Literature DB >> 33579908

Hypothermic machine perfusion before viability testing of previously discarded human livers.

Otto B van Leeuwen1, Yvonne de Vries1, Vincent E de Meijer1, Robert J Porte2.   

Abstract

Entities:  

Mesh:

Year:  2021        PMID: 33579908      PMCID: PMC7881206          DOI: 10.1038/s41467-021-21182-8

Source DB:  PubMed          Journal:  Nat Commun        ISSN: 2041-1723            Impact factor:   14.919


× No keyword cloud information.
  15 in total

1.  Viability Criteria for Functional Assessment of Donor Livers During Normothermic Machine Perfusion.

Authors:  Otto B van Leeuwen; Vincent E de Meijer; Robert J Porte
Journal:  Liver Transpl       Date:  2018-10       Impact factor: 5.799

2.  Oxygenated Hypothermic Machine Perfusion After Static Cold Storage Improves Hepatobiliary Function of Extended Criteria Donor Livers.

Authors:  Andrie C Westerkamp; Negin Karimian; Alix P M Matton; Paria Mahboub; Rianne van Rijn; Janneke Wiersema-Buist; Marieke T de Boer; Henri G D Leuvenink; Annette S H Gouw; Ton Lisman; Robert J Porte
Journal:  Transplantation       Date:  2016-04       Impact factor: 4.939

3.  Oxygenated hypothermic machine perfusion after static cold storage improves endothelial function of extended criteria donor livers.

Authors:  Laura C Burlage; Negin Karimian; Andrie C Westerkamp; Nienke Visser; Alix P M Matton; Rianne van Rijn; Jelle Adelmeijer; Janneke Wiersema-Buist; Annette S H Gouw; Ton Lisman; Robert J Porte
Journal:  HPB (Oxford)       Date:  2017-03-25       Impact factor: 3.647

4.  Hypothermic machine preservation in human liver transplantation: the first clinical series.

Authors:  J V Guarrera; S D Henry; B Samstein; R Odeh-Ramadan; M Kinkhabwala; M J Goldstein; L E Ratner; J F Renz; H T Lee; R S Brown; J C Emond
Journal:  Am J Transplant       Date:  2009-12-02       Impact factor: 8.086

5.  HOPE for human liver grafts obtained from donors after cardiac death.

Authors:  Philipp Dutkowski; Andrea Schlegel; Michelle de Oliveira; Beat Müllhaupt; Fabienne Neff; Pierre-Alain Clavien
Journal:  J Hepatol       Date:  2013-12-01       Impact factor: 25.083

6.  Ex vivo normothermic machine perfusion and viability testing of discarded human donor livers.

Authors:  S op den Dries; N Karimian; M E Sutton; A C Westerkamp; M W N Nijsten; A S H Gouw; J Wiersema-Buist; T Lisman; H G D Leuvenink; R J Porte
Journal:  Am J Transplant       Date:  2013-03-06       Impact factor: 8.086

7.  Dual hypothermic oxygenated machine perfusion in liver transplants donated after circulatory death.

Authors:  R van Rijn; N Karimian; A P M Matton; L C Burlage; A C Westerkamp; A P van den Berg; R H J de Kleine; M T de Boer; T Lisman; R J Porte
Journal:  Br J Surg       Date:  2017-04-10       Impact factor: 6.939

8.  Transplantation of high-risk donor livers after resuscitation and viability assessment using a combined protocol of oxygenated hypothermic, rewarming and normothermic machine perfusion: study protocol for a prospective, single-arm study (DHOPE-COR-NMP trial).

Authors:  Yvonne de Vries; Tim A Berendsen; Masato Fujiyoshi; Aad P van den Berg; Hans Blokzijl; Marieke T de Boer; Frans van der Heide; Ruben H J de Kleine; Otto B van Leeuwen; Alix P M Matton; Maureen J M Werner; Ton Lisman; Vincent E de Meijer; Robert Porte
Journal:  BMJ Open       Date:  2019-08-15       Impact factor: 2.692

9.  Biliary Bicarbonate, pH, and Glucose Are Suitable Biomarkers of Biliary Viability During Ex Situ Normothermic Machine Perfusion of Human Donor Livers.

Authors:  Alix P M Matton; Yvonne de Vries; Laura C Burlage; Rianne van Rijn; Masato Fujiyoshi; Vincent E de Meijer; Marieke T de Boer; Ruben H J de Kleine; Henkjan J Verkade; Annette S H Gouw; Ton Lisman; Robert J Porte
Journal:  Transplantation       Date:  2019-07       Impact factor: 4.939

10.  Transplantation of discarded livers following viability testing with normothermic machine perfusion.

Authors:  Hynek Mergental; Richard W Laing; Christina Yap; Simon C Afford; Darius F Mirza; Amanda J Kirkham; M Thamara P R Perera; Yuri L Boteon; Joseph Attard; Darren Barton; Stuart Curbishley; Manpreet Wilkhu; Desley A H Neil; Stefan G Hübscher; Paolo Muiesan; John R Isaac; Keith J Roberts; Manuel Abradelo; Andrea Schlegel; James Ferguson; Hentie Cilliers; Julian Bion; David H Adams; Chris Morris; Peter J Friend
Journal:  Nat Commun       Date:  2020-06-16       Impact factor: 14.919

View more
  4 in total

1.  Identification and treatment of biliary complications after liver transplantation: more relevant than ever.

Authors:  Simon Moosburner; Johann Pratschke; Nathanael Raschzok
Journal:  Hepatobiliary Surg Nutr       Date:  2022-06       Impact factor: 8.265

2.  Utilization of dielectric properties for assessment of liver ischemia-reperfusion injury in vivo and during machine perfusion.

Authors:  Jie Hou; Olav Magnus Ivar Liavåg; Ida Høy Færden; Ørjan Grøttem Martinsen; Tor Inge Tønnessen; Pål-Dag Line; Morten Hagness; Jan Olav Høgetveit; Søren Erik Pischke; Runar Strand-Amundsen
Journal:  Sci Rep       Date:  2022-07-01       Impact factor: 4.996

3.  Reply to 'Hypothermic machine perfusion before viability testing of previously discarded human livers'.

Authors:  Hynek Mergental; Richard W Laing; Simon C Afford; Darius F Mirza
Journal:  Nat Commun       Date:  2021-02-12       Impact factor: 14.919

4.  Sequential hypothermic and normothermic machine perfusion enables safe transplantation of high-risk donor livers.

Authors:  Otto B van Leeuwen; Silke B Bodewes; Veerle A Lantinga; Martijn P D Haring; Adam M Thorne; Isabel M A Brüggenwirth; Aad P van den Berg; Marieke T de Boer; Iris E M de Jong; Ruben H J de Kleine; Bianca Lascaris; Maarten W N Nijsten; Koen M E M Reyntjens; Vincent E de Meijer; Robert J Porte
Journal:  Am J Transplant       Date:  2022-04-18       Impact factor: 9.369