Junya Itou1, Umito Kuwashima1, Masafumi Itoh1, Koichi Kuroda2, Yasuharu Yokoyama2, Ken Okazaki3. 1. Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan. 2. Olympus Terumo Biomaterials Corp., Sasazuka NA Bldg., 1-50-1 Sasazuka, Shibuya-ku, Tokyo, 151-0073, Japan. 3. Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan. okazaki.ken@twmu.ac.jp.
Abstract
BACKGROUND: The neurovascular bundle containing the deep peroneal nerve has a potential risk of injury during open-wedge high tibial osteotomy (OWHTO), particularly due to drilling for bicortical fixation at distal screw holes. Therefore, monocortical fixation is recommended for distal fixation of a long locking plate as long as good stability is ensured. The purpose of this study was to analyse the biomechanical properties of monocortical fixation of distal locking screws for OWHTO. METHODS: Three-dimensional models of bone and fixation materials simulating OWHTO were created using computed tomographic data of patients and material data of a T-shaped long locking plate and screws. Three of the four distal screws of the locking plate were chosen for a bicortical fixation or monocortical fixation procedure. In addition, loss of correction was assessed by measuring the medial proximal tibial angle (MPTA) in patients who underwent OWHTO with two bicortical and two monocortical distal fixation screws at 1 month and 1 year after surgery. RESULTS: No significant differences in stress were observed in either the normal or osteoporotic bone model between the monocortical and bicortical fixation models, including in the area of the lateral hinge at the osteotomy site. Furthermore, there were no significant differences in MPTA between the early post-operative period and 1-year follow-up. CONCLUSIONS: The monocortical fixation method for three distal screws of the locking plate did not worsen the mechanical properties of fixation for OWHTO using a long locking plate with four proximal and four distal screws. In actual surgery, the number of distal bicortical screws should be reduced based on the patient's condition, taking into account the risk of lateral hinge fracture and unexpected surgical complications. Using at least two bicortical screws would be practical considering the various factors related to reduced fixing ability.
BACKGROUND: The neurovascular bundle containing the deep peroneal nerve has a potential risk of injury during open-wedge high tibial osteotomy (OWHTO), particularly due to drilling for bicortical fixation at distal screw holes. Therefore, monocortical fixation is recommended for distal fixation of a long locking plate as long as good stability is ensured. The purpose of this study was to analyse the biomechanical properties of monocortical fixation of distal locking screws for OWHTO. METHODS: Three-dimensional models of bone and fixation materials simulating OWHTO were created using computed tomographic data of patients and material data of a T-shaped long locking plate and screws. Three of the four distal screws of the locking plate were chosen for a bicortical fixation or monocortical fixation procedure. In addition, loss of correction was assessed by measuring the medial proximal tibial angle (MPTA) in patients who underwent OWHTO with two bicortical and two monocortical distal fixation screws at 1 month and 1 year after surgery. RESULTS: No significant differences in stress were observed in either the normal or osteoporotic bone model between the monocortical and bicortical fixation models, including in the area of the lateral hinge at the osteotomy site. Furthermore, there were no significant differences in MPTA between the early post-operative period and 1-year follow-up. CONCLUSIONS: The monocortical fixation method for three distal screws of the locking plate did not worsen the mechanical properties of fixation for OWHTO using a long locking plate with four proximal and four distal screws. In actual surgery, the number of distal bicortical screws should be reduced based on the patient's condition, taking into account the risk of lateral hinge fracture and unexpected surgical complications. Using at least two bicortical screws would be practical considering the various factors related to reduced fixing ability.
Entities:
Keywords:
Finite element analysis; Monocortical fixation; Open-wedge high tibial osteotomy
Authors: Henning Madry; Lars Goebel; Alexander Hoffmann; Klaus Dück; Torsten Gerich; Romain Seil; Thomas Tschernig; Dietrich Pape Journal: Knee Surg Sports Traumatol Arthrosc Date: 2016-05-28 Impact factor: 4.342