Literature DB >> 33549900

Comparison of reduced field-of-view diffusion-weighted imaging (DWI) and conventional DWI techniques in the assessment of Cervical carcinoma at 3.0T: Image quality and FIGO staging.

Mingzhen Chen1, Cui Feng1, Qiuxia Wang1, Jiali Li1, Sisi Wu1, Daoyu Hu1, Baodi Deng2, Zhen Li1.   

Abstract

OBJECTIVE: To evaluate imaging quality (IQ) and International Federation of Gynecology and Obstetrics (FIGO) staging of reduced field-of-view (r-FOV) diffusion-weighted imaging (DWI) in cervical carcinoma (CC).
MATERIALS AND METHODS: Sixty patients with pathologically proven CC who underwent both pre-treatment r-FOV DWI and full field-of-view (f-FOV) DWI on a 3.0T MRI scanner were retrospectively reviewed. The subjective qualitative image scores were compared using the Wilcoxon signed-rank test. Objective quality values and apparent diffusion coefficient (ADC) were estimated by paired t-test or Wilcoxon signed-rank test for the two DWI sequences according to Normality test. Spearman rank correlation analysis was used to evaluate the relationship between pathological results and mean ADC value.
RESULTS: The subjective IQ scores for r-FOV DWI were significantly higher than those for f-FOV DWI (P < 0.001). Similarly, the contrast-to-noise (CNR) value of r-FOV DWI was superior to that of f-FOV DWI (10.30 ± 3.676, 8.91 ± 3.008, P = 0.021). However, the signal-to-noise ratio (SNR) value of r-FOV DWI was considerably lower than that of f-FOV DWI (27.80 ± 6.056, 33.67 ± 7.833, P<0.001). No significant difference was found between mean ADC values of f-FOV DWI and r-FOV DWI. There was a significant tendency for a negative correlation between the ADC values and FIGO stages of CC for both two sequences (r=-0. 436, P<0.01; r=-0.470, P<0.01, respectively).
CONCLUSIONS: The rFOV DWI sequence provided significantly better IQ and lesion conspicuity than the fFOV DWI sequence. In addition, rFOV sequences can be used in evaluation of FIGO staging of cervical cancer.
Copyright © 2021. Published by Elsevier B.V.

Entities:  

Keywords:  Cervical carcinoma; Diffusion-weighted imaging; Full field-of-view; Image quality; Reduced field-of-view

Mesh:

Year:  2021        PMID: 33549900     DOI: 10.1016/j.ejrad.2021.109557

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  3 in total

1.  The feasibility of reduced field-of-view diffusion-weighted imaging in evaluating bladder invasion of uterine cervical cancer.

Authors:  Mayumi Takeuchi; Kenji Matsuzaki; Masafumi Harada
Journal:  Br J Radiol       Date:  2021-10-27       Impact factor: 3.039

2.  The value of whole-lesion histogram analysis based on field‑of‑view optimized and constrained undistorted single shot (FOCUS) DWI for predicting axillary lymph node status in early-stage breast cancer.

Authors:  Shu Fang; Jun Zhu; Yafeng Wang; Jie Zhou; Guiqian Wang; Weiwei Xu; Wei Zhang
Journal:  BMC Med Imaging       Date:  2022-09-10       Impact factor: 2.795

3.  Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T.

Authors:  Wenguang Liu; Hui Liu; Simin Xie; Ismail Bilal Masokano; Yu Bai; Xiao Wang; Linhui Zhong; Yi Wu; Jilin Nie; Gaofeng Zhou; Yigang Pei; Wenzheng Li
Journal:  Sci Rep       Date:  2022-07-20       Impact factor: 4.996

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.