Literature DB >> 33513691

The Influence of Antiarrhythmic Device Intervention on Biopsychosocial Functioning and Anxiety in Patients with an Implanted Cardioverter Defibrillator.

Olimpia Karczewska1,2, Agnieszka Młynarska2.   

Abstract

Background and objectives: The aim of the study was to assess the impact of cardioverter-defibrillator interventions on the psychosocial functioning of a patient and the occurrence of concerns related to ICD. Materials and
Methods: The conducted study was a prospective and observational study that included 158 patients. The study was conducted in two stages: I before ICD implantation and II a follow-up visit six months after the ICD implantation. Standardized questionnaires were used in both stages.
Results: In the first six months, a cardioverter-defibrillator discharge occurred in 28 participants, which constituted 17.72% of the study group. The number of ICD discharges positively correlated to insomnia, symptoms of anxiety, symptoms of depression, more discharges, more severe insomnia, anxiety and depression. There was also a negative correlation between the number of discharges and the degree of disease acceptance and in the quality of life domains: somatic, mental, social and environmental. The more discharges, the worse the disease acceptance and assessment of the quality of life. Conclusions: Individuals who experienced discharges assessed their quality of life as worse in all aspects (perception of the quality of life, own health, physical, mental, social and environmental domains), experienced anxiety and depressive disorders more often, were characterized by a worse functioning in a chronic disease, experienced insomnia more often and reported more concerns related to ICD implantation.

Entities:  

Keywords:  anxiety; concerns; discharge; implantable cardioverter defibrillator; quality of life

Mesh:

Year:  2021        PMID: 33513691      PMCID: PMC7911262          DOI: 10.3390/medicina57020113

Source DB:  PubMed          Journal:  Medicina (Kaunas)        ISSN: 1010-660X            Impact factor:   2.430


  20 in total

1.  Concerns about the implantable cardioverter defibrillator: a determinant of anxiety and depressive symptoms independent of experienced shocks.

Authors:  Susanne S Pedersen; Ron T van Domburg; Dominic A M J Theuns; Luc Jordaens; Ruud A M Erdman
Journal:  Am Heart J       Date:  2005-04       Impact factor: 4.749

2.  Information provision, satisfaction and emotional distress in patients with an implantable cardioverter-defibrillator.

Authors:  Madelein T Hoogwegt; Jos W M G Widdershoven; Dominic A M J Theuns; Susanne S Pedersen
Journal:  Int J Cardiol       Date:  2014-08-30       Impact factor: 4.164

3.  Development of a measure of the concerns held by people with implanted cardioverter defibrillators: the ICDC.

Authors:  D J Frizelle; B Lewin; G Kaye; E D Moniz-Cook
Journal:  Br J Health Psychol       Date:  2006-05

4.  DS14: standard assessment of negative affectivity, social inhibition, and Type D personality.

Authors:  Johan Denollet
Journal:  Psychosom Med       Date:  2005 Jan-Feb       Impact factor: 4.312

5.  First inappropriate implantable cardioverter defibrillator therapy is often due to inaccurate device programming: analysis of the French OPERA registry.

Authors:  Antoine Leenhardt; Pascal Defaye; Elisabeth Mouton; Marc Delay; Nicolas Delarche; Jean-Marc Dupuis; Olivier Bizeau; Philippe Mabo; Saida Cheggour; Dominique Babuty
Journal:  Europace       Date:  2012-04-29       Impact factor: 5.214

6.  Prevalence and risk markers of early psychological distress after ICD implantation in the European REMOTE-CIED study cohort.

Authors:  Henneke Versteeg; Ivy Timmermans; Mathias Meine; Edgar Zitron; Philippe Mabo; Johan Denollet
Journal:  Int J Cardiol       Date:  2017-03-31       Impact factor: 4.164

7.  Gender differences in anxiety and concerns about the cardioverter defibrillator.

Authors:  Helle Spindler; Jens B Johansen; Kirsten Andersen; Peter Mortensen; Susanne S Pedersen
Journal:  Pacing Clin Electrophysiol       Date:  2009-05       Impact factor: 1.976

8.  Crosscultural adaptation and reliability testing of the Implantable Cardioverter-Defibrillator Concerns questionnaire to optimize the care of Polish patients with implantable cardioverter-defibrillators.

Authors:  Agnieszka Młynarska; Rafał Młynarski; Izabella Uchmanowicz; Ewa Marcisz-Dyla; Czesław Marcisz; Krzysztof Golba
Journal:  Kardiol Pol       Date:  2020-07-17       Impact factor: 3.108

9.  A comparison of anxiety, depression and quality of life between device shock and nonshock groups in implantable cardioverter defibrillator recipients.

Authors:  Fanny Jacq; Gael Foulldrin; Arnaud Savouré; Frédéric Anselme; Audrey Baguelin-Pinaud; Alain Cribier; Florence Thibaut
Journal:  Gen Hosp Psychiatry       Date:  2009-03-19       Impact factor: 3.238

10.  The Hospital Anxiety And Depression Scale.

Authors:  R Philip Snaith
Journal:  Health Qual Life Outcomes       Date:  2003-08-01       Impact factor: 3.186

View more
  1 in total

1.  Factors That Cause Concerns after Cardioverter Defibrillator Implantation.

Authors:  Olimpia Karczewska; Agnieszka Młynarska
Journal:  Int J Environ Res Public Health       Date:  2021-06-05       Impact factor: 3.390

  1 in total