Literature DB >> 33502256

Endogenous anti-streptavidin antibodies causing erroneous laboratory results more common than anticipated.

Louise K Dahll1, Ellen Marie Haave1, Sandra R Dahl1, Finn Erik Aas1, Per M Thorsby1.   

Abstract

All immunological methods are vulnerable to different kinds of interference. The purpose of this work was to study the cause and frequency of method-dependent interference in the Roche thyroid immunoassays. Serum samples with discordant thyroid function tests (TFT) were selected from samples sent to the Hormone Laboratory, Oslo University Hospital from June 2013 to September 2018. We identified 93 patients with discordant pathological TFT when analysed with the Roche methods and normal results when analysed with alternative methods. 42 of these samples were sent to Roche Diagnostics (Germany) for investigation of the interfering substance. Roche found interference to be caused by the presence of endogenous anti-streptavidin antibodies (ASA) (34 of 42 patients), ruthenium or the idiotype of the ruthenium labelled antibody (3 of 42 patients) and mouse antigens (1 of 42 patients). Method-dependent interference was estimated to affect 0.37% of the patients investigated in our laboratory. Interference due to the presence of endogenous ASA were further explored in other (non-thyroid) immunoassays by comparing analyte levels before and after pre-adsorption of the patients' sera with streptavidin-coated paramagnetic beads. An underestimation of hormone levels was observed in sandwich immunoassays, while an overestimation was found in competitive assays. Method-dependent interference in Roche thyroid immunoassays is caused mainly by ASA and is not a very rare phenomenon. Misleading results may lead to misdiagnosis and inappropriate medical treatment. The supplier of the assay should be alerted when the available alternative methodology reveals method-dependent errors.

Entities:  

Keywords:  ruthenium; Immunoassay; antibody; biotin; streptavidin

Mesh:

Substances:

Year:  2021        PMID: 33502256     DOI: 10.1080/00365513.2020.1858493

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  2 in total

1.  The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay.

Authors:  Ruhan Wei; Kathleen Bowers; Grace M Kroner; Drew Payto; Jessica M Colón-Franco
Journal:  Pract Lab Med       Date:  2022-05-10

Review 2.  Hormone Immunoassay Interference: A 2021 Update.

Authors:  Khaldoun Ghazal; Severine Brabant; Dominique Prie; Marie-Liesse Piketty
Journal:  Ann Lab Med       Date:  2022-01-01       Impact factor: 3.464