Assessment of the Kernel Gram Matrix Representation of Data in Order to Avoid the Alignment of Chromatographic Signals.

Ivana Stanimirova1, Michal Daszykowski1.   

Abstract

This article discusses the possibility of exploratory data analysis of samples described by second-order chromatographic data affected by peak shifts. In particular, the potential of the kernel Gram matrix representation as an alternative to the necessary and time-consuming alignment step is evaluated. It was demonstrated through several simulation studies and comparisons that even small peak shifts can be a substantial source of data variance, and they can easily hamper the interpretation of chromatographic data. When peak shifts are small, their negative effect is far more destructive than the impact of relatively large levels of the Gaussian noise, heteroscedastic noise, and signal's baseline. The Gram principal component analysis approach has proven to be a well-suited tool for exploratory analysis of chromatographic signals collected using the diode-array detector in which sample-to-sample peak shifts were observed.

Entities:  

Keywords:  Gram PCA; chemical fingerprints; diode-array detector; kernel trick; multichannel detector; peak shifts; preprocessing; second-order data; warping

Mesh:

Year:  2021        PMID: 33504096      PMCID: PMC7865539          DOI: 10.3390/molecules26030621

Source DB:  PubMed          Journal:  Molecules        ISSN: 1420-3049            Impact factor:   4.411


  5 in total

1.  Target selection for alignment of chromatographic signals obtained using monochannel detectors.

Authors:  M Daszykowski; B Walczak
Journal:  J Chromatogr A       Date:  2007-11-06       Impact factor: 4.759

2.  Matrix correlations for high-dimensional data: the modified RV-coefficient.

Authors:  A K Smilde; H A L Kiers; S Bijlsma; C M Rubingh; M J van Erk
Journal:  Bioinformatics       Date:  2008-12-10       Impact factor: 6.937

3.  Second-order advantage obtained from standard addition first-order instrumental data and multivariate curve resolution-alternating least squares. Calculation of the feasible bands of results.

Authors:  Naimeh Mohseni; Morteza Bahram; Alejandro C Olivieri
Journal:  Spectrochim Acta A Mol Biomol Spectrosc       Date:  2013-12-05       Impact factor: 4.098

4.  No-alignment-strategies for exploring a set of two-way data tables obtained from capillary electrophoresis-mass spectrometry.

Authors:  M Daszykowski; R Danielsson; B Walczak
Journal:  J Chromatogr A       Date:  2008-03-15       Impact factor: 4.759

Review 5.  Multi-way chromatographic calibration-A review.

Authors:  Graciela M Escandar; Alejandro C Olivieri
Journal:  J Chromatogr A       Date:  2019-01-09       Impact factor: 4.759

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.