Literature DB >> 3355461

Current and emerging technology in G-LOC detection: noninvasive monitoring of cerebral microcirculation using near infrared.

D H Glaister1.   

Abstract

G-induced loss of consciousness (G-LOC) has emerged as an important operational problem of high-performance aircraft. Since it appears that G-LOC will continue to be a problem, a requirement exists to detect its occurrence in pilots so that the aircraft may be placed on autopilot. One excellent method of detecting G-LOC physiologically, one would assume, would be based on the oxidative status of the brain. This determination can be made noninvasively with an Oxidative Metabolism Near-Infrared monitor using 4 wave lengths (OMNI-4). The OMNI-4 is capable of measuring the relative quantities in the brain of hemoglobin (Hb), oxygenated hemoglobin (HbO2), blood volume (BV), and oxidative status of cytochrome c oxidase. This instrument was tested on subjects in the USAFSAM human-use centrifuge at +3, 4, and 5 Gz with onset rates of 1 G.s-1. Results showed changes within the brain, as expected, during increased G with reductions in Hb, BV, and HbO2. Cytochrome c oxidase measurements were inconclusive. Immediately following G exposure, Hb, BV, and HbO2 "overshoots" occurred suggesting vasodilation of the cerebral microcirculation. The use of OMNI-4 in the laboratory and its possible role as a detector of G-LOC in pilots are discussed including suggestions for future developments.

Entities:  

Mesh:

Year:  1988        PMID: 3355461

Source DB:  PubMed          Journal:  Aviat Space Environ Med        ISSN: 0095-6562


  4 in total

Review 1.  Future applications of lasers in surgery and medicine: a review.

Authors:  D H Sliney; M L Wolbarsht
Journal:  J R Soc Med       Date:  1989-05       Impact factor: 18.000

2.  A new evaluation method for +Gz tolerance with loratadine by using a near-infrared spectroscopy.

Authors:  Akihiko Onozawa; Azusa Kikukawa; Yoshinori Miyamoto
Journal:  Dyn Med       Date:  2008-01-28

3.  Monitoring of pre-frontal oxygen status in helicopter pilots using near-infrared spectrophotometers.

Authors:  Asao Kobayashi; Yoshinori Miyamoto; Azusa Kikukawa
Journal:  Dyn Med       Date:  2008-07-11

4.  Broadband NIRS Cerebral Evaluation of the Hemodynamic and Oxidative State of Cytochrome-c-Oxidase Responses to +Gz Acceleration in Healthy Volunteers.

Authors:  F Lange; G Bale; P Kaynezhad; R D Pollock; A Stevenson; I Tachtsidis
Journal:  Adv Exp Med Biol       Date:  2020       Impact factor: 3.650

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.