Literature DB >> 33576611

Predictive Modeling of Virus Inactivation by UV.

Nicole C Rockey1, James B Henderson2, Kaitlyn Chin1, Lutgarde Raskin1, Krista R Wigginton1.   

Abstract

UV254 disinfection strategies are commonly applied to inactivate pathogenic viruses in water, food, air, and on surfaces. There is a need for methods that rapidly predict the kinetics of virus inactivation by UV254, particularly for emerging and difficult-to-culture viruses. We conducted a systematic literature review of inactivation rate constants for a wide range of viruses. Using these data and virus characteristics, we developed and evaluated linear and nonlinear models for predicting inactivation rate constants. Multiple linear regressions performed best for predicting the inactivation kinetics of (+) ssRNA and dsDNA viruses, with cross-validated root mean squared relative prediction errors similar to those associated with experimental rate constants. We tested the models by predicting and measuring inactivation rate constants of a (+) ssRNA mouse coronavirus and a dsDNA marine bacteriophage; the predicted rate constants were within 7% and 71% of the experimental rate constants, respectively, indicating that the prediction was more accurate for the (+) ssRNA virus than the dsDNA virus. Finally, we applied our models to predict the UV254 rate constants of several viruses for which high-quality UV254 inactivation data are not available. Our models will be valuable for predicting inactivation kinetics of emerging or difficult-to-culture viruses.

Entities:  

Year:  2021        PMID: 33576611     DOI: 10.1021/acs.est.0c07814

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  3 in total

1.  Ultrafast-UV laser integrating cavity device for inactivation of SARS-CoV-2 and other viruses.

Authors:  Sharad Ambardar; Mark C Howell; Karthick Mayilsamy; Andrew McGill; Ryan Green; Subhra Mohapatra; Dmitri V Voronine; Shyam S Mohapatra
Journal:  Sci Rep       Date:  2022-07-13       Impact factor: 4.996

2.  Ceiling impact on air disinfection performance of Upper-Room Germicidal Ultraviolet (UR-GUV).

Authors:  Shengwei Zhu; Tong Lin; Lingzhe Wang; Edward A Nardell; Richard L Vincent; Jelena Srebric
Journal:  Build Environ       Date:  2022-08-31       Impact factor: 7.093

3.  Modeling the efficiency of UV at 254 nm for disinfecting the different layers within N95 respirators.

Authors:  Abdallatif Satti Abdalrhman; Chengjin Wang; Angelica Manalac; Madrigal Weersink; Abdul-Amir Yassine; Vaughn Betz; Benoit Barbeau; Lothar Lilge; Ron Hofmann
Journal:  J Biophotonics       Date:  2021-07-11       Impact factor: 3.390

  3 in total