Literature DB >> 33532259

Ex vivo vibro-acoustography characterization of osteoporosis in an experimental mice model.

Paulo Moraes Agnollitto1,2, Guilherme de Araújo Braz3, Adriano Levi Spirlandeli1, Francisco José Albuquerque de Paula1, Antonio Adilton Oliveira Carneiro3, Marcello Henrique Nogueira-Barbosa1,2.   

Abstract

BACKGROUND: Osteoporosis is a highly prevalent multifactorial osteometabolic disease, classically diagnosed, in vivo, by dual energy X-ray absorptiometry (DXA). This study evaluated osteoporosis, ex vivo, using vibro-acoustography (VA), an elastographic technique based on ultrasound radiation force.
METHODS: Three groups of mice femurs were used: (I) control group (CG), (II) osteoporosis group (OG) and (III) treated osteoporosis group (TOG), in which the animals received pamidronate, an antiresorptive drug. Evaluation was performed in an acoustic tank, using two high frequency focused beams produced by a confocal ultrasonic transducer. A hydrophone registered the low frequency acoustic response (AR) of bone samples. We used micro-computed tomography (microCT) as the reference standard and evaluated the correlation between VA and microCT parameters.
RESULTS: The spectral analyses of the ARs with estimated area under the curve (AUC) values (mean; st. dev.) were, respectively, 1.29e-07 and 9.32e-08 for the CG, 3.25e-08 and 2.16e-08 for the OG, and 1.50e-07 and 8.37e-08 for the TOG. VA differentiated the experimental groups (P<0.01) and the results were reproducible [interclass correlation coefficient (ICC): 0.43 (95% CI: 0.15-0.71)]. There was also a statistically significant association between VA and microCT connectivity (Conn.) (r=0.80; P<0.01) and connectivity density (Conn. D) (r=0.76; P<0.01).
CONCLUSIONS: These results encourage further studies aimed at evaluating the potential use of VA for the diagnosis of osteoporosis as a relatively low-cost and radiation-free alternative to DXA. 2021 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Entities:  

Keywords:  Vibro-acoustography (VA); mice; micro-computed tomography (microCT); osteoporosis; ultrasound

Year:  2021        PMID: 33532259      PMCID: PMC7779931          DOI: 10.21037/qims-20-610

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  63 in total

1.  Application of nonlinear phenomena induced by focused ultrasound to bone imaging.

Authors:  Samuel Callé; Jean-Pierre Remenieras; Olivier Bou Matar; Marielle Defontaine; Frederic Patat
Journal:  Ultrasound Med Biol       Date:  2003-03       Impact factor: 2.998

Review 2.  Comparison of the efficacy of sonography, magnetic resonance imaging and conventional radiography for the detection of bone erosions in rheumatoid arthritis patients: a systematic review and meta-analysis.

Authors:  Athan Baillet; Cécile Gaujoux-Viala; Gaël Mouterde; Thao Pham; Jacques Tebib; Alain Saraux; Bruno Fautrel; Alain Cantagrel; Xavier Le Loët; Philippe Gaudin
Journal:  Rheumatology (Oxford)       Date:  2011-01-28       Impact factor: 7.580

Review 3.  Ultrasound Elastography and MR Elastography for Assessing Liver Fibrosis: Part 1, Principles and Techniques.

Authors:  An Tang; Guy Cloutier; Nikolaus M Szeverenyi; Claude B Sirlin
Journal:  AJR Am J Roentgenol       Date:  2015-04-23       Impact factor: 3.959

4.  Difference-frequency generation in vibro-acoustography.

Authors:  Glauber T Silva; Farid G Mitri
Journal:  Phys Med Biol       Date:  2011-08-22       Impact factor: 3.609

Review 5.  Osteoporosis: screening, prevention, and management.

Authors:  Anna L Golob; Mary B Laya
Journal:  Med Clin North Am       Date:  2015-05       Impact factor: 5.456

6.  Metabolic bone disease of liver cirrhosis: is it parallel to the clinical severity of cirrhosis?

Authors:  C C Chen; S S Wang; F S Jeng; S D Lee
Journal:  J Gastroenterol Hepatol       Date:  1996-05       Impact factor: 4.029

7.  Axial transmission method for long bone fracture evaluation by ultrasonic guided waves: simulation, phantom and in vitro experiments.

Authors:  Kailiang Xu; Dean Ta; Runxin He; Yi-Xian Qin; Weiqi Wang
Journal:  Ultrasound Med Biol       Date:  2014-01-13       Impact factor: 2.998

8.  Sparse SVD Method for High-Resolution Extraction of the Dispersion Curves of Ultrasonic Guided Waves.

Authors:  Kailiang Xu; Jean-Gabriel Minonzio; Dean Ta; Bo Hu; Weiqi Wang; Pascal Laugier
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-07-18       Impact factor: 2.725

Review 9.  The laboratory rat as an animal model for osteoporosis research.

Authors:  Pavlos P Lelovas; Theodoros T Xanthos; Sofia E Thoma; George P Lyritis; Ismene A Dontas
Journal:  Comp Med       Date:  2008-10       Impact factor: 0.982

10.  UK clinical guideline for the prevention and treatment of osteoporosis.

Authors:  J Compston; A Cooper; C Cooper; N Gittoes; C Gregson; N Harvey; S Hope; J A Kanis; E V McCloskey; K E S Poole; D M Reid; P Selby; F Thompson; A Thurston; N Vine
Journal:  Arch Osteoporos       Date:  2017-04-19       Impact factor: 2.617

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.