Application of combined model of stepwise regression analysis and artificial neural network in data calibration of miniature air quality detector.

Bing Liu1, Qingbo Zhao2, Yueqiang Jin3, Jiayu Shen3, Chaoyang Li4.   

Abstract

In this paper, six types of air pollutant concentrations are taken as the research object, and the data monitored by the micro air quality detector are calibrated by the national control point measurement data. We use correlation analysis to find out the main factors affecting air quality, and then build a stepwise regression model for six types of pollutants based on 8 months of data. Taking the stepwise regression fitting value and the data monitored by the miniature air quality detector as input variables, combined with the multilayer perceptron neural network, the SRA-MLP model was obtained to correct the pollutant data. We compared the stepwise regression model, the standard multilayer perceptron neural network and the SRA-MLP model by three indicators. Whether it is root mean square error, average absolute error or average relative error, SRA-MLP model is the best model. Using the SRA-MLP model to correct the data can increase the accuracy of the self-built point data by 42.5% to 86.5%. The SRA-MLP model has excellent prediction effects on both the training set and the test set, indicating that it has good generalization ability. This model plays a positive role in scientific arrangement and promotion of miniature air quality detectors. It can be applied not only to air quality monitoring, but also to the monitoring of other environmental indicators.

Entities:  

Year:  2021        PMID: 33547414     DOI: 10.1038/s41598-021-82871-4

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  3 in total

1.  Calibration of miniature air quality detector monitoring data with PCA-RVM-NAR combination model.

Authors:  Bing Liu; Yirui Zhang
Journal:  Sci Rep       Date:  2022-06-04       Impact factor: 4.996

2.  A data calibration method for micro air quality detectors based on a LASSO regression and NARX neural network combined model.

Authors:  Bing Liu; Yueqiang Jin; Dezhi Xu; Yishu Wang; Chaoyang Li
Journal:  Sci Rep       Date:  2021-10-27       Impact factor: 4.379

3.  Application of RR-XGBoost combined model in data calibration of micro air quality detector.

Authors:  Bing Liu; Xianghua Tan; Yueqiang Jin; Wangwang Yu; Chaoyang Li
Journal:  Sci Rep       Date:  2021-08-02       Impact factor: 4.379