Electrocardiographic gating and monitoring in NMR imaging.

R E Wendt1, R Rokey, G W Vick, D L Johnston.   

Abstract

ECG gating and monitoring during NMR imaging may be achieved reliably by applying the principles in this tutorial. In order to use the ECG signal both for triggering and for patient monitoring it must have a prominent R-wave, while at the same time must have little artifact from gradient switches or the Lorentz voltage across the aorta, and not be significantly distorted by gradient switching artifacts. The twin goals of no image artifacts and minimal ECG artifacts may be achieved by the following means: (1) using ECG electrodes with minimal metal, (2) selecting electrodes and cables with no ferrous metals, (3) placing the limb electrodes close together, (4) placing the line between the limb electrodes and the leg electrode parallel to the magnetic flux lines and, if possible, parallel to the transverse component of the gradient flux lines, (5) keeping the area between the limb electrodes and the leg electrode small, (6) placing that area in the center of the imager and (7) twisting or braiding the cables. Following these principles allows artifact-free images and reliable ECG monitoring during ECG-gated NMR imaging examinations.

Entities:  

Mesh:

Year:  1988        PMID: 3352484     DOI: 10.1016/0730-725x(88)90528-0

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  7 in total

Review 1.  Review of new techniques in echocardiography and magnetic resonance imaging as applied to patients with congenital heart disease.

Authors:  D J Sahn; G W Vick
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

2.  Flow-compensated self-gating.

Authors:  Jessica Schulz; Matthias Korn; Michael Deimling; Wolfhard Semmler; Michael Bock
Journal:  MAGMA       Date:  2008-07-31       Impact factor: 2.310

3.  Prospective cardiac motion self-gating.

Authors:  Fei Han; Stanislas Rapacchi; Peng Hu
Journal:  Quant Imaging Med Surg       Date:  2017-04

Review 4.  Cardiac magnetic resonance imaging and its electrocardiographs (ECG): tips and tricks.

Authors:  Marcelo Souto Nacif; Anna Zavodni; Nadine Kawel; Eui-Young Choi; João A C Lima; David A Bluemke
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-28       Impact factor: 2.357

5.  Adaptive noise cancellation to suppress electrocardiography artifacts during real-time interventional MRI.

Authors:  Vincent Wu; Israel M Barbash; Kanishka Ratnayaka; Christina E Saikus; Merdim Sonmez; Ozgur Kocaturk; Robert J Lederman; Anthony Z Faranesh
Journal:  J Magn Reson Imaging       Date:  2011-05       Impact factor: 4.813

6.  Carbon tube electrodes for electrocardiography-gated cardiac multimodality imaging in mice.

Authors:  Philippe Choquet; Christian Goetz; Gaelle Aubertin; Fabrice Hubele; Sébastien Sannié; André Constantinesco
Journal:  J Am Assoc Lab Anim Sci       Date:  2011-01       Impact factor: 1.232

7.  Comparison of self-gated cine MRI retrospective cardiac synchronization algorithms.

Authors:  Grace M Nijm; Alan V Sahakian; Steven Swiryn; James C Carr; John J Sheehan; Andrew C Larson
Journal:  J Magn Reson Imaging       Date:  2008-09       Impact factor: 4.813

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.