch rather than inner-wall or outer-wall stretch afforded better estimation of tissue properties. Additional correction factors were developed based on ring wall thickness H, centerline ring radius R c , and pin radius a. The corrected estimates for tissue properties were in good agreement with uniaxial stretch experiments.
CONCLUSIONS: The computed corrections improved estimation of tissue material properties for both the small-strain (toe) modulus and the large-strain (lockout) modulus. When measuring tensile strength, one should minimize H/a to ensure that peak stress occurs at the sample midplane rather than near the pin. In this scenario, tensile strength can be estimated accurately by using inner-wall stretch at the midplane and the corrected properties.

Entities:  

Keywords:  anisotropic; arterial biomechanics; cardiovascular biomechanics; computational biomechanics; large strain; nonlinear; soft biological tissue; uniaxial ring-pull

Year:  2020        PMID: 33583946      PMCID: PMC7880234          DOI: 10.1007/s11340-020-00623-3

Source DB:  PubMed          Journal:  Exp Mech        ISSN: 0014-4851            Impact factor:   2.808


  14 in total

1.  Mechanical characterization of the bovine iris.

Authors:  J Heys; V H Barocas
Journal:  J Biomech       Date:  1999-09       Impact factor: 2.712

2.  FEBio: finite elements for biomechanics.

Authors:  Steve A Maas; Benjamin J Ellis; Gerard A Ateshian; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2012-01       Impact factor: 2.097

3.  Mechanical contribution of lamellar and interlamellar elastin along the mouse aorta.

Authors:  T E Clark; M A Lillie; A W Vogl; J M Gosline; R E Shadwick
Journal:  J Biomech       Date:  2015-08-10       Impact factor: 2.712

4.  Neonatal murine heart slices. A robust model to study ventricular isometric contractions.

Authors:  Frank Pillekamp; Marcel Halbach; Michael Reppel; Olga Rubenchyk; Kurt Pfannkuche; Jiao-Ya Xi; Wilhelm Bloch; Narayanswami Sreeram; Konrad Brockmeier; Juergen Hescheler
Journal:  Cell Physiol Biochem       Date:  2007

5.  Passive mechanical properties and structure of the aorta: segmental analysis.

Authors:  D P Sokolis
Journal:  Acta Physiol (Oxf)       Date:  2007-08       Impact factor: 6.311

6.  Isotropic Failure Criteria Are Not Appropriate for Anisotropic Fibrous Biological Tissues.

Authors:  Christopher E Korenczuk; Lauren E Votava; Rohit Y Dhume; Shannen B Kizilski; George E Brown; Rahul Narain; Victor H Barocas
Journal:  J Biomech Eng       Date:  2017-07-01       Impact factor: 2.097

7.  Mechanical properties of the colon: comparison of the features of the African and European colon in vitro.

Authors:  D A Watters; A N Smith; M A Eastwood; K C Anderson; R A Elton; J W Mugerwa
Journal:  Gut       Date:  1985-04       Impact factor: 23.059

8.  Material properties of mouse cervical tissue in normal gestation.

Authors:  Kyoko Yoshida; Mala Mahendroo; Joy Vink; Ronald Wapner; Kristin Myers
Journal:  Acta Biomater       Date:  2016-03-04       Impact factor: 8.947

9.  Mechanisms of stiffening and strengthening in media-equivalents fabricated using glycation.

Authors:  T S Girton; T R Oegema; E D Grassl; B C Isenberg; R T Tranquillo
Journal:  J Biomech Eng       Date:  2000-06       Impact factor: 2.097

10.  The role of type I collagen in aortic wall strength with a homotrimeric.

Authors:  A G Vouyouka; B J Pfeiffer; T K Liem; T A Taylor; J Mudaliar; C L Phillips
Journal:  J Vasc Surg       Date:  2001-06       Impact factor: 4.268

View more
  1 in total

1.  Through-thickness regional variation in the mechanical characteristics of the lumbar facet capsular ligament.

Authors:  Elizabeth Gacek; Emily A Bermel; Arin M Ellingson; Victor H Barocas
Journal:  Biomech Model Mechanobiol       Date:  2021-03-31
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.