Literature DB >> 33532281

Diffusion-weighted magnetic resonance imaging (MRI) without susceptibility artifacts: single-shot stimulated echo acquisition mode (STEAM) MRI with iterative reconstruction and spatial regularization.

Dirk Voit1, Oleksandr Kalentev1, Jens Frahm1.   

Abstract

This work describes a new method for diffusion-weighted (DW) magnetic resonance imaging (MRI) without susceptibility artifacts. The technique combines a DW spin-echo module and a single-shot stimulated echo acquisition mode (STEAM) MRI readout with undersampled radial trajectories and covers a volume by a gapless series of cross-sectional slices. In a first step, optimal coil sensitivities for all slices are obtained from a series of non-DW acquisitions by nonlinear inverse reconstruction with regularization to the image and coil sensitivities of a directly neighboring slice. In a second step, these coil sensitivities are used to compute all series of non-DW and DW images by linear inverse reconstruction with spatial regularization to a neighboring image. Proof-of-principle applications to the brain (51 sections) and prostate (31 sections) of healthy subjects were realized for a protocol with two b-values and 6 gradient directions at 3 T. Including averaging the measuring times for studies of the brain at 1.0×1.0×3.0 mm3 resolution (b =1,000 s mm-2) and prostate at 1.4×1.4×3.0 mm3 resolution (b =600 s mm-2) were 2.5 min and 4.5 min, respectively. All reconstructions were accomplished online with use of a multi-GPU computer integrated into the MRI system. The resulting non-DW images, mean DW images averaged across directions and maps of the apparent diffusion coefficient confirm the absence of geometric distortions or false signal alterations and demonstrate diagnostic image quality. The novel method for DW STEAM MRI of a volume without susceptibility artifacts warrants extended clinical trials. 2021 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Keywords:  Diffusion-weighted magnetic resonance imaging (diffusion-weighted MRI); inverse reconstruction; radial undersampling; spatial regularization

Year:  2021        PMID: 33532281      PMCID: PMC7779911          DOI: 10.21037/qims-20-871

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  1 in total

1.  STEAM-DWI as a robust alternative to EPI-DWI: Evaluation in pediatric brain MRI.

Authors:  Daniel Gräfe; Anne Päts; Andreas Merkenschlager; Christian Roth; Franz Wolfgang Hirsch; Jens Frahm; Dirk Voit
Journal:  PLoS One       Date:  2022-05-18       Impact factor: 3.752

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.