Literature DB >> 33509601

Revision Total Knee Arthroplasty Using an Uncemented Metaphyseal Sleeve, Rotating Hinge Prosthesis: A Case Series of 99 Patients.

Karan Panesar1, Louay Al-Mouazzen1, Luthfun Nessa2, Sam C Jonas1, Sanjeev Agarwal1, Rhidian Morgan-Jones1.   

Abstract

BACKGROUND: Hinge knee replacement is a salvage procedure with historically high failure and complication rates. We aim to analyze the use of an uncemented metaphyseal sleeve revision knee replacement in our unit-a third-generation rotating hinge knee prosthesis. This is the largest reported series of this implant with longest follow up.
METHODS: We retrospectively identified 99 revision cases performed (2002-2018). In total, 67 of 99 (68%) cases were performed for aseptic etiology, whereas 32 of 99 (32%) cases were performed for infection. Clinical outcomes were assessed using the Oxford Knee Score, survivorship analysis, and incidence of revision/reoperations. Mean follow-up was 7 years (range 1.5-18).
RESULTS: At follow-up, the mean Oxford Knee Score had improved from 10 points to 25 points. At mean 7 years of follow up, 18 of 99 cases had undergone revision giving a survivorship of 81% (90% aseptic). In total, 10 of 18 cases were performed for infection (10%) and 9 of 18 cases were performed for aseptic reasons (9%), of which 5 were for patella resurfacing (2 revision), 2 for failure of bony ingrowth, and 1 for fracture. Twenty-six patients (26%) had complications postoperatively, with patella disorders and reduced range of movement the most common. Patients who did not undergo patella resurfacing were significantly more likely to need revision of any cause (P = .01).
CONCLUSION: This is the largest study of this prosthesis with longest follow-up. It demonstrates good survivorship and improvement in knee pain. Those with infection are at greatest risk of revision. Significant numbers have patella dysfunction/anterior knee symptoms therefore patella resurfacing should be considered when using this implant. LEVEL OF EVIDENCE: IV.
Copyright © 2021 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  SROM Noiles; metaphyseal sleeve; revision knee replacement; rotating hinge; survival

Year:  2021        PMID: 33509601     DOI: 10.1016/j.arth.2020.12.047

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

Review 1.  Metaphyseal cones and sleeves are similar in improving short- and mid-term outcomes in Total Knee Arthroplasty revisions.

Authors:  Umile Giuseppe Longo; Sergio De Salvatore; Giovanni Intermesoli; Francesco Pirato; Ilaria Piergentili; Roland Becker; Vincenzo Denaro
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-03-02       Impact factor: 4.342

Review 2.  Bone loss in aseptic revision total knee arthroplasty: management and outcomes.

Authors:  Thomas Bieganowski; Daniel B Buchalter; Vivek Singh; John J Mercuri; Vinay K Aggarwal; Joshua C Rozell; Ran Schwarzkopf
Journal:  Knee Surg Relat Res       Date:  2022-06-20

3.  Cones and sleeves present good survival and clinical outcome in revision total knee arthroplasty: a meta-analysis.

Authors:  Laura Theresa Fischer; Markus Heinecke; Eric Röhner; Peter Schlattmann; Georg Matziolis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-08-13       Impact factor: 4.114

4.  High ten-year implant survivorship and low patellofemoral complication rate for S-ROM rotating-hinge implants in revision total knee arthroplasty : a single-centre study.

Authors:  Hosam E Matar; Benjamin V Bloch; Peter J James
Journal:  Bone Jt Open       Date:  2022-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.