Literature DB >> 33528712

Fluoroless catheter ablation of accessory pathways in adult and pediatric patients: a single centre experience.

Mehmet Yazici1, Nikola Lakič1, Tine Prolič Kalinšek1, David Žižek2, Katja Ažman Juvan1, Mirko Topalović3, Gordan Mijovski4, Matevž Jan5.   

Abstract

Catheter radio-frequency ablation (RFA) and cryo-ablation (CRA) procedures are an effective and safe treatment options for adult and pediatric patients with accessory pathway (AP) mediated tachycardias. Non-fluoroscopic techniques during catheter ablation (CA) procedures reduce potentially harmful effects of radiation. Our aim was to investigate the efficacy and safety of completely fluoroless RFA and CRA procedures in pediatric and adult patients with APs. Consecutive patients with AP-related tachycardia and high risk asymptomatic ventricular pre-excitation were assessed in retrospective analysis. Three-dimensional (3D) electro-anatomical mapping (EAM) and intra-cardiac echocardiography (ICE) were used as principal imaging modalities. Fluoroscopy was not used during any stage of the procedures. Among 116 included patients (22.76 ± 16.1 years, 68 patients < 19 years), 60 had left-sided APs, 16 right-sided APs and 40 septal APs. Altogether, 96 had RFA and 20 CRA procedures. The acute success rates (ASR) of RFA and CRA were 97.9% and 95%, respectively (p = 0.43), with recurrence rates (RR) of 8.33% and 40%, respectively (p < 0.0001). The outcome difference was principally driven by lower RR with RFA in septal APs (9.1% vs. 38.9%, p = 0.025). Pediatric patients with APs (12.21 ± 3.76 years) had similar procedural parameters and outcomes compared to adult patients. There were no procedure-related complications. In adult and pediatric patients with AP-related tachycardias, both CRA and RFA can be effectively and safely performed without the use of fluoroscopy. In addition, RFA resulted in better outcomes compared to CRA.

Entities:  

Keywords:  Accessory pathways; Catheter ablation; Electro-anatomic mapping system; Fluoroless; Intra-cardiac echocardiography

Year:  2021        PMID: 33528712     DOI: 10.1007/s10554-021-02168-5

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  1 in total

1.  Catheter ablation in ASymptomatic PEDiatric patients with ventricular preexcitation: results from the multicenter "CASPED" study.

Authors:  Marta Telishevska; J Hebe; T Paul; J H Nürnberg; U Krause; R Gebauer; M Gass; C Balmer; F Berger; S Molatta; M Emmel; W Lawrenz; T Kriebel; G Hessling
Journal:  Clin Res Cardiol       Date:  2018-12-05       Impact factor: 5.460

  1 in total
  1 in total

1.  The First Evaluation of Remote Magnetic Navigation-Guided Pediatric Ventricular Arrhythmia Ablation.

Authors:  Anna M E Noten; Nawin L Ramdat Misier; Janneke A E Kammeraad; Sip Wijchers; Ingrid M Van Beynum; Michiel Dalinghaus; Thomas B Krasemann; Sing-Chien Yap; Natasja M S de Groot; Tamas Szili-Torok
Journal:  Pediatr Cardiol       Date:  2022-04-29       Impact factor: 1.838

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.