Literature DB >> 33522672

Management of peri-device leak following left atrial appendage closure: A systematic review.

Jose R Sleiman1, Antonio J Lewis1, Eduardo J Perez1, Alexandra M Sanchez1, Jose L Baez-Escudero1, Jose L Navia1, Craig R Asher1, Robert J Cubeddu1.   

Abstract

OBJECTIVE: This study aimed to examine the cumulative experience of peri-device leak (PDL) closure following left atrial appendage (LAA) closure.
BACKGROUND: The management of PDL following LAA closure remains controversial. While PDL closure has been proposed, procedural features and clinical outcomes have not been well established.
METHODS: A systematic review of all published cases of PDL closure with available anatomical, procedural, and clinical outcomes was performed.
RESULTS: We identified 18 indexed publications and 110 cases between April 2013 and March 2020. 71 patients (mean age 72 ± 8 yrs), met study criteria and were included. PDL closure was most common in males, bilobar LAA morphology, and after Watchman procedures. The mean PDL size was 7.6 ± 5.8 mm (range 2-26 mm). Leaks were classified according to size: small (<5 mm; 45%), moderate (≥5-9 mm; 25%), and large (≥10 mm; 30%). Endovascular coils and endovascular plugs were used to close both small and moderate sized leaks, and second LAA closure devices were exclusively used for large PDLs. Successful PDL closure occurred in 90%, and was similar between PDL sizes and types of occluder used. Procedural complication rates were uncommon (2.8%). No strokes were reported following PDL closure at 6 months.
CONCLUSIONS: In patients with PDL for whom discontinuation of OAC may be considered unsafe, percutaneous closure using a tailored approach with either endovascular coils, plugs, or second occluder represents a safe, and feasible alternative associated with favorable clinical outcomes.
© 2021 Wiley Periodicals LLC.

Entities:  

Keywords:  incomplete closure; left atrial appendage closure; peri-device leak; systematic review; watchman

Mesh:

Year:  2021        PMID: 33522672     DOI: 10.1002/ccd.29495

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  A Novel Echocardiographic-Based Classification for the Prediction of Peri-Device Leakage following Left Atrial Appendage Occluder Implantation.

Authors:  Ali Hamadanchi; Shun Ijuin; Franz Haertel; Tarek Bekfani; Julian Westphal; Marcus Franz; Sven Moebius-Winkler; P Christian Schulze
Journal:  J Clin Med       Date:  2022-02-18       Impact factor: 4.241

2.  Percutaneous Coiling for Late-Acquired Peri-Device Leak Following Left Atrial Appendage Occlusion.

Authors:  Nicolas Amabile; Alaa Masri; Khalil Mahmoudi; Christelle Diakov; Costantino Del Giudice
Journal:  JACC Case Rep       Date:  2022-08-03
  2 in total