Literature DB >> 33570521

In Vitro Evaluation of the Marginal and Internal Accuracy of Different Types of Dental Ceramic Restorations Fabricated Based on Digital and Conventional Impressions.

Halis Özsürmeli, Şebnem Begüm Türker.   

Abstract

PURPOSE: To compare the marginal and internal gap values of different types of ceramic crowns fabricated based on digital and conventional impression methods.
MATERIALS AND METHODS: Ten noncarious extracted human teeth were prepared, and 60 restorations were made using six different impression and fabrication methods. Silicone replicas were obtained for marginal and internal gap evaluation. Statistical analyses were performed using Mann-Whitney U and Kruskal-Wallis tests (P < .05).
RESULTS: Statistically significant differences were found among various impression and fabrication methods. The smallest gap value was shown by the monolithic zirconia indirect digital scanning group (31.13 μm), and the largest for the lithium disilicate indirect digital scanning group (90.09 μm).
CONCLUSION: The marginal and internal gap values of the restorations in the present study were 31.13 to 90.09 μm. The marginal and internal discrepancies of the tested materials were considered clinically acceptable.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33570521     DOI: 10.11607/ijp.6443

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  1 in total

1.  Swirl marks on the internal surface of restorations during mill simulation: A pathway to catastrophic failures.

Authors:  Ilser Turkyilmaz; Gregory Neil Wilkins
Journal:  J Dent Sci       Date:  2021-05-06       Impact factor: 2.080

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.