Literature DB >> 33522302

Comparison of posterior capsule opacification between Clareon CNA0T0 and Tecnis ZCB00 intraocular lenses.

Cristina Almenara1,2,3, Francisco de Asís Bartol-Puyal1,2,3, Diana Soriano1,2,3, Miriam Idoipe1,2,3, María Chacón1,2, Silvia Méndez-Martínez1,2,3, Galadriel Giménez1,2,3, Vicente Polo1,2,3,4.   

Abstract

INTRODUCTION: The purpose is to compare posterior capsule opacification (PCO) and its impact on vision between Clareon CNA0T0 (Alcon) and Tecnis ZCB00 intraocular lenses (IOLs) (Johnson&Johnson) 1, 6, and 12 months after implantation.
METHODS: A prospective observational study was performed at the Nuestra Señora de Gracia Hospital (Zaragoza, Spain). Fifty eyes (50 patients) with Tecnis IOL (group 1) and 60 eyes (60 patients) with Clareon IOL (group 2) were enrolled. One, 6, and 12 months after age-related cataract surgery by five different surgeons, the following tests were performed: mesopic corrected distance visual acuity (CDVA), CSV1000-E test, KR-1W wavefront analyzer, OQAS II, Catquest-9SF questionnaire and mydriatic slit-lamp pictures. PCO intensity was quantified and the area of opacification was measured using ImageJ (NIH).
RESULTS: Mean age was 71.20 ± 6.79 years in group 1, and 71.73 ± 8.17 years in group 2 (p = 0.72); mean axial length was 23.46 ± 1.14 and 23.53 ± 0.91 mm, respectively (p = 0.72); mean IOL power was 21.69 ± 2.26 D and 21.28 ± 2.44 D, respectively (p = 0.37). One month after surgery there were differences in intensity of PCO (0.73 ± 0.60 and 1.05 ± 0.71, respectively, p = 0.02). Six months after surgery statistical differences were found in VA with 20% CS in mydriatic conditions (0.26 ± 0.21 logMAR (20/36) and 0.18 ± 0.17 logMAR (20/30), respectively, p = 0.04). Twelve months after surgery, no differences were detected between groups. As for the evolution of PCO within the Clareon group, high order aberrations (p < 0.05) and the Strehl ratio (p = 0.02) decreased.
CONCLUSION: There are no differences in slit-lamp pictures or visual function between both IOLs during the first 12 months after implantation.

Entities:  

Keywords:  Clareon CNA0T0; Tecnis ZCB00; posterior capsule opacification

Mesh:

Year:  2021        PMID: 33522302     DOI: 10.1177/1120672121991718

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  1 in total

1.  Predictive accuracy of an intraoperative aberrometry device for a new monofocal intraocular lens.

Authors:  Lindsay S Spekreijse; Noel J C Bauer; Frank J H M van den Biggelaar; Rob W P Simons; Claudette A Veldhuizen; Tos T J M Berendschot; Rudy M M A Nuijts
Journal:  J Cataract Refract Surg       Date:  2021-08-19       Impact factor: 3.528

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.