Literature DB >> 33540572

The Simulated Characterization and Suitability of Semiconductor Detectors for Strontium 90 Assay in Groundwater.

Graeme Turkington1, Kelum A A Gamage1, James Graham2.   

Abstract

This paper examines the potential deployment of a 10 mm × 10 mm × 1 mm cadmium telluride detector for strontium-90 measurement in groundwater boreholes at nuclear decommissioning sites. Geant4 simulation was used to model the deployment of the detector in a borehole monitoring contaminated groundwater. It was found that the detector was sensitive to strontium-90, yttrium-90, caesium-137, and potassium-40 decay, some of the significant beta emitters found at Sellafield. However, the device showed no sensitivity to carbon-14 decay, due to the inability of the weak beta emission to penetrate both the groundwater and the detector shielding. The limit of detection for such a sensor when looking at solely strontium-90 decay was calculated as 323 BqL-1 after a 1-h measurement and 66 BqL-1 after a 24-h measurement. A gallium-arsenide (GaAs) sensor with twice the surface area, but 0.3% of the thickness was modelled for comparison. Using this sensor, sensitivity was increased, such that the limit of detection for strontium-90 was 91 BqL-1 after 1 h and 18 BqL-1 after 24 h. However, this sensor sacrifices the potential to identify the present radionuclides by their end-point energy. Additionally, the feasibility of using flexible detectors based on solar cell designs to maximise the surface area of detectors has been modelled.

Entities:  

Keywords:  cadmium-telluride; decommissioning; detectors; geant4 simulation; radiation; strontium-90

Year:  2021        PMID: 33540572      PMCID: PMC7867158          DOI: 10.3390/s21030984

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  4 in total

1.  Determination of radiostrontium isotopes: a review of analytical methodology.

Authors:  Nóra Vajda; Chang-Kyu Kim
Journal:  Appl Radiat Isot       Date:  2010-06-01       Impact factor: 1.513

2.  Investigation of 3H, 99Tc, and 90Sr transport in fractured rock and the effects of fracture-filling/coating material at LILW disposal facility.

Authors:  Won-Seok Kim; Sangsoo Han; Jinmo Ahn; Wooyong Um
Journal:  Environ Geochem Health       Date:  2018-05-23       Impact factor: 4.609

3.  Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications.

Authors:  Stefano Del Sordo; Leonardo Abbene; Ezio Caroli; Anna Maria Mancini; Andrea Zappettini; Pietro Ubertini
Journal:  Sensors (Basel)       Date:  2009-05-12       Impact factor: 3.576

Review 4.  A Review: Photonic Devices Used for Dosimetry in Medical Radiation.

Authors:  Edrine Damulira; Muhammad Nur Salihin Yusoff; Ahmad Fairuz Omar; Nur Hartini Mohd Taib
Journal:  Sensors (Basel)       Date:  2019-05-14       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.