Literature DB >> 33525000

Using a Portable Near-infrared Spectroscopy Device to Estimate The Second Ventilatory Threshold.

Víctor Rodrigo-Carranza1, Fernando González-Mohíno2,3, Anthony P Turner3, Sergio Rodriguez-Barbero1, José María González-Ravé1.   

Abstract

A breakpoint in a portable near-infrared spectroscopy (NIRS) derived deoxygenated haemoglobin (deoxy[Hb]) signal during an incremental VO2max running test has been associated with the second ventilatory threshold (VT2) in healthy participants. Thus, the aim was to examine the association between this breakpoint (NIRS) and VT2 in well-trained runners. Gas exchange and NIRS data were collected during an incremental VO2max running test for 10 well-trained runners. The breakpoint calculated in oxygen saturation (StO2) and the VT2 were determined and compared in terms relative to %VO2max, absolute speed, VO2, and maximum heart rate (HRmax). There were no significant differences (p>0.05) between the breakpoint in StO2 and VT2 relative to %VO2max (87.00±6.14 and 88.28 ± 3.98 %), absolute speed (15.70±1.42 and 16.10±1.66 km·h-1), VO2 (53.71±15.17 and 54.66±15.57 ml·kg-1·min-1), and%HRmax (90.90±4.17 and 91.84±3.70%). There were large and significant correlations between instruments relative to%VO2max (r=0.68, p<0.05), absolute speed (r=0.86, p<0.001), VO2 (r=0.86, p<0.001), and %HRmax (r=0.69; p<0.05). A Bland and Altman analysis of agreement between instruments resulted in a mean difference of - 1.27±4.49%, -0.40±0.84 km·h-1,-0.90±3.07 ml·kg-1·min-1, and - 0.94±3.14 for %VO2max, absolute speed, VO2, and %HRmax, respectively. We conclude that a portable NIRS determination of the StO2 breakpoint is comparable with VT2 using gas exchange and therefore appropriate for use in determining exercise training above VT2 intensity. This is the first study to analyze the validity with the running mode using a NIRS portable device. Thieme. All rights reserved.

Entities:  

Year:  2021        PMID: 33525000     DOI: 10.1055/a-1343-2127

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  6 in total

Review 1.  Changes in Muscle Oxygen Saturation Measured Using Wireless Near-Infrared Spectroscopy in Resistance Training: A Systematic Review.

Authors:  Claudia Miranda-Fuentes; Luis Javier Chirosa-Ríos; Isabel María Guisado-Requena; Pedro Delgado-Floody; Daniel Jerez-Mayorga
Journal:  Int J Environ Res Public Health       Date:  2021-04-18       Impact factor: 3.390

2.  Comparing the Respiratory Compensation Point With Muscle Oxygen Saturation in Locomotor and Non-locomotor Muscles Using Wearable NIRS Spectroscopy During Whole-Body Exercise.

Authors:  Assaf Yogev; Jem Arnold; Dave Clarke; Jordan A Guenette; Ben C Sporer; Michael S Koehle
Journal:  Front Physiol       Date:  2022-03-24       Impact factor: 4.566

3.  Augmented Cooper test: Biomechanical contributions to endurance performance.

Authors:  Salil Apte; Simone Troxler; Cyril Besson; Vincent Gremeaux; Kamiar Aminian
Journal:  Front Sports Act Living       Date:  2022-09-14

Review 4.  Post-COVID-19 Syndrome and the Potential Benefits of Exercise.

Authors:  Amaya Jimeno-Almazán; Jesús G Pallarés; Ángel Buendía-Romero; Alejandro Martínez-Cava; Francisco Franco-López; Bernardino J Sánchez-Alcaraz Martínez; Enrique Bernal-Morel; Javier Courel-Ibáñez
Journal:  Int J Environ Res Public Health       Date:  2021-05-17       Impact factor: 3.390

5.  Determination of the Respiratory Compensation Point by Detecting Changes in Intercostal Muscles Oxygenation by Using Near-Infrared Spectroscopy.

Authors:  Felipe Contreras-Briceño; Maximiliano Espinosa-Ramirez; Vicente Keim-Bagnara; Matías Carreño-Román; Rafael Rodríguez-Villagra; Fernanda Villegas-Belmar; Ginés Viscor; Luigi Gabrielli; Marcelo E Andía; Oscar F Araneda; Daniel E Hurtado
Journal:  Life (Basel)       Date:  2022-03-17

6.  Muscle Oxygenation Unlocks the Secrets of Physiological Responses to Exercise: Time to Exploit it in the Training Monitoring.

Authors:  Stephane Perrey
Journal:  Front Sports Act Living       Date:  2022-03-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.