Bispectral index monitoring of the clinical effects of propofol closed-loop target-controlled infusion: Systematic review and meta-analysis of randomized controlled trials.

Danyang Wang1, Zichen Song, Chunlu Zhang, Peng Chen.   

Abstract

BACKGROUND: To investigate whether closed-loop systems under bispectral index anesthesia depth monitoring can reduce the intraoperative propofol dosage.
METHODS: All randomized controlled trials (RCTs) on reducing propofol dosage under closed-loop systems were collected, and the literature was screened out, the abstracts and full texts were carefully read, and the references were tracked, data extraction and quality evaluation were conducted on the included research, and the RevMan5.3 software was used for meta-analysis. The main results were propofol and the incidence of adverse reactions such as hypertensive hypotension and postoperative cognitive dysfunction. A total of 879 cases were included in 8 articles, including 450 occurrences in the closed-loop system group and 429 cases in the open-loop system group.
RESULTS: Compared with manual control, closed-loop systems under bispectral index anesthesia depth monitoring reduced the dose of propofol (MD: -0.62, 95% CI: -1.08--0.16, P = .008), with heterogeneity (I2 = 80%). Closed-loop systems significantly reduced the incidence of abnormal blood pressure (MD: -0.02, 95%CI: -0.05-0.01, P = .15, I2 = 74%) and postoperative cognitive dysfunction (MD: -0.08, 95% CI: -0.14 -0.01, P = .02, I2 = 94%).
CONCLUSION: Bispectral index monitoring of propofol closed-loop target-controlled infusion system can reduce the amount of propofol, reduce the incidence of adverse reactions such as hypertensive or hypotension and postoperative cognitive dysfunction.
Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33530193      PMCID: PMC7850716          DOI: 10.1097/MD.0000000000023930

Source DB:  PubMed          Journal:  Medicine (Baltimore)        ISSN: 0025-7974            Impact factor:   1.817


Introduction

The bispectral index mainly reflects the excited or inhibited state of the cerebral cortex and the information of sedation and hypnosis, which is not only closely related to healthy physiological sleep but also can well monitor the sedative components in the depth of anesthesia.[ The appropriate depth of anesthesia is beneficial to the perioperative period's safety and the reduction of postoperative complications.[ Target - controlled infusion (TCI) is divided into open - loop systems and closed-loop systems. Open-loop systems are that the anesthesiologist adjusts the infusion speed or target concentration of the drug according to his own clinical experience, to maintain a certain depth of anesthesia, likely to cause too deep or too shallow anesthesia.[ The closed-loop system connects BIS and other anesthesia depth detectors to the computer executing TCI into a system that automatically adjusts the target concentration and independently forms a closed feedback loop. Therefore, we believe that the intravenous anesthesia closed-loop controlled drug delivery system guided by the bispectral index will be widely used in anesthesia. Closed-loop propofol systems have been used in general anesthesia, sedative anesthesia, and combined anesthesia with other anesthesia methods. However, long-term heavy use of propofol can lead to propofol infusion syndrome, especially in children.[ The closed-loop system of propofol can avoid too deep anesthesia, reduce the use of propofol, and make the use of anesthesia personalized. Propofol closed-loop systems can maintain a stable depth of anesthesia, avoid too deep or too shallow anesthesia, and reduce the incidence of postoperative delirium and cognitive dysfunction. The disadvantages of closed-loop systems of propofol are due to the influence of various factors on the double frequency index of EEG and the delay of feedback. However, whether the total dose of propofol is related to the use of the closed-loop system is controversial. Nevertheless, so far, the use of propofol closed-loop systems has been controversial. Although a number of randomized clinical trials have been published comparing BIS - guided closed - loop and open - loop systems, there has been no meta-analysis to explore the advantages of propofol closed-loop anesthesia. To determine the applicability of the propofol closed-loop methods, a systematic review of the previously published randomized controlled trials was conducted.[

Methods

Search strategy

We first searched several databases and then devised a search strategy for specific sources in consultation with information experts. The search was conducted to identify articles published before 2020, preferably in the last 5 years, using electronic sources MEDLINE, CINAHL, the Cochrane library (systematic reviews and trials), and EMBASE. Keywords such as “bispectral index,” “closed-loop systems,” “propofol,” and their synonyms were used in different combinations, and duplicates were removed. The search criteria (in titles, abstracts, and/or all fields) were as follows: closed-loop system; closed-loop control; closed-loop anesthesia control; manual; automated; bispectral index; (7)propofol; Randomized Controlled Trial; 1 OR 2 OR 3 OR 4 OR 5 AND 6 AND 7 AND 8. Furthermore, to ensure that all relevant literature was collected, we manually searched the references of eligible articles. This study is a systematic review and meta-analysis and is a summary of previous literature. Therefore, ethical approval from the Ethics Committee is not required. Patient consent is not involved in this article. Published comparative study on closed-loop systems and open-loop systems of propofol under the guidance of BIS; The study of all by intravenous anesthesia; The included studies were randomized controlled trials and included at least 2 groups, namely the BIS-guided propofol closed-loop system group (no limitation on equipment and pharmaceutical model, plasma TCI or effector compartment TCI) and the propofol open-loop system group (no restriction on infusion algorithm). Languages included in the research are limited to Chinese and English. The study of intravenous anesthesia combined with inhalation anesthesia; Unintubated study of general anesthesia; Reviews, abstracts, conference proceedings, letters to the editor, meta-analyses, case reports, and retrospective and preliminary studies.

Selection criteria

Data extraction and quality assessment

Two researchers searched the literature based on the inclusion and exclusion criteria above and then extracted data from all the included articles, including publication time, first author name, geographical area, subject age, number of cases, and results, tabulated and analyzed the extracted data.[ Researchers read the original literature and visited the clinical trial public management platform and clinical trial registry to obtain data. If we encounter documents outside of English and China, we will use Google and other translation software for literature and data translation, or contact the corresponding author of the article to understand the original data. In the case that the data could not be publicly stored, researchers contacted the corresponding author of the article to get the original data researchers needed. Cochrane review system was used to evaluate the quality of the included studies.[ Cochrane evaluation system consists of the actual contents of bias such as allocation concealment, random sequence generation, blind method of outcome evaluation, blind method of participants and personnel, selective report, incomplete result data, and so on, which can objectively and comprehensively evaluate various biases in the study.

Statistical analysis

Data as median and range are converted to mean and SD, following a published formula.[ We calculated MD and 95% CI to summarize the heterogeneity test of continuous data using either the Chi-Squared test or the Cochran-based I2 test.[ When significant heterogeneity (I2 > 50%) was observed, a random effect model was used. Otherwise, the fixed-effect model was used for meta-analysis. Propofol dosage, the incidence of hypertension or hypotension, and the impact of postoperative cognitive impairment were determined in each eligible study. The effect of closed-loop systems and open-loop systems on anesthesia of patients with different operation duration was analyzed in a subgroup. To evaluate the stability of the results, we conducted a sensitivity analysis by removing each one study at a time. For all the reviews, a P value of less than .05 was considered statistically significant.

Results

Study selection

The process of searching, screening, and study selection is summarized in Figure 1. Our researches found 1169 articles through database searching (Pubmed = 349, Medline = 131, Web of Science = 122, Embase = 127, Cochrane Library = 134, Ovid = 32, Springer = 44, CKNI = 155, WanFang Data = 75). What is more, 245 additional articles were identified through other sources. After removing duplicates (n = 654) and articles not satisfying the inclusion criteria (n = 577), 183 articles were assessed for eligibility. One hundred seventy five articles were removed because they were not RCT, and the data reported were incomplete. Finally, 8 studies were included in qualitative sysnthesis.[
Figure 1

The flow chart showing the process of study selection and the retrieved results.

The flow chart showing the process of study selection and the retrieved results.

Study characteristics

The characteristics of the selected studies are summarized in Table 1.[ In these 8 articles, 2 were multicenter studies.[ A total of 8 sections, including 879 patients, included 450 patients in the closed-loop system group and 429 patients in the manually controlled open-loop system group. The quality of these articles was assessed using the Cochrane manual evaluation criteria, as shown in Figure 2. All RCTs employed BIS as guidance for experiment groups. The majority of RCTs included adults (18–80 years), except for 1 RCT conducted by Louvet that included elective patients aged 4 to 14. Patients from 2 studies underwent short-time surgery, such as ear, nose and throat surgery, ophthalmic surgery, and dermatologic surgery.[ Whereas; patients from 2 studies underwent long-time surgery, such as liver transplantation surgery and open cardiac surgery.[
Table 1

The characteristics of the selected studies.

StudyPatient recruitmentCountrySample sizeAge (years)Study designSurgery
Cao 2017January 2014–December 2015China6040–60RCTliver transplantation surgery
Joosten 2019May 2017–February 2018.Belgium89>60RCTnoncardiac surgery
Louvet 2016March 2006–February 2007.France724–14RCTmiddle ear surgery
Mahajan 2017January 2014–November 2014India4018–65RCTopen cardiac surgery
Puri 2016January 2010–September 2012India24218–60RCTnonthoracic/nonvascular/non-neurosurgical surgery
Rüsch 2018February 2012–April 2013Germany23518–80RCTear, nose and throat surgery, Ophthalmic surgery, and dermatologic surgery
Yong 2017January 2016–August 2016China6065–75RCTGastrointestinal tumor resection surgery
Zhou 2018January 2014–November 2016China8165–75RCTcolon carcinoma radical surgery
Figure 2

Sensitivity and specificity of the included studies. represents a low risk of bias; stands for unclear risk of bias; represents a high risk of bias.

The characteristics of the selected studies. Sensitivity and specificity of the included studies. represents a low risk of bias; stands for unclear risk of bias; represents a high risk of bias.

Primary analysis

Our primary analyses aimed to compare the effect of closed-loop systems with open-loop systems. Our primary outcome was to evaluate the propofol dosage of automated control versus manual control (MD: −0.62, 95%CI: −1.08–−0.16, P = .008, Fig. 3), with heterogeneity (I2 = 80%). Compared with manual control, BIS-guided automated systems decreased the dosage of propofol. Three trials (2, 5, 7) reported the incidence of hypertension or hypotension as the outcome. Hypertension or hypotension is when a patients blood pressure during anesthesia is 20 percent higher or lower than when they enter the surgery room.[ The pooled MD for the incidence of hypertension or hypotension from 3 studies (closed-loop system group versus open-loop system group) was −0.02 (95%, CI: −0.05–0.01, P = .15, Fig. 4), with heterogeneity (I2 = 74%). A total of 4 literatures[ reported POCD-associated results. Using closed-loop systems during intravenous anesthesia significantly reduced postoperative cognitive dysfunction (MD: −0.08, 95%, CI: −0.14 –0.01, P = .02, Fig. 5), with significant heterogeneity among the studies (I2 = 94%). The results showed that the difference in the 3 outcomes mentioned above between the closed-loop system group and the open-loop system group was statistically significant.
Figure 3

Forest plot of meta-analysis of the effects of closed-cloop systems versus open-loop systems on the dosage of propofol.

Figure 4

Forest plot of meta-analysis of the effects of closed-cloop systems versus open-loop systems on the incidence of hypertension or hypotension.

Figure 5

Forest plot of meta-analysis of the effects of closed-cloop systems versus open-loop systems on the incidence of POCD.

Forest plot of meta-analysis of the effects of closed-cloop systems versus open-loop systems on the dosage of propofol. Forest plot of meta-analysis of the effects of closed-cloop systems versus open-loop systems on the incidence of hypertension or hypotension. Forest plot of meta-analysis of the effects of closed-cloop systems versus open-loop systems on the incidence of POCD.

Subgroup analysis

Subgroup analyses were performed based on the surgery operation time (Fig. 6). For patients undergoing short time surgery less than 2 hours, MD for the dosage of propofol from 2 studies was −0.31 (95%, CI: −1.05–−0.44, P = .42), with no heterogeneity (I2 = 44%). For 2 to 4 hour surgical patients, MD was −0.99 (95%, CI: −1.89–−0.09, P = .03), with no heterogeneity (I2 = 88%). While, for patients undergoing liver transplantation and open cardiac surgery, MD was −0.18 (95%, CI: −0.78–0.43, P = .57), with no heterogeneity (I2 = 0%). The subgroup analysis showed that the difference of propofol dosage in short and medium time surgery such as non-cardiac surgery between the closed-loop system group and the open-loop system group was statistically significant.
Figure 6

Forest plot of meta-analysis of the effects of closed-cloop systems versus open-loop systems on the subgroup analyses based on the surgery operation time.

Forest plot of meta-analysis of the effects of closed-cloop systems versus open-loop systems on the subgroup analyses based on the surgery operation time.

Publication bias and sensitivity analysis

We assessed publication bias; no significant publication bias was found for propofol dosage (P = .01, Fig. 7). Sensitivity analysis and publication bias through removing one study per article, we found that the merged results were not stable (Table 2).
Figure 7

Funnel plot for assessing publication bias.

Table 2

Sensitivity analysis and publication bias.

PI2MD95%, CI
Original.00880%−0.62[−1.08, −0.16]
Removed 1.0183%−0.67[−1.19, −0.16]
Removed 2.0282%−0.63[−1.16, −0.10]
Removed 3.0282%−0.59[−1.07, −0.11]
Removed 4.00783%−0.70[−1.20, −0.20]
Removed 5.00982%−0.76[−1.33, −0.19]
Removed 6.0178%−0.75[−1.34, −0.15]
Removed 7.0372%−0.44[−0.84, −0.04]
Removed 8.0371%−0.44[−0.84, −0.03]
Funnel plot for assessing publication bias. Sensitivity analysis and publication bias.

Discussion

The bispectral index is a digital scale based on the electrical activity of the brain, which decreases with the increase of the depth of anesthesia.[ The bottom of anesthesia is an essential objective index to evaluate the effect of anesthesia, important feedback information in the closed-loop system, and a key to the establishment of closed-loop systems.BIS values are usually maintained between 40 and 60 during anesthesia maintenance.[ There is evidence that monitoring and maintaining BIS values of 40 to 60 in TIVA can reduce the incidence of intraoperative awareness by more than 80%.[ Hemodynamic stability is also an essential goal of anesthesia patient management. Clinical studies have found that intraoperative anesthesia depth monitoring can maintain hemodynamic stability and reduce the incidence of perioperative hypertension or hypotension.[ This meta-analysis proved that closed-loop systems could control the depth of anesthesia better than open-loop systems, reduce the dosage of drugs, and reduce the incidence of perioperative adverse reactions. This conclusion is consistent with previous clinical studies. This may be because maintaining a reasonable depth of anesthesia can reduce the impact of intraoperative consciousness, reduce the violent fluctuation of circulation, increase the dosage of anesthetic drugs, accelerate the patient's recovery time, improve the quality of anesthesia, and reduce the occurrence of anesthesia complications. Abnormal blood pressure includes hypertension, hypotension and other human factors. Because some pieces of literature only listed the number of patients with abnormal blood pressure, this meta-analyzed hypertension and hypotension together. In this study, meta-analysis proved that the closed-loop group could reduce the dosage of propofol and reduce the incidence of intraoperative hypertension, hypotension, and postoperative cognitive dysfunction. This is because under the guidance of BIS propofol closed-loop systems by the computer automatically extract the BIS value analysis and calculation, with high sensitivity, can adjust in time for the small fluctuations in the BIS value target concentration and infusion rate, reduce the lag of “BIS changing clinically→ target concentration regulation →clinical effects” in open-loop systems.[ However, some studies have found that BIS value is specified in the judgment of consciousness, but the sensitivity is not enough.[ There is a lag in the monitoring of knowledge, which cannot clearly distinguish the existence of consciousness from the disappearance of consciousness. At present, the anesthesia depth detector needs further development and improvement. This real-time intelligent intravenous closed-loop controlled drug delivery system can not only integrate the indicators of anesthesia depth monitoring and automatically adjust the drug delivery rate, but also adjust and intervene with vital signs, such as blood pressure and heart rate, in the future, to maintain the stability of satisfactory anesthesia depth and circulation function and achieve robot anesthesia.[ This study has some shortcomings. First of all, BIS values can be influenced by several factors, such as intraoperative opioid and muscle relaxant levels. Due to the limitation of conditions, it is impossible to control the use of the same analgesic and muscle relaxant during the operation, so there may be some errors in this study. Also, the sample size collected in this study was small, so some large sample size randomized controlled trials need to be further carried out to explore the clinical efficacy of BIS in monitoring closed-loop systems of propofol. Finally, this study did not classify the population according to age or surgical method. Future studies should refine the population classification and add subgroup analysis, to make the results more accurate and targeted. In this study, the dosage of propofol in the closed-loop group was less than that in the open-loop group. This could not only control the anesthetic depth but also avoid the waste of anesthetic drugs and reduce the adverse reactions caused by overdose and accumulation of anesthetic drugs. However, the relevant factors cannot be extracted and analyzed in this study. A large number of reasonably designed and rigorous studies are needed to verify the results of this study further. Randomized controlled trials are required to reflect the features of closed-loop systems in the future.[

Conclusion

Our results showed that closed-loop systems can control the depth of anesthesia better than open-loop systems during the maintenance period of intravenous anesthesia, and can reduce the dosage of drugs and the incidence of intraoperative and postoperative adverse reactions. However, more studies with large sample sizes were still needed to support our results.

Author contributions

Danyang Wang and Zichen Song contributed to the study concept and design, analysis and interpretation of data, statistical analysis, and drafting of the manuscript. Chunlu Zhang contributed to the acquisition of the data. Peng Chen contributed to the study concept and design and study supervision. All authors have read and approved the manuscript, and ensure that this is the case. Data curation: Zichen Song, Chunlu Zhang. Funding acquisition: Peng Chen. Writing – original draft: Danyang Wang.
  31 in total

1.  Monitoring Depth of Hypnosis: Mid-Latency Auditory Evoked Potentials Derived aepEX in Children Receiving Desflurane-Remifentanil Anesthesia.

Authors:  Yuen M Cheung; Gail P Scoones; Robert Jan Stolker; Frank Weber
Journal:  Anesth Analg       Date:  2020-01       Impact factor: 5.108

2.  Effects of closed-loop intravenous anesthesia guided by Bispectral Index in adult patients on emergence delirium: a randomized controlled study.

Authors:  Antonella Cotoia; Lucia Mirabella; Renata Beck; Pompeo Matrella; Valentina Assenzo; Thierry Chazot; Gilda Cinnella; Ngai Liu; Michele Dambrosio
Journal:  Minerva Anestesiol       Date:  2017-12-13       Impact factor: 3.051

3.  The relationship between pre-operative hypertension and intra-operative haemodynamic changes known to be associated with postoperative morbidity.

Authors:  M Crowther; K van der Spuy; F Roodt; M B Nejthardt; J G Davids; J Roos; E Cloete; T Pretorius; G L Davies; J G van der Walt; C van der Westhuizen; M Flint; J L C Swanevelder; B M Biccard
Journal:  Anaesthesia       Date:  2018-03-12       Impact factor: 6.955

4.  The Effect of Dexmedetomidine on Propofol Requirements During Anesthesia Administered by Bispectral Index-Guided Closed-Loop Anesthesia Delivery System: A Randomized Controlled Study.

Authors:  Amitabh Dutta; Nitin Sethi; Jayashree Sood; Bhuwan C Panday; Manish Gupta; Prabhat Choudhary; Goverdhan D Puri
Journal:  Anesth Analg       Date:  2019-07       Impact factor: 5.108

5.  A Procedural Electroencephalogram Simulator for Evaluation of Anesthesia Monitors.

Authors:  Christian Leth Petersen; Matthias Görges; Roslyn Massey; Guy Albert Dumont; J Mark Ansermino
Journal:  Anesth Analg       Date:  2016-11       Impact factor: 5.108

6.  Bispectral index under propofol anesthesia in children: a comparative randomized study between TIVA and TCI.

Authors:  Nicolas Louvet; Agnès Rigouzzo; Nada Sabourdin; Isabelle Constant
Journal:  Paediatr Anaesth       Date:  2016-09       Impact factor: 2.556

7.  Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range.

Authors:  Xiang Wan; Wenqian Wang; Jiming Liu; Tiejun Tong
Journal:  BMC Med Res Methodol       Date:  2014-12-19       Impact factor: 4.615

8.  Effect of bispectral index-guided anesthesia on consumption of anesthetics and early postoperative cognitive dysfunction after liver transplantation: An observational study.

Authors:  Ying-Hao Cao; Ping Chi; Yan-Xing Zhao; Xi-Chen Dong
Journal:  Medicine (Baltimore)       Date:  2017-09       Impact factor: 1.889

9.  Bispectral index to guide induction of anesthesia: a randomized controlled study.

Authors:  Dirk Rüsch; Christian Arndt; Leopold Eberhart; Scarlett Tappert; Dennis Nageldick; Hinnerk Wulf
Journal:  BMC Anesthesiol       Date:  2018-06-15       Impact factor: 2.217

10.  Comparison of bispectral index and end-tidal anaesthetic concentration monitoring on recovery profile of desflurane in patients undergoing lumbar spine surgery.

Authors:  R Sudhakaran; Jeetinder K Makkar; Divya Jain; Jyotsna Wig; R Chabra
Journal:  Indian J Anaesth       Date:  2018-07
View more
  2 in total

1.  The Median Effective Dose and Bispectral Index of Remimazolam Tosilate for Anesthesia Induction in Elderly Patients: An Up-and-Down Sequential Allocation Trial.

Authors:  Miao Liu; Yuan Sun; Lingxue Zhou; Kunpeng Feng; Tianlong Wang; Xuexin Feng
Journal:  Clin Interv Aging       Date:  2022-05-20       Impact factor: 3.829

2.  The effects of target-controlled infusion of lidocaine undergoing vocal cord polypectomy: A randomized controlled trial (CONSORT compliant).

Authors:  LongYuan Zhou; RuiLan Wu; Chang Cai; Yong Qi; XingHua Bi; Qi Hang
Journal:  Medicine (Baltimore)       Date:  2022-02-11       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.