Literature DB >> 33553239

Determination of the Optimum Excitation Wavelength for the Parathyroid Gland Using a Near-Infrared Camera.

Isao Tabei1,2, Azusa Fuke1,2, Astushi Fushimi2, Hiroshi Takeyama2.   

Abstract

When performing thyroid/parathyroid surgery, difficulty detecting the parathyroid gland is a common experience because it is frequently mistaken with surrounding structures, including the thyroid gland, lymph nodes, and fat. To obtain successful surgical results, the auto fluorescent property of the parathyroid gland occurring at 820-830 nm has been used. Intraoperative visualization and detection by fluorescence enable protection of the gland from damage and unintended removal. Use of a near-infrared (NIR) camera has been proposed to indicate the parathyroid gland, but the devices and success rates have varied. This study aimed to define optimum excitation wavelength (EWL) by measuring the EWL of the parathyroid gland for its autofluorescence. Glands were exposed to EWL at 10-nm intervals from 670-790 nm with a light-emitting diode monochromator; autofluorescence intensity was recorded with a conventional NIR video camera. Autofluorescence intensity curves of three normal parathyroid glands were depicted; the optimum EWL was measured as 760-770 nm. Also, the illumination of the surrounding structures were compared at the optimum EWL. The auto fluorescent intensity of the parathyroid gland was 2-fold greater than for surrounding structures. This difference in fluorescence intensity should enable distinction of the parathyroid gland from surrounding structures. The clarification of the optimum EWL can guide refinements of the NIR camera for better surgical outcomes by improving detection of the parathyroid glands. Also, an understanding of optimum EWL should lead to developments for microscopic devices to unravel the still unknown mechanisms of the intrinsic autofluorescence of the parathyroid gland.
Copyright © 2021 Tabei, Fuke, Fushimi and Takeyama.

Entities:  

Keywords:  ICG; autofluorescence; excitation wavelength; near-infrared camera; parathyroid gland

Year:  2021        PMID: 33553239      PMCID: PMC7859514          DOI: 10.3389/fsurg.2020.619859

Source DB:  PubMed          Journal:  Front Surg        ISSN: 2296-875X


  21 in total

Review 1.  Surgeon's approach to the thyroid gland: surgical anatomy and the importance of technique.

Authors:  R D Bliss; P G Gauger; L W Delbridge
Journal:  World J Surg       Date:  2000-08       Impact factor: 3.352

2.  Fluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancer.

Authors:  Toshiyuki Kitai; Takuya Inomoto; Mitsuharu Miwa; Takahiro Shikayama
Journal:  Breast Cancer       Date:  2005       Impact factor: 4.239

3.  Usefulness of intraoperative 99m Tc-MIBI-guided detection for recurrent sites in secondary hyperparathyroidism: a case-controlled study.

Authors:  Hiroshi Takeyama; Isao Tabei; Shigeyuki Ogi; Keitaro Yokoyama; Hiroyasu Yamamoto; Ichiro Okido; Satoki Kinoshita; Hideaki Kurihara; Kazuhiko Yoshida; Ken Uchida; Toshiaki Morikawa
Journal:  Int J Surg       Date:  2008-03-02       Impact factor: 6.071

4.  Increased identification of parathyroid glands using near infrared light during thyroid and parathyroid surgery.

Authors:  Jorge Falco; Fernando Dip; Pablo Quadri; Martin de la Fuente; Marcos Prunello; Raúl J Rosenthal
Journal:  Surg Endosc       Date:  2017-03-31       Impact factor: 4.584

5.  Label-free intraoperative parathyroid localization with near-infrared autofluorescence imaging.

Authors:  Melanie A McWade; Constantine Paras; Lisa M White; John E Phay; Carmen C Solórzano; James T Broome; Anita Mahadevan-Jansen
Journal:  J Clin Endocrinol Metab       Date:  2014-12       Impact factor: 5.958

6.  Prospective evaluation of intra-operative quick parathyroid hormone assay as an early predictor of post thyroidectomy hypocalcaemia.

Authors:  Ashwini C Reddy; Gyan Chand; M Sabaretnam; Anjali Mishra; Gaurav Agarwal; Amit Agarwal; A K Verma; S K Mishra
Journal:  Int J Surg       Date:  2016-08-12       Impact factor: 6.071

7.  Indocyanine green fluorescence imaging to reduce the risk of anastomotic leakage in laparoscopic low anterior resection for rectal cancer: a propensity score-matched cohort study.

Authors:  Jun Watanabe; Atsushi Ishibe; Yusuke Suwa; Hirokazu Suwa; Mitsuyoshi Ota; Chikara Kunisaki; Itaru Endo
Journal:  Surg Endosc       Date:  2019-03-14       Impact factor: 4.584

8.  Importance of in situ preservation of parathyroid glands during total thyroidectomy.

Authors:  L Lorente-Poch; J J Sancho; S Ruiz; A Sitges-Serra
Journal:  Br J Surg       Date:  2015-01-20       Impact factor: 6.939

9.  Feasibility of indocyanine green fluorescence imaging for intraoperative identification of parathyroid glands during thyroid surgery.

Authors:  Jacqueline van den Bos; Lottie van Kooten; Sanne M E Engelen; Tim Lubbers; Laurents P S Stassen; Nicole D Bouvy
Journal:  Head Neck       Date:  2018-12-11       Impact factor: 3.147

10.  A review of indocyanine green fluorescent imaging in surgery.

Authors:  Jarmo T Alander; Ilkka Kaartinen; Aki Laakso; Tommi Pätilä; Thomas Spillmann; Valery V Tuchin; Maarit Venermo; Petri Välisuo
Journal:  Int J Biomed Imaging       Date:  2012-04-22
View more