Literature DB >> 33578723

Function of Hemoglobin-Based Oxygen Carriers: Determination of Methemoglobin Content by Spectral Extinction Measurements.

Kathrin Smuda1,2, Jonas Gienger2, Philipp Hönicke2, Jörg Neukammer2.   

Abstract

Suspensions of hemoglobin microparticles (HbMPs) are promising tools as oxygen therapeutics. For the approval of clinical studies extensive characterization of these HbMPs with a size of about 750 nm is required regarding physical properties, function, pharmaco-kinetics and toxicology. The standard absorbance measurements in blood gas analyzers require dissolution of red blood cells which does not work for HbMP. Therefore, we have developed a robust and rapid optical method for the quality and functionality control of HbMPs. It allows simultaneous determination of the portion of the two states of hemoglobin oxygenated hemoglobin (oxyHb) and deoxygenated hemoglobin (deoxyHb) as well as the content of methemoglobin (metHb). Based on the measurement of collimated transmission spectra between 300 nm and 800 nm, the average extinction cross section of HbMPs is derived. A numerical method is applied to determine the composition of the HbMPs based on their wavelength-dependent refractive index (RI), which is a superposition of the three different states of Hb. Thus, light-scattering properties, including extinction cross sections can be simulated for different compositions and sizes. By comparison to measured spectra, the relative concentrations of oxyHb, deoxyHb, metHb are accessible. For validation of the optically determined composition of the HbMPs, we used X-ray fluorescence spectrometry for the ratio of Fe(II) (oxyHb/deoxyHb) and Fe(III) (metHb). High accuracy density measurements served to access heme-free proteins, size was determined by dynamic light scattering and analytical centrifugation and the shape of the HbMPs was visualized by electron and atomic force microscopy.

Entities:  

Keywords:  HbMP; artificial blood substitute; hemoglobin-based oxygen carrier; light scattering; methemoglobin determination; spectral extinction; spectral refractive index; sub-micrometer particle characterization

Mesh:

Substances:

Year:  2021        PMID: 33578723      PMCID: PMC7916497          DOI: 10.3390/ijms22041753

Source DB:  PubMed          Journal:  Int J Mol Sci        ISSN: 1422-0067            Impact factor:   5.923


  29 in total

1.  The ferricyanide method of determining the oxygen capacity of blood.

Authors:  J Haldane
Journal:  J Physiol       Date:  1900-04-24       Impact factor: 5.182

2.  The density increments of proteins.

Authors:  G S ADAIR; M E ADAIR
Journal:  Proc R Soc Lond A Math Phys Sci       Date:  1947-08-12

3.  Nonvasoconstrictive hemoglobin particles as oxygen carriers.

Authors:  Yu Xiong; Zhi Zhao Liu; Radostina Georgieva; Kathrin Smuda; Axel Steffen; Mauricio Sendeski; Andreas Voigt; Andreas Patzak; Hans Bäumler
Journal:  ACS Nano       Date:  2013-08-07       Impact factor: 15.881

Review 4.  How safe is blood, really?

Authors:  Harvey G Klein
Journal:  Biologicals       Date:  2010-01-15       Impact factor: 1.856

5.  Endothelium-derived relaxing factor produced and released from artery and vein is nitric oxide.

Authors:  L J Ignarro; G M Buga; K S Wood; R E Byrns; G Chaudhuri
Journal:  Proc Natl Acad Sci U S A       Date:  1987-12       Impact factor: 11.205

6.  Method of high-precision microsample blood and plasma mass densitometry.

Authors:  H Hinghofer-Szalkay
Journal:  J Appl Physiol (1985)       Date:  1986-03

7.  Hemoglobin-based Oxygen Carriers: Current State-of-the-art and Novel Molecules.

Authors:  Anirban Sen Gupta
Journal:  Shock       Date:  2019-10       Impact factor: 3.454

Review 8.  Red blood cell transfusion: a clinical practice guideline from the AABB*.

Authors:  Jeffrey L Carson; Brenda J Grossman; Steven Kleinman; Alan T Tinmouth; Marisa B Marques; Mark K Fung; John B Holcomb; Orieji Illoh; Lewis J Kaplan; Louis M Katz; Sunil V Rao; John D Roback; Aryeh Shander; Aaron A R Tobian; Robert Weinstein; Lisa Grace Swinton McLaughlin; Benjamin Djulbegovic
Journal:  Ann Intern Med       Date:  2012-07-03       Impact factor: 25.391

Review 9.  A review of blood substitutes: examining the history, clinical trial results, and ethics of hemoglobin-based oxygen carriers.

Authors:  Jiin-Yu Chen; Michelle Scerbo; George Kramer
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

10.  In-vitro haemocompatibility of dextran-protein submicron particles.

Authors:  Chiraphat Kloypan; Nittiya Suwannasom; Saranya Chaiwaree; Ausanai Prapan; Kathrin Smuda; Nuttakorn Baisaeng; Axel Pruß; Radostina Georgieva; Hans Bäumler
Journal:  Artif Cells Nanomed Biotechnol       Date:  2019-12       Impact factor: 5.678

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.