Literature DB >> 33562505

Optimisation of an Electrochemical DNA Sensor for Measuring KRAS G12D and G13D Point Mutations in Different Tumour Types.

Bukola Attoye1, Matthew J Baker2, Fiona Thomson3, Chantevy Pou3, Damion K Corrigan1.   

Abstract

Circulating tumour DNA (ctDNA) is widely used in liquid biopsies due to having a presence in the blood that is typically in proportion to the stage of the cancer and because it may present a quick and practical method of capturing tumour heterogeneity. This paper outlines a simple electrochemical technique adapted towards point-of-care cancer detection and treatment monitoring from biofluids using a label-free detection strategy. The mutations used for analysis were the KRAS G12D and G13D mutations, which are both important in the initiation, progression and drug resistance of many human cancers, leading to a high mortality rate. A low-cost DNA sensor was developed to specifically investigate these common circulating tumour markers. Initially, we report on some developments made in carbon surface pre-treatment and the electrochemical detection scheme which ensure the most sensitive measurement technique is employed. Following pre-treatment of the sensor to ensure homogeneity, DNA probes developed specifically for detection of the KRAS G12D and G13D mutations were immobilized onto low-cost screen printed carbon electrodes using diazonium chemistry and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride/N-hydroxysuccinimide coupling. Prior to electrochemical detection, the sensor was functionalised with target DNA amplified by standard and specialist PCR methodologies (6.3% increase). Assay development steps and DNA detection experiments were performed using standard voltammetry techniques. Sensitivity (as low as 0.58 ng/μL) and specificity (>300%) was achieved by detecting mutant KRAS G13D PCR amplicons against a background of wild-type KRAS DNA from the representative cancer sample and our findings give rise to the basis of a simple and very low-cost system for measuring ctDNA biomarkers in patient samples. The current time to receive results from the system was 3.5 h with appreciable scope for optimisation, thus far comparing favourably to the UK National Health Service biopsy service where patients can wait for weeks for biopsy results.

Entities:  

Keywords:  DNA biosensors; KRAS; cancer point-of-care diagnostic tests; electrochemical; liquid biopsy

Year:  2021        PMID: 33562505      PMCID: PMC7914712          DOI: 10.3390/bios11020042

Source DB:  PubMed          Journal:  Biosensors (Basel)        ISSN: 2079-6374


  33 in total

1.  Label free aptasensor for Lysozyme detection: A comparison of the analytical performance of two aptamers.

Authors:  Cristina Ocaña; Akhtar Hayat; Rupesh K Mishra; Alina Vasilescu; Manel Del Valle; Jean-Louis Marty
Journal:  Bioelectrochemistry       Date:  2015-05-16       Impact factor: 5.373

Review 2.  Circulating tumor DNA and liquid biopsy: opportunities, challenges, and recent advances in detection technologies.

Authors:  Lena Gorgannezhad; Muhammad Umer; Md Nazmul Islam; Nam-Trung Nguyen; Muhammad J A Shiddiky
Journal:  Lab Chip       Date:  2018-04-17       Impact factor: 6.799

3.  Detection of circulating tumor DNA in early- and late-stage human malignancies.

Authors:  Chetan Bettegowda; Mark Sausen; Rebecca J Leary; Isaac Kinde; Yuxuan Wang; Nishant Agrawal; Bjarne R Bartlett; Hao Wang; Brandon Luber; Rhoda M Alani; Emmanuel S Antonarakis; Nilofer S Azad; Alberto Bardelli; Henry Brem; John L Cameron; Clarence C Lee; Leslie A Fecher; Gary L Gallia; Peter Gibbs; Dung Le; Robert L Giuntoli; Michael Goggins; Michael D Hogarty; Matthias Holdhoff; Seung-Mo Hong; Yuchen Jiao; Hartmut H Juhl; Jenny J Kim; Giulia Siravegna; Daniel A Laheru; Calogero Lauricella; Michael Lim; Evan J Lipson; Suely Kazue Nagahashi Marie; George J Netto; Kelly S Oliner; Alessandro Olivi; Louise Olsson; Gregory J Riggins; Andrea Sartore-Bianchi; Kerstin Schmidt; le-Ming Shih; Sueli Mieko Oba-Shinjo; Salvatore Siena; Dan Theodorescu; Jeanne Tie; Timothy T Harkins; Silvio Veronese; Tian-Li Wang; Jon D Weingart; Christopher L Wolfgang; Laura D Wood; Dongmei Xing; Ralph H Hruban; Jian Wu; Peter J Allen; C Max Schmidt; Michael A Choti; Victor E Velculescu; Kenneth W Kinzler; Bert Vogelstein; Nickolas Papadopoulos; Luis A Diaz
Journal:  Sci Transl Med       Date:  2014-02-19       Impact factor: 17.956

Review 4.  Electrochemical Biosensors - Sensor Principles and Architectures.

Authors:  Dorothee Grieshaber; Robert MacKenzie; Janos Vörös; Erik Reimhult
Journal:  Sensors (Basel)       Date:  2008-03-07       Impact factor: 3.576

5.  Comparison of false positive rates for screening breast magnetic resonance imaging (MRI) in high risk women performed on stacked versus alternating schedules.

Authors:  Edress Othman; Jue Wang; Brian L Sprague; Tiffany Rounds; YongLi Ji; Sally D Herschorn; Marie E Wood
Journal:  Springerplus       Date:  2015-02-13

Review 6.  Risk of tumor cell seeding through biopsy and aspiration cytology.

Authors:  K Shyamala; H C Girish; Sanjay Murgod
Journal:  J Int Soc Prev Community Dent       Date:  2014-01

7.  Pancreatic cancer: Circulating Tumor Cells and Primary Tumors show Heterogeneous KRAS Mutations.

Authors:  Birte Kulemann; Stephanie Rösch; Sindy Seifert; Sylvia Timme; Peter Bronsert; Gabriel Seifert; Verena Martini; Jasmina Kuvendjiska; Torben Glatz; Saskia Hussung; Ralph Fritsch; Heiko Becker; Martha B Pitman; Jens Hoeppner
Journal:  Sci Rep       Date:  2017-07-03       Impact factor: 4.379

8.  Plasma cell-free DNA quantification is highly correlated to tumor burden in children with neuroblastoma.

Authors:  Xisi Wang; Lijun Wang; Yan Su; Zhixia Yue; Tianyu Xing; Wen Zhao; Qian Zhao; Chao Duan; Cheng Huang; Dawei Zhang; Mei Jin; Xianfeng Cheng; Shenglan Chen; Yi Liu; Xiaoli Ma
Journal:  Cancer Med       Date:  2018-06-14       Impact factor: 4.452

Review 9.  Grafting of Diazonium Salts on Surfaces: Application to Biosensors.

Authors:  Dardan Hetemi; Vincent Noël; Jean Pinson
Journal:  Biosensors (Basel)       Date:  2020-01-15

10.  Developing a Low-Cost, Simple-to-Use Electrochemical Sensor for the Detection of Circulating Tumour DNA in Human Fluids.

Authors:  Bukola Attoye; Chantevy Pou; Ewen Blair; Christopher Rinaldi; Fiona Thomson; Matthew J Baker; Damion K Corrigan
Journal:  Biosensors (Basel)       Date:  2020-10-28
View more
  2 in total

1.  Rapid Multiplex Strip Test for the Detection of Circulating Tumor DNA Mutations for Liquid Biopsy Applications.

Authors:  Panagiota M Kalligosfyri; Sofia Nikou; Sofia Karteri; Haralabos P Kalofonos; Vasiliki Bravou; Despina P Kalogianni
Journal:  Biosensors (Basel)       Date:  2022-02-04

2.  Reverse Electrochemical Sensing of FLT3-ITD Mutations in Acute Myeloid Leukemia Using Gold Sputtered ZnO-Nanorod Configured DNA Biosensors.

Authors:  Ramesh Thevendran; Kai Loong Foo; Mohd Hazwan Hussin; Emmanuel Jairaj Moses; Marimuthu Citartan; Haarindraprasad Rajintra Prasad; Solayappan Maheswaran
Journal:  Biosensors (Basel)       Date:  2022-03-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.