Literature DB >> 33529534

Highly Stable Covalent Organic Framework Nanosheets as a New Generation of Electrochemiluminescence Emitters for Ultrasensitive MicroRNA Detection.

Jin-Ling Zhang1, Yang Yang1, Wen-Bin Liang1, Li-Ying Yao1, Ruo Yuan1, Dong-Rong Xiao1.   

Abstract

A pyrene-based sp2 carbon-conjugated covalent organic framework (COF) nanosheet (Py-sp2c-CON) with strong and stable electrochemiluminescence (ECL) emission was constructed by C═C polycondensation of tetrakis(4-formylphenyl)pyrene (TFPPy) and 2,2'-(1,4-phenylene)diacetonitrile, which was employed as a highly efficient ECL emitter to fabricate an ECL biosensor for the first time. The Py-sp2c-CON exhibited higher ECL intensity and efficiency than those of TFPPy, bulk Py-sp2c-COF, and imine-linked pyrene COF, not only because the pyrene luminophores and aggregation-induced emissive luminogens (cyano-substituted phenylenevinylene) were topologically linked into Py-sp2c-CON, which greatly increased the immobilization amount of luminophores and decreased the aggregation-caused quenching effect and nonradiative transition but also because the porous ultrathin structure of Py-sp2c-CON effectively shortened transport distances of an electron, ion, and co-reactant (S2O82-), which made more ECL luminophores be activated and thus efficiently increased the utilization ratio of luminophores. More interestingly, when Bu4NPF6 was introduced into the Py-sp2c-CON/S2O82- system as a co-reaction accelerator, the ECL signal of Py-sp2c-CON was further amplified. As expected, the average ECL intensity of the Py-sp2c-CON/S2O82-/Bu4NPF6 system was about 2.03, 5.76, 24.31, and 190.33-fold higher than those of Py-sp2c-CON/S2O82-, Py-sp2c-COF/S2O82-, TFPPy/S2O82,- and imine-linked pyrene COF/S2O82- systems. Considering these advantages, the Py-sp2c-CON/S2O82-/Bu4NPF6 system was employed to prepare an ECL biosensor for microRNA-21 detection, which exhibited a broad linear response (100 aM to 1 nM) and a low detection limit (46 aM). Overall, this work demonstrated that sp2 carbon CONs can be directly used as a high-performance ECL emitter, thus expanding the application scope of COFs and opening a new horizon to develop new types of ECL emitters.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33529534     DOI: 10.1021/acs.analchem.0c04931

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  A general design approach toward covalent organic frameworks for highly efficient electrochemiluminescence.

Authors:  Ya-Jie Li; Wei-Rong Cui; Qiao-Qiao Jiang; Qiong Wu; Ru-Ping Liang; Qiu-Xia Luo; Jian-Ding Qiu
Journal:  Nat Commun       Date:  2021-08-05       Impact factor: 14.919

Review 2.  Progress and Prospects of Electrochemiluminescence Biosensors Based on Porous Nanomaterials.

Authors:  Chenchen Li; Jinghui Yang; Rui Xu; Huan Wang; Yong Zhang; Qin Wei
Journal:  Biosensors (Basel)       Date:  2022-07-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.