Literature DB >> 33580348

Novel deep learning-based noise reduction technique for prostate magnetic resonance imaging.

Xinzeng Wang1,2, Jingfei Ma2, Priya Bhosale3, Juan J Ibarra Rovira3, Aliya Qayyum3, Jia Sun4, Ersin Bayram1,2, Janio Szklaruk5.   

Abstract

INTRODUCTION: Magnetic resonance imaging (MRI) has played an increasingly major role in the evaluation of patients with prostate cancer, although prostate MRI presents several technical challenges. Newer techniques, such as deep learning (DL), have been applied to medical imaging, leading to improvements in image quality. Our goal is to evaluate the performance of a new deep learning-based reconstruction method, "DLR" in improving image quality and mitigating artifacts, which is now commercially available as AIRTM Recon DL (GE Healthcare, Waukesha, WI). We hypothesize that applying DLR to the T2WI images of the prostate provides improved image quality and reduced artifacts.
METHODS: This study included 31 patients with a history of prostate cancer that had a multiparametric MRI of the prostate with an endorectal coil (ERC) at 1.5 T or 3.0 T. Four series of T2-weighted images were generated in total: one set with the ERC signal turned on (ERC) and another set with the ERC signal turned off (Non-ERC). Each of these sets then reconstructed using two different reconstruction methods: conventional reconstruction (Conv) and DL Recon (DLR): ERCDLR, ERCConv, Non-ERCDLR, and Non-ERCConv. Three radiologists independently reviewed and scored the four sets of images for (i) image quality, (ii) artifacts, and (iii) visualization of anatomical landmarks and tumor.
RESULTS: The Non-ERCDLR scored as the best series for (i) overall image quality (p < 0.001), (ii) reduced artifacts (p < 0.001), and (iii) visualization of anatomical landmarks and tumor.
CONCLUSION: Prostate imaging without the use of an endorectal coil could benefit from deep learning reconstruction as demonstrated with T2-weighted imaging MRI evaluations of the prostate.

Entities:  

Keywords:  Cancer; Deep learning; Endorectal coil; Magnetic resonance; Prostate

Mesh:

Year:  2021        PMID: 33580348     DOI: 10.1007/s00261-021-02964-6

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  3 in total

1.  Artificial intelligence based image quality enhancement in liver MRI: a quantitative and qualitative evaluation.

Authors:  Marta Zerunian; Francesco Pucciarelli; Damiano Caruso; Michela Polici; Benedetta Masci; Gisella Guido; Domenico De Santis; Daniele Polverari; Daniele Principessa; Antonella Benvenga; Elsa Iannicelli; Andrea Laghi
Journal:  Radiol Med       Date:  2022-09-07       Impact factor: 6.313

Review 2.  Prostate MRI quality: a critical review of the last 5 years and the role of the PI-QUAL score.

Authors:  Francesco Giganti; Veeru Kasivisvanathan; Alex Kirkham; Shonit Punwani; Mark Emberton; Caroline M Moore; Clare Allen
Journal:  Br J Radiol       Date:  2021-07-08       Impact factor: 3.039

Review 3.  Deep Learning Applications in Magnetic Resonance Imaging: Has the Future Become Present?

Authors:  Sebastian Gassenmaier; Thomas Küstner; Dominik Nickel; Judith Herrmann; Rüdiger Hoffmann; Haidara Almansour; Saif Afat; Konstantin Nikolaou; Ahmed E Othman
Journal:  Diagnostics (Basel)       Date:  2021-11-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.