BACKGROUND: Previous reports of extracellular matrix (ECM) patch use after carotid endarterectomy (CEA) have noted an approximately 10% rate of pseudoaneurysm (PSA) formation. PSA-related rupture of ECM patches has also been described after femoral artery repair. In these studies, different thicknesses (4-ply versus 6-ply) and no standard length of soaking the patch in saline before implantation were used. Herein, we describe our experience with ECM CorMatrix patches in 291 CEAs with 6-ply patches.
METHODS: The records of 275 consecutive patients undergoing 291 CEAs with CorMatrix 6-ply patches beginning in November of 2011 and extending until 2015 were reviewed. Only 6-ply patches and a 1 min hydration time in saline were used in all patients. No shunts were used.
RESULTS: There were three deaths within the first 30 d secondary to subsequent cardiac surgical procedures. Nine patients experienced a perioperative stroke (3.1%), only one of which occurred secondary to an occluded internal carotid artery. One patient had a transient ischemic attack with a patent endarterectomy site. In follow-up, 11 patients (4.5%) developed severe recurrent stenoses requiring reintervention. Only one patient (0.34%) developed a PSA at 2 years possibly secondary to chronic infection. The median follow-up was 72 mo.
CONCLUSIONS: Our experience with 6-ply CorMatrix ECM patches and a brief period of soaking demonstrated that these patches performed well in patients requiring a CEA. Only one PSA was noted.
Copyright © 2021 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CEA; Extracellular matrix patches

Year:  2021        PMID: 33530005     DOI: 10.1016/j.jss.2021.01.001

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  3 in total

1.  Surgical Reconstruction of a Left Ventricular Aneurysm Using an Extracellular Matrix Patch.

Authors:  Igor Zivkovic; Vladimir Mihajlovic; Djordje Zdravkovic; Djordje Krstic; Srasa Krasic; Jelena Lesanovic; Miodrag Peric; Petar Milacic
Journal:  Braz J Cardiovasc Surg       Date:  2022-05-02

Review 2.  Selection criteria for patch angioplasty material in carotid endarterectomy.

Authors:  Nur Setiawan Suroto; Fedik Abdul Rantam; Asra Al Fauzi; Prihartini Widiyanti; Agus Turchan; Vega Pangaribuan
Journal:  Surg Neurol Int       Date:  2022-08-19

3.  Pathological Changes of Adult Mitral Valves after Failed CorMatrix ECM Repair.

Authors:  Baidarbhi Chakraborty; He Wang
Journal:  J Clin Transl Pathol       Date:  2021-08-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.