Project hyperopic power prediction: accuracy of 13 different concepts for intraocular lens calculation in short eyes.

Jascha Wendelstein1, Peter Hoffmann2, Nino Hirnschall3, Isaak Raphael Fischinger4,5, Siegfried Mariacher1, Tina Wingert1, Achim Langenbucher6, Matthias Bolz1.   

Abstract

PURPOSE: To evaluate the accuracy of intraocular lens (IOL) power calculation in a patient cohort with short axial eye length to assess the performance of IOL power calculation schemes in strong hyperopes.
METHODOLOGY: The study was a single centre, single surgeon retrospective consecutive case series at the Augen- und Laserklinik, Castrop-Rauxel, Germany. Inclusion of patients after uneventful cataract surgery implanting either spherical (SA60AT) or aspheric (ZCB00) IOLs. Inclusion criteria were axial eye length <21.5 mm and/or emmetropising IOL power >28.5 D. Lens constants were optimised on a separate patient cohort considering the full bandwidth of axial eye length. Data of one single eye per patient were randomly included. The outcome measures were: mean absolute prediction error (MAE), median absolute prediction error, mean prediction error with SD and median prediction error and the percentage of eyes with an MAE within 0.25 D, 0.5 D, 0.75 D and 1.0 D.
RESULTS: A total of 150 eyes from 150 patients were assessed. Okulix, PEARL-DGS, Kane and Castrop provided a statistically significantly smaller MAE compared with the Hoffer Q and SRK/T formulae.
CONCLUSION: In our patient cohort with short axial eye length, the use of PEARL-DGS, Okulix, Kane or Castrop formulae showed the lowest MAE. The Castrop formula has not been published before, but will be disclosed with a ready-to-use Excel sheet as an addendum to this paper. © Author(s) (or their employer(s)) 2022. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  lens and zonules; optics and refraction; posterior chamber

Mesh:

Year:  2021        PMID: 33504489     DOI: 10.1136/bjophthalmol-2020-318272

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   5.908


  4 in total

1.  Accuracy of new-generation intraocular lens calculation formulas in eyes with variations in predicted refraction.

Authors:  Pingjun Chang; Shuyi Qian; Yalan Wang; Siyan Li; Fuman Yang; Yiwen Hu; Zhuohan Liu; Yun-E Zhao
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-07-08       Impact factor: 3.117

2.  Comparing the accuracy of new intraocular lens power calculation formulae in short eyes after cataract surgery: a systematic review and meta-analysis.

Authors:  Yu Luo; Hongyu Li; Lixiong Gao; Jinlin Du; Wenqian Chen; Yi Gao; Zi Ye; Zhaohui Li
Journal:  Int Ophthalmol       Date:  2022-01-26       Impact factor: 2.031

3.  Similarity of eyes in a cataractous population-How reliable is the biometry of the fellow eye for lens power calculation?

Authors:  Achim Langenbucher; Nóra Szentmáry; Alan Cayless; Veronika Röggla; Christina Leydolt; Jascha Wendelstein; Peter Hoffmann
Journal:  PLoS One       Date:  2022-06-30       Impact factor: 3.752

4.  Strategies for formula constant optimisation for intraocular lens power calculation.

Authors:  Achim Langenbucher; Nóra Szentmáry; Alan Cayless; Jascha Wendelstein; Peter Hoffmann
Journal:  PLoS One       Date:  2022-05-05       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.