Literature DB >> 33545818

A novel electrochemical platform based on mesoporous silica/titania and gold nanoparticles for simultaneous determination of norepinephrine and dopamine.

Franciele de Matos Morawski1, Brenda Borges Xavier1, Anike Hübner Virgili1, Karine Dos Santos Caetano1, Eliana Weber de Menezes1, Edilson Valmir Benvenutti1, Tania Maria Haas Costa1, Leliz Ticona Arenas2.   

Abstract

An amorphous and mesoporous silica/titania (SiTi) material was synthesized by sol-gel method and its surface was modified with gold nanoparticles (AuNP) previously stabilized in a chitosan solution. The presence of small AuNP, with diameter lower than 10 nm was confirmed by transmission electron microscopy (TEM) and UV-Vis spectroscopy. Carbon paste electrodes were prepared to test the electrochemical properties by using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) in [Fe(CN)6]3-/4- solution probe whereby the material silica-titania/gold nanoparticles (SiTi/AuNP) showed a huge improvement in the redox peak current and low charge transfer resistance. This electrode presented a good response for both norepinephrine and dopamine by means of square wave voltammetry (SWV) measurements; great sensitivity for both analytes, in an extensive linear range, was obtained. The limits of detection were 0.35 μmol L-1 and 0.57 μmol L-1 for norepinephrine and dopamine, respectively. Additionally, this electrode showed high selectivity for both analytes and it was applied in the simultaneous determination of norepinephrine and dopamine. The sensor was also tested in simulated biological fluids presenting a good recovery. The SWV electrochemical response of norepinephrine was also investigated in the presence of possible interferers such as uric acid, ascorbic acid and glucose and there was no significant interference. The prepared electrode also exhibits good reproducibility for norepinephrine detection, with relative standard deviation of 5.19%.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Catecholamine; Chitosan; Electrochemical sensor; Nanocomposite; Neurotransmitters; Square wave voltammetry

Mesh:

Substances:

Year:  2020        PMID: 33545818     DOI: 10.1016/j.msec.2020.111646

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  2 in total

Review 1.  Point-of-care biochemical assays using electrochemical technologies: approaches, applications, and opportunities.

Authors:  Qihong Ning; Shaoqing Feng; Yuemeng Cheng; Tangan Li; Daxiang Cui; Kan Wang
Journal:  Mikrochim Acta       Date:  2022-08-02       Impact factor: 6.408

2.  Tailoring Mesoporous Titania Features by Ultrasound-Assisted Sol-Gel Technique: Effect of Surfactant/Titania Precursor Weight Ratio.

Authors:  Elvira Mahu; Cristina Giorgiana Coromelci; Doina Lutic; Iuliean Vasile Asaftei; Liviu Sacarescu; Valeria Harabagiu; Maria Ignat
Journal:  Nanomaterials (Basel)       Date:  2021-05-11       Impact factor: 5.076

  2 in total