Evaluation of processes, outcomes, and use of midline peripheral catheters for the purpose of blood collection.

Daleen Penoyer1, Melody Bennett1, Patricia I Geddie2, Alyssa Nugent3, Tara Volkerson3.   

Abstract

HIGHLIGHTS: Results added knowledge on use of midline catheters (MCs) for blood sampling. Using MCs for blood withdrawal resulted in low rates of hemolysis (0.69%). Dwell time was longer in those who had blood drawn from their MC. Nurse practices for blood sampling from MCs varied and learned from other nurses.
BACKGROUND: Blood withdrawal from midline catheters (MCs) is done clinically, but no studies were found evaluating outcomes from this procedure, nor were clinical guidelines found. Drawing blood samples from short peripheral catheters is associated with higher hemolysis rates.
METHODS: A prospective, observational, mixed methods study was used to evaluate outcomes from using MCs for blood withdrawal. Focus group sessions were held to evaluate nurses' practices for this procedure.
RESULTS: Data were collected over 3 months on 397 MCs in 378 patients. Hemolysis rates when the MC was used for blood withdrawal was 0.69% in 1021 tests. More than half had blood specimens drawn through the MC, and the time known for the successful withdrawal was on average 64 ± 85 hours. Mean dwell time for all MCs was 108.5 ± 98 hours, and when MCs were used for blood withdrawal, mean dwell time was 127.19 ± 109.13 hours and for MCs not used for blood withdrawal, 88.34 ± 79.86 hours (P < 0.001). In 338 patients who received therapy through their MC (n = 338), 87% completed intended therapy: 88% with blood withdrawal and 81% without blood withdrawal. Qualitative analysis from focus groups demonstrated wide variation in practice for blood sampling from MCs, and most learned techniques from their preceptors, other nurses, or patients.
CONCLUSIONS: Findings indicated that blood withdrawal from one specific type of MC had low rates of hemolysis, increased dwell time, and completion of therapy. More studies are needed to determine best practices for blood sampling through various types of MCs and outcomes.

Entities:  

Keywords:  Blood collection; Blood sampling; Dwell time; Hemolysis; Midline catheter

Mesh:

Year:  2021        PMID: 33529105     DOI: 10.12968/bjon.2021.30.2.S24

Source DB:  PubMed          Journal:  Br J Nurs        ISSN: 0966-0461


  1 in total

1.  Efficacy and Safety of Midline Catheters with Integrated Wire Accelerated Seldinger Technique.

Authors:  Mun Hee Jeon; Cheol Seung Kim; Kyu Dam Han; Mi Jin Kim
Journal:  Vasc Specialist Int       Date:  2022-03-21
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.