Literature DB >> 33553698

Maintaining consistent bladder filling during external beam radiotherapy for prostate cancer.

Nicola J Nasser1, Eyal Fenig2, Jonathan Klein3, Abed Agbarya4.   

Abstract

Radiation therapy for patients with prostate cancer is preferably provided with a full urinary bladder. Full bladder can potentially move the small intestine out of the radiation treatment regions, and results in decreased small bowel radiation dose and gastrointestinal toxicity. Maintaining consistent bladder filling during computerized tomography simulation scan used for treatment planning and at daily radiation treatments is challenging. Here we present an in-development urinary catheter with a floating balloon that drains the bladder only when urine reaches to a prespecified level, and review current methods used in clinic to ensure consistent bladder filling. These includes bladder filling protocols, ultrasound scanning and biofeedback techniques.
© 2021 The Authors.

Entities:  

Keywords:  Bladder filling; Check valve; Float; Prostate cancer; Radiation therapy; Urinary catheter

Year:  2021        PMID: 33553698      PMCID: PMC7851838          DOI: 10.1016/j.tipsro.2021.01.002

Source DB:  PubMed          Journal:  Tech Innov Patient Support Radiat Oncol        ISSN: 2405-6324


  22 in total

1.  Assessing the daily consistency of bladder filling using an ultrasonic Bladderscan device in men receiving radical conformal radiotherapy for prostate cancer.

Authors:  S Hynds; C K McGarry; D M Mitchell; S Early; L Shum; D P Stewart; J A Harney; C R Cardwell; J M O'Sullivan
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

2.  Bladder filling variation during radiation treatment of prostate cancer: can the use of a bladder ultrasound scanner and biofeedback optimize bladder filling?

Authors:  Marcel R Stam; Emile N J Th van Lin; Lisette P van der Vight; Johannes H A M Kaanders; Andries G Visser
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-03-15       Impact factor: 7.038

3.  Stereotactic Body Radiation Therapy for Localized Prostate Cancer: A Systematic Review and Meta-Analysis of Over 6,000 Patients Treated On Prospective Studies.

Authors:  William C Jackson; Jessica Silva; Holly E Hartman; Robert T Dess; Amar U Kishan; Whitney H Beeler; Laila A Gharzai; Elizabeth M Jaworski; Rohit Mehra; Jason W D Hearn; Todd M Morgan; Simpa S Salami; Matthew R Cooperberg; Brandon A Mahal; Payal D Soni; Samuel Kaffenberger; Paul L Nguyen; Neil Desai; Felix Y Feng; Zachary S Zumsteg; Daniel E Spratt
Journal:  Int J Radiat Oncol Biol Phys       Date:  2019-04-06       Impact factor: 7.038

4.  The implementation of an empty bladder filling protocol for localised prostate volumetric modulated arctherapy (VMAT): early results of a single institution service evaluation.

Authors:  Gayan Chetiyawardana; Peter J Hoskin; Yat Man Tsang
Journal:  Br J Radiol       Date:  2020-07-31       Impact factor: 3.039

5.  Once-weekly versus every-other-day stereotactic body radiotherapy in patients with prostate cancer (PATRIOT): A phase 2 randomized trial.

Authors:  Harvey C Quon; Aldrich Ong; Patrick Cheung; William Chu; Hans T Chung; Danny Vesprini; Amit Chowdhury; Dilip Panjwani; Geordi Pang; Renee Korol; Melanie Davidson; Ananth Ravi; Boyd McCurdy; Liying Zhang; Alexandre Mamedov; Andrea Deabreu; Andrew Loblaw
Journal:  Radiother Oncol       Date:  2018-03-15       Impact factor: 6.280

6.  Interfraction prostate displacement during image-guided radiotherapy using intraprostatic fiducial markers and a cone-beam computed tomography system: A volumetric off-line analysis in relation to the variations of rectal and bladder volumes.

Authors:  Gianluca Ingrosso; Roberto Miceli; Elisabetta Ponti; Andrea Lancia; Daniela di Cristino; Francesco de Pasquale; Pierluigi Bove; Riccardo Santoni
Journal:  J Cancer Res Ther       Date:  2019-03       Impact factor: 1.805

7.  Stereotactic body radiotherapy to the prostate and pelvic lymph nodes: A detailed dosimetric analysis of a phase II prospective trial.

Authors:  Amar U Kishan; Marguerite Tyran; Julius Weng; Shrinivasa Upadhyaya; James Lamb; Michael Steinberg; Christopher King; Minsong Cao
Journal:  Br J Radiol       Date:  2019-04-03       Impact factor: 3.039

8.  Impact of bladder volume on acute genitourinary toxicity in intensity modulated radiotherapy for localized and locally advanced prostate cancer.

Authors:  Arne Grün; Michael Kawgan-Kagan; David Kaul; Harun Badakhshi; Carmen Stromberger; Volker Budach; Dirk Böhmer
Journal:  Strahlenther Onkol       Date:  2018-11-15       Impact factor: 3.621

9.  Assessment of inter- and intra-fractional volume of bladder and body contour by mega-voltage computed tomography in helical tomotherapy for pelvic malignancy.

Authors:  Sunghyun Kim; Sei Hwan You; Young Ju Eum
Journal:  Radiat Oncol J       Date:  2018-09-30

10.  The impact of bladder preparation protocols on post treatment toxicity in radiotherapy for localised prostate cancer patients.

Authors:  Yat Man Tsang; Peter Hoskin
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2017-11-02
View more
  2 in total

1.  Augmented reality-guided positioning system for radiotherapy patients.

Authors:  Chunying Li; Zhengda Lu; Mu He; Jianfeng Sui; Tao Lin; Kai Xie; Jiawei Sun; Xinye Ni
Journal:  J Appl Clin Med Phys       Date:  2022-01-05       Impact factor: 2.102

2.  Automatic localization of the prostatic urethra for image guided radiation therapy.

Authors:  Nicola J Nasser; Jonathan Klein; Eyal Fenig; Abed Agbarya
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2021-06-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.