The difference between IgM and IgG antibody prevalence in different serological assays for COVID-19; lessons from the examination of healthcare workers.

Yurie Kobashi1, Yuzo Shimazu2, Yoshitaka Nishikawa3, Takeshi Kawamura4, Tatsuhiko Kodama5, Daiji Obara3, Masaharu Tsubokura6.   

Abstract

OBJECTIVES: The objective of this study was to investigate the differences between the results of two serology assays for detection of COVID-19 among medical staff, who are at higher risks of infection.
METHODS: The immunochromatography (ICG) rapid test kit and the chemiluminescence immunoassay (CLIA) quantitative antibody test were performed. The differences in IgM and IgG antibody prevalence in different serological assays were descriptively analyzed.
RESULTS: A total of 637 participants were included in this research. Two staff were IgM positive in the CLIA quantitative antibody test (cutoff value: 10 AU/ml) of 51 staff who were IgM positive in the rapid test kit. Six staff were IgG positive in the CLIA quantitative antibody test of 56 staff who were IgG positive in the rapid test kit. The proportion of antibody positive staff differed greatly between the rapid test kit and the CLIA quantitative antibody test.
CONCLUSIONS: There was a vast difference in the proportions of IgG and IgM antibody positive staff in the rapid test kit and the CLIA quantitative antibody test results. The results from the only rapid test kit might have to be interpreted with caution. Further studies to evaluate antibody testing accuracy are required to promote the understanding of each assay's characteristics and determine their purposes in each community.
Copyright © 2020 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Antibody prevalence; COVID-19; Serological assay

Mesh:

Substances:

Year:  2020        PMID: 33508702      PMCID: PMC7836839          DOI: 10.1016/j.intimp.2020.107360

Source DB:  PubMed          Journal:  Int Immunopharmacol        ISSN: 1567-5769            Impact factor:   5.714


Introduction

The COVID-19 pandemic is an ongoing global pandemic caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). To end this pandemic, various serologic assays including the chemiluminescence immunoassay (CLIA) and immunochromatography (ICG) assay have been developed. In particular, antibody tests are useful for evaluating the extent of the disease in the population, infection control, assessing the effects of a new vaccination, and as a marker of advancing in severity of COVID-19 [1], [2], [3]. Further, it was reported that higher levels of serological assay readings have been seen in those with symptoms and those with severe diseases, while asymptomatic infections demonstrate a variable response [4]. Thus, improving the accuracy of antibody tests and increasing its usage in communities has become a vital public health issue in recent times. Meanwhile, how antibody tests can be effectively utilized is under discussion mainly because sensitivity, specificity, or threshold vary between each assay and different products of the same assay [1], [5], [6], [7], [8], [9]. Since the results differ depending on the method and the test used, it is necessary to gather information on the differences in results for different antibody tests for future use. Nevertheless, most antibody test surveys within communities have been evaluated using a single assay or a single production. Furthermore, a few studies have been conducted to compare the results of different antibody tests from communities and when done on a large-scale basis [10]; however, the number of such studies is limited. Thus, the objective of this study was to investigate the differences between the results of the rapid COVID-19 test kit and the CLIA quantitative antibody test among medical staff, who are at higher risks of infection. To this end, this study set out to evaluate the concordance between a lab-based assay and a point-of-care rapid test kit assay in an asymptomatic but high-risk population.

Method

Seireikai group is a private health care group located in the central part of Fukushima Prefecture, Japan. It runs Hirata Central Hospital, which has 142 beds for inpatients and is located in Hirata Village, approximately 190 km north of Tokyo. The immunochromatography rapid test kit and the CLIA quantitative antibody test were performed on 680 hospital staff to identify COVID-19 infection statuses; of these, we set aside the 637 participants who worked as Seireikai group staff and agreed to participate in this study. The blood sample for each test was obtained between 8 May and 28 May 2020 in Fukushima Prefecture, where approximately 1850 thousand residents live and 81 COVID-19 cases has been reported as of 28 May 2020 [11]. The 2019-nCoV IgG/IgM kit made by Vazyme Biotech Co., LTD (YHLO Biotech, Shenzhen, China) was used for the rapid test. The testing method process was followed by the official testing method adequately [12]. The serum was used for the examination. Two independent laboratory technicians certified the line judgment. The CLIA quantitative antibody test was performed using a high throughput assay apparatus, called iFlash 3000, and with assay reagents, iFlash-SARS-CoV-2 IgM/IgG (YHLO Biotech, Shenzhen, China). The testing method process was as per official guidelines. (Refer to the official instruction manual for iFlash Immunoassay Analyzer for SARS-CoV-2 IgG and IgM). The cutoff of the CLIA quantitative antibody test was 10 AU/ml. S antigen, which may induce the production of neutralizing antibodies, as well as N antigen were targets for the antibody test. Moreover, the samples for the CLIA quantitative antibody test and rapid test were obtained at the same time (see Table 1 ).
Table 1

Participants characteristics.

Number%
Gender
 Female48375.82
 Male15424.18



Age
 18–4432450.86
 45–6426541.6
 65–78487.54



Occupation
 Doctor152.35
 Nurse11217.58
 Caregiver27543.17
 Other medical staff6610.36
 Office worker518.01
 Other non-medical staff11818.52



Working place
 Hospital16025.12
 Clinic538.32
 Long term care health facility37158.24
 Nursery school223.45
 Other314.87



IgM in Immunochromatography kit test
 Positive518.01
 Negative58691.99



IgG in Immunochromatography kit test
 Positive568.79
 Negative58191.21



IgM in CLIA quantitative test
 Positive20.31
 Negative63599.69



IgG in CLIA quantitative test
 Positive60.94
 Negative63199.06

CLIA = chemiluminescence immunoassay.

Participants characteristics. CLIA = chemiluminescence immunoassay. The quality check test was performed every day before measuring the CLIA samples. The expected value and the confidential range of the calibration reagent for each lot were determined by the company, and the tests for participants were performed after confirming that the values were within the decided range. The data for the value of the calibration reagent on each day are shown in the supplemental table 1. The CLIA quantitative antibody tests of the participants were performed on three different days. Further, reverse transcription polymerase chain reaction (RT-PCR) was employed using the LightCycler® 480 Instrument II [13]. The differences in IgM and IgG antibody prevalence in different serological assays were descriptively analyzed using STATA IC15 (Lightstone, Texas USA, version15). This study was approved by the ethics committee of Hirata Central Hospital (Ethics Committee ID: 2020-0427-1), and all participants individually provided written informed consent.

Results

A total of 637 participants were included in this research. The median age [25th, 75th centiles] of participants was 44 [34, 56], and the proportion of males was 24.18% (n = 154). Fig. 1(a) shows the results of the IgM test. Two staff members were positive in the CLIA quantitative antibody test (cutoff value: 10 AU/ml) of the 51 staff members who were IgM positive in the rapid test kit. The proportions of IgM positives in the rapid test kit for each range of the CLIA quantitative antibody test results were 4.3% (0–0.5 AU/ml), 2.6% (0.5–1.0 AU/ml), 13.9% (1.0–1.5 AU/ml), 18.5% (1.5–2.0 AU/ml), 0.0% (2.0–2.5 AU/ml), 40.9% (2.5–5.0 AU/ml), 70.0% (5.0–7.5 AU/ml), and 100.00% (over10 AU/ml).
Fig. 1

The results of the chemiluminescence immunoassay quantitative antibody test (AU/ml). (a) IgM, (b) IgG. The cut off value of this chemiluminescence immunoassay quantitative antibody test is 10AU/ml. ICG = immunochromatography, CLIA = Chemiluminescence immunoassay.

The results of the chemiluminescence immunoassay quantitative antibody test (AU/ml). (a) IgM, (b) IgG. The cut off value of this chemiluminescence immunoassay quantitative antibody test is 10AU/ml. ICG = immunochromatography, CLIA = Chemiluminescence immunoassay. Fig. 1(b) shows the results of the IgG test. Six staff members were positive in the CLIA quantitative antibody test (cutoff value: 10 AU/ml) of the 56 staff members who were IgG positive in the rapid test kit. The proportions of IgG positive in the rapid test kit for each range of the quantitative antibody test results were 2.7% (0–0.5 AU/ml), 5.6% (0.5–1.0 AU/ml), 7.8% (1.0–1.5 AU/ml), 9.6% (1.5–2.0 AU/ml), 14.3% (2.0–2.5 AU/ml), 31.4% (2.5–5.0 AU/ml), 50.0% (5.0–7.5 AU/ml), 33.33% (7.5–10 AU/ml), and 100.0% (over10 AU/ml). The IgG antibody prevalence ratio among health care workers in the rural area of Fukushima Prefecture was 0.9% based on the CLIA quantitative antibody test. A RT-PCR assay was performed for 51 participants who were IgM-positive with the rapid test kit, and the results were all negative. However, the findings of IgM positives in the rapid test and RT-PCR negative individuals does not mean that there were false positive IgM bands in the rapid kit tests in each case because the term from infection to appearing positive results is different for each assay [14]. Moreover, all the staff members did not have any subjective symptoms related to COVID-19 during the survey period. Additionally, none were confirmed to have COVID-19 in the following two months after the survey. This means that these tests were conducted on asymptomatic populations.

Discussion

The proportion of antibody positive staff differed greatly between the rapid test kit and the CLIA quantitative antibody test (8.8% in the rapid test kit and 0.9% in the CLIA quantitative antibody test for IgG; 8.0% and 0.3% for IgM). Thus, the results from the rapid test kit might have to be interpreted with caution. This study suggested that detailed data on the sensitivity of positive control among the subclinical infection population and the specificity of negative control among the absolutely non-infected population are required for each test. Moreover, the 2019-nCoV IgG/IgM detection kit by Vazyme Biotech Co., Ltd. used in this study reported a sensitivity of 92% and a specificity of 97%; however, the positive control was set within the population that had developed severe symptoms of COVID-19 following hospitalization. For an epidemiological study of COVID-19 to determine the proportion of subclinical infections, it is necessary to consistently evaluate the sensitivity of subclinical infections with the serum of people who have not had any symptoms with positive RT-PCR results as a positive control, as well as specificity with the serum before COVID-19 as a negative control. Whenever rapid test kits are used in hospitals and communities, it is crucial to decide in advance as to how participants who have tested IgM positive are to be handled. In the present study, RT-PCR tests were performed on all IgM-positive participants for risk management of a possible outbreak of COVID-19 among hospital staff. However, the evaluation of IgM using rapid test kits for diagnosis has proved difficult in previous studies [1], [5], [15]. When the 2019-nCoV IgG/IgM detection kit by Vazyme Biotech Co., Ltd, is used in hospitals or communities, it might be a plausible option for the rapid test kit results to be focused only on the IgG rather than IgG and IgM. Additionally, to avoid confusion, these assays need to be independently evaluated prior to use, and must be used for a minimum population size against PT-PCR positive results within a suitable time frame post the RT-PCR results. Nevertheless, antibody tests have had positive effects; for instance, in this study, staff awareness of COVID-19 increased post testing. This is because the staff was widely notified about the purpose of this antibody test to protect the safety of patients and to raise their awareness about the exact situations in hospitals. It is thus vital to inform the community on the purpose of antibody testing, so that the tests have a positive effect, rather than cause anxiety relating to test results and confusion. This study has some limitations. First, when interpreting these findings, the possibility that the cross reactions with other coronaviruses might have caused the higher seroprevalence in the rapid test should be considered. Second, the confirmatory virus neutralization test was not performed in the present study. Third, the differences in the target antigen might affect the differences in the results from each test. Fourth, while a clear correlation was not found between quantitative antibody test values and rapid test line density, the present study did not have enough quality record of band intensity to assess.

Conclusion

There was a vast difference in the proportions of IgG and IgM antibody positive staff in the rapid test kit and the CLIA quantitative antibody test results. Further studies to evaluate antibody testing accuracy are required to promote the understanding of each assay's characteristics and determine their purposes in each community. Additionally, an epidemiological survey is required to further the discussion on the effective usage of antibody assays and infection control.

Funding sources

This research did not receive any specific grant from any funding agency in the public, commercial, or not-for-profit sector.

Author contributions

All the authors made a substantial contribution to this research. YK and TM contributed to writing the paper. All members contributed to the study design, data collection, and coordination with local stakeholders.

Declaration of Competing Interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
  12 in total

1.  Towards the rational utilization of SARS-CoV-2 serological tests in clinical practice.

Authors:  Mario Plebani; Andrea Padoan; Laura Sciacovelli; Daniela Basso
Journal:  Clin Chem Lab Med       Date:  2020-09-25       Impact factor: 3.694

Review 2.  Diagnostic performance of COVID-19 serology assays.

Authors:  Z Zainol Rashid; S N Othman; M N Abdul Samat; U K Ali; K K Wong
Journal:  Malays J Pathol       Date:  2020-04       Impact factor: 0.656

3.  Diagnostic performance of seven rapid IgG/IgM antibody tests and the Euroimmun IgA/IgG ELISA in COVID-19 patients.

Authors:  J Van Elslande; E Houben; M Depypere; A Brackenier; S Desmet; E André; M Van Ranst; K Lagrou; P Vermeersch
Journal:  Clin Microbiol Infect       Date:  2020-05-28       Impact factor: 8.067

4.  Testing for Novel Coronavirus Antibodies: A Necessary Adjunct.

Authors:  Marco Daverio; Angela Amigoni; Maria Elena Cavicchiolo
Journal:  J Infect Dis       Date:  2020-07-06       Impact factor: 5.226

5.  Immune Phenotyping Based on the Neutrophil-to-Lymphocyte Ratio and IgG Level Predicts Disease Severity and Outcome for Patients With COVID-19.

Authors:  Bicheng Zhang; Xiaoyang Zhou; Chengliang Zhu; Yuxiao Song; Fan Feng; Yanru Qiu; Jia Feng; Qingzhu Jia; Qibin Song; Bo Zhu; Jun Wang
Journal:  Front Mol Biosci       Date:  2020-07-03

6.  Evaluation of two automated and three rapid lateral flow immunoassays for the detection of anti-SARS-CoV-2 antibodies.

Authors:  Isabel Montesinos; Damien Gruson; Benoit Kabamba; Hafid Dahma; Sigi Van den Wijngaert; Soleimani Reza; Vincenzo Carbone; Olivier Vandenberg; Beatrice Gulbis; Fleur Wolff; Hector Rodriguez-Villalobos
Journal:  J Clin Virol       Date:  2020-05-05       Impact factor: 3.168

7.  Test performance evaluation of SARS-CoV-2 serological assays.

Authors:  Jeffrey D Whitman; Joseph Hiatt; Cody T Mowery; Brian R Shy; Ruby Yu; Tori N Yamamoto; Ujjwal Rathore; Gregory M Goldgof; Caroline Whitty; Jonathan M Woo; Antonia E Gallman; Tyler E Miller; Andrew G Levine; David N Nguyen; Sagar P Bapat; Joanna Balcerek; Sophia A Bylsma; Ana M Lyons; Stacy Li; Allison Wai-Yi Wong; Eva Mae Gillis-Buck; Zachary B Steinhart; Youjin Lee; Ryan Apathy; Mitchell J Lipke; Jennifer Anne Smith; Tina Zheng; Ian C Boothby; Erin Isaza; Jackie Chan; Dante D Acenas; Jinwoo Lee; Trisha A Macrae; Than S Kyaw; David Wu; Dianna L Ng; Wei Gu; Vanessa A York; Haig Alexander Eskandarian; Perri C Callaway; Lakshmi Warrier; Mary E Moreno; Justine Levan; Leonel Torres; Lila A Farrington; Rita Loudermilk; Kanishka Koshal; Kelsey C Zorn; Wilfredo F Garcia-Beltran; Diane Yang; Michael G Astudillo; Bradley E Bernstein; Jeffrey A Gelfand; Edward T Ryan; Richelle C Charles; A John Iafrate; Jochen K Lennerz; Steve Miller; Charles Y Chiu; Susan L Stramer; Michael R Wilson; Aashish Manglik; Chun Jimmie Ye; Nevan J Krogan; Mark S Anderson; Jason G Cyster; Joel D Ernst; Alan H B Wu; Kara L Lynch; Caryn Bern; Patrick D Hsu; Alexander Marson
Journal:  medRxiv       Date:  2020-05-17

8.  Antibody Responses to SARS-CoV-2 in Patients With Novel Coronavirus Disease 2019.

Authors:  Juanjuan Zhao; Quan Yuan; Haiyan Wang; Wei Liu; Xuejiao Liao; Yingying Su; Xin Wang; Jing Yuan; Tingdong Li; Jinxiu Li; Shen Qian; Congming Hong; Fuxiang Wang; Yingxia Liu; Zhaoqin Wang; Qing He; Zhiyong Li; Bin He; Tianying Zhang; Yang Fu; Shengxiang Ge; Lei Liu; Jun Zhang; Ningshao Xia; Zheng Zhang
Journal:  Clin Infect Dis       Date:  2020-11-19       Impact factor: 9.079

9.  Diagnostic performances and thresholds: The key to harmonization in serological SARS-CoV-2 assays?

Authors:  Mario Plebani; Andrea Padoan; Davide Negrini; Benedetta Carpinteri; Laura Sciacovelli
Journal:  Clin Chim Acta       Date:  2020-05-30       Impact factor: 3.786

10.  COVID-19: a meta-analysis of diagnostic test accuracy of commercial assays registered in Brazil.

Authors:  Rodolfo Castro; Paula M Luz; Mayumi D Wakimoto; Valdilea G Veloso; Beatriz Grinsztejn; Hugo Perazzo
Journal:  Braz J Infect Dis       Date:  2020-04-18       Impact factor: 3.257

View more
  6 in total

Review 1.  SARS-CoV-2 seroprevalence around the world: an updated systematic review and meta-analysis.

Authors:  Mobin Azami; Yousef Moradi; Asra Moradkhani; Abbas Aghaei
Journal:  Eur J Med Res       Date:  2022-06-02       Impact factor: 4.981

2.  Factors Associated with COVID-19 Vaccine Booster Hesitancy: A Retrospective Cohort Study, Fukushima Vaccination Community Survey.

Authors:  Makoto Yoshida; Yurie Kobashi; Takeshi Kawamura; Yuzo Shimazu; Yoshitaka Nishikawa; Fumiya Omata; Tianchen Zhao; Chika Yamamoto; Yudai Kaneko; Aya Nakayama; Morihito Takita; Naomi Ito; Moe Kawashima; Sota Sugiura; Kenji Shibuya; Shingo Iwami; Kwangsu Kim; Shoya Iwanami; Tatsuhiko Kodama; Masaharu Tsubokura
Journal:  Vaccines (Basel)       Date:  2022-03-26

3.  Factors associated with anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein antibody titer and neutralizing activity among healthcare workers following vaccination with the BNT162b2 vaccine.

Authors:  Yurie Kobashi; Yuzo Shimazu; Takeshi Kawamura; Yoshitaka Nishikawa; Fumiya Omata; Yudai Kaneko; Tatsuhiko Kodama; Masaharu Tsubokura
Journal:  PLoS One       Date:  2022-06-10       Impact factor: 3.752

Review 4.  Understanding neutralising antibodies against SARS-CoV-2 and their implications in clinical practice.

Authors:  Natalie Yan-Lin Pang; Alexander Shao-Rong Pang; Vincent T Chow; De-Yun Wang
Journal:  Mil Med Res       Date:  2021-08-31

5.  A pilot clinical validation study of a self-collected vaginal swab device for the detection of chlamydia trachomatis in women.

Authors:  Michael Muljadi; Chao-Min Cheng; Chung-Yao Yang; Ting-Chang Chang; Ching-Ju Shen
Journal:  Front Bioeng Biotechnol       Date:  2022-10-04

6.  Time course of adverse reactions following BNT162b2 vaccination in healthy and allergic disease individuals aged 5-11 years and comparison with individuals aged 12-15 years: an observational and historical cohort study.

Authors:  Makoto Yoshida; Yurie Kobashi; Yuzo Shimazu; Hiroaki Saito; Chika Yamamoto; Takeshi Kawamura; Masatoshi Wakui; Kenzo Takahashi; Naomi Ito; Yoshitaka Nishikawa; Tianchen Zhao; Masaharu Tsubokura
Journal:  Eur J Pediatr       Date:  2022-10-13       Impact factor: 3.860

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.