Literature DB >> 33516376

A novel QCM immunosensor development based on gold nanoparticles functionalized sulfur-doped graphene quantum dot and h-ZnS-CdS NC for Interleukin-6 detection.

Necip Atar1, Mehmet Lütfi Yola2.   

Abstract

Interleukin 6 (IL-6) acts as both a proinflammatory and anti-inflammatory cytokine and is generally utilized as an important diagnostic biomarker for sepsis. In addition, the high levels of IL-6 measured in plasma have been associated with pathological inflammation. A novel quartz crystal microbalance (QCM) immunoassay method was presented for high sensitivity and selectivity detection of interleukin-6 (IL-6) based on gold nanoparticles functionalized sulfur-doped graphene quantum dot (AuNPs/S-GQD) and hollow ZnS-CdS nanocage (h-ZnS-CdS NC). Firstly, AuNPs/S-GQD nanocomposite was synthesized in the presence of tetrachloroauric acid and then conjugated onto anti-IL-6 antibodies by amino-gold affinity. The sandwich-type QCM immunoassay probe was prepared by immune-reaction between AuNPs/S-GQD/QCM immobilized with anti-IL-6 capture antibodies and h-ZnS-CdS NC including detection anti-IL-6 antibodies in the presence of target IL-6. The prepared QCM immunoassay probe was characterized by transmission electron microscopy (TEM), scanning electron microscope (SEM), x-ray diffraction (XRD) method, x-ray photoelectron spectroscopy (XPS), Raman spectroscopy, UV-vis spectroscopy, Fourier transform infrared spectroscopy (FTIR), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The QCM immunosensor showed a linearity range (0.01-2.0 pg mL-1) and a low detection limit (3.33 fg mL-1). Lastly, high stable and selective QCM immunosensor was applied to prepared plasma samples with good recovery.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Antigen interleukin-6; QCM immunosensor; Sulfur-doped graphene quantum dot; h-ZnS-CdS NC

Mesh:

Substances:

Year:  2021        PMID: 33516376     DOI: 10.1016/j.aca.2021.338202

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Uniform Mass Sensitivity Distribution of Elliptically Designed Electrodes Based on a Quartz Crystal Microbalance.

Authors:  Haifeng Jiang; Longfei Tang
Journal:  ACS Omega       Date:  2021-11-23

Review 2.  Graphene-Based Biosensors for Molecular Chronic Inflammatory Disease Biomarker Detection.

Authors:  Isidro Badillo-Ramírez; Yojana J P Carreón; Claudia Rodríguez-Almazán; Claudia M Medina-Durán; Selene R Islas; José M Saniger
Journal:  Biosensors (Basel)       Date:  2022-04-14

3.  Novel nanosensor of cobalt(II) and copper(II) constructed from graphene quantum dots modified with Eriochrome Black T.

Authors:  Leila Vahab; Sajjad Keshipour
Journal:  Sci Rep       Date:  2022-08-01       Impact factor: 4.996

  3 in total