Literature DB >> 33550346

[Measurement of the weight and volume of submandibular gland in vitro].

Y P Wang1, Z G Cai1, X Peng1, J Zhang1, Z P Sun2, W Li1, L Zhang1, G Y Yu1.   

Abstract

OBJECTIVE: To measure the weight and volume of normal submandibular gland by in vitro detection of glandular body, to compare with the measurement values of CT volume rendering to evaluate the consistency of the two methods, and to explore the related factors affecting the weight and volume of the submandibular gland.
METHODS: The patients who underwent neck dissection due to oral cancer and were confirmed with normal submandibular gland by postoperative histopathology in Peking University School and Hospital of Stomatology from May 2019 to January 2020 were collected in this study and divi-ded into 4 groups according to the age standards raised by the Society of Geriatrics Chinese Medical Association and WHO (2000) age standards. The submandibular gland was carefully dissected along with the capsule immediately after neck dissection. The weight and volume of submandibular gland were accurately measured by an integrated aseptic measuring device. The volume of submandibular gland was measured by CT volume rendering before operation and the consistency of the two methods was evaluated. The 95% confidence interval of the weight and volume of submandibular gland in the different groups of Chinese people, which were divided by gender and age, were calculated, and the correlation with age, gender, height, weight, body mass index (BMI) and other factors was analyzed.
RESULTS: The weight and vo-lume of submandibular gland were measured in 220 subjects. The average weight and volume of submandibular gland were (11.69±2.45) g and (11.55±2.41) cm3 respectively. The volume of submandibular gland measured by CT volume rendering ranged from 70% to 82% of that measured by in vitro detection of glandular body, and the correlation coefficient between the two methods was 0.976 (P < 0.05). The gender difference of weight and volume of submandibular gland existed in the groups of youth, middle-aged, young elderly and elderly groups, the values of males were obviously higher than those of females (P < 0.05). There was no gender difference of weight and volume of submandibular gland in the adolescent group (P > 0.05). The weight and volume of submandibular gland had a strong positive correlation with body height (P < 0.05), a weak positive correlation with body weight (P < 0.05), and no correlation with BMI (P > 0.05). The female's weight and volume of submandibular gland in the young elderly and elderly groups were significantly lower than those in the other three groups (P < 0.05).
CONCLUSION: The normal reference range of the weight and volume of submandibular gland in vitro were established in different age and gender groups of Chinese people. The volume of submandibular gland mea-sured by CT volume rendering was 70%-82% of that measured by in vitro detection of glandular body. The results of the two methods had a high degree of consistency. The weight and volume of submandibular gland were related to age, gender, body height and body weight.

Entities:  

Keywords:  CT volume rendering; Submandibular gland; Volume; Weight

Mesh:

Year:  2020        PMID: 33550346      PMCID: PMC7867988     

Source DB:  PubMed          Journal:  Beijing Da Xue Xue Bao Yi Xue Ban        ISSN: 1671-167X


  5 in total

1.  Quantitative analysis of normal major salivary glands using computed tomography.

Authors:  M S Heo; S C Lee; S S Lee; H M Choi; S C Choi; T W Park
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2001-08

2.  Radiologic measurement of submandibular gland ptosis.

Authors:  Matthew Kun Lee; Ali Sepahdari; Marc Cohen
Journal:  Facial Plast Surg       Date:  2013-07-24       Impact factor: 1.446

3.  Planimetric correlation between the submandibular glands and the pancreas: a postmortem ductographic study.

Authors:  Bojan V Stimec; Zoran Rakocevic; Dejan Ignjatovic; Jean H D Fasel
Journal:  Anat Sci Int       Date:  2016-11-10       Impact factor: 1.741

4.  Three-dimensional ultrasound measurement of cervical lymph node volume.

Authors:  M Ying; B S F Pang
Journal:  Br J Radiol       Date:  2009-01-19       Impact factor: 3.039

5.  Volume assessment accuracy in computed tomography: a phantom study.

Authors:  Nicolas D Prionas; Shonket Ray; John M Boone
Journal:  J Appl Clin Med Phys       Date:  2010-04-16       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.