Literature DB >> 33502041

Evaluation of Fetal Cardiac Size and Shape: A New Screening Tool to Identify Fetuses at Risk for Tetralogy of Fallot.

Greggory R DeVore1, Gary M Satou2, Yalda Afshar1, Danielle Harake2, Mark Sklansky2.   

Abstract

OBJECTIVE: Prenatal detection rates for tetralogy of Fallot (TOF) vary between 23 and 85.7%, in part because of the absence of significant structural abnormalities of the 4-chamber view (4CV), as well as the relative difficulty in detection of abnormalities during the screening examination of the outflow tracts. The purpose of this study was to evaluate whether the 4CV and ventricles in fetuses with TOF may be characterized by abnormalities of size and shape of these structures.
METHODS: This study retrospectively evaluated 44 fetuses with the postnatal diagnosis of TOF. Measurements were made from the 4CV (end-diastolic length, width, area, global sphericity index, and cardiac axis) and the right (RV) and left (LV) ventricles (area, length, 24-segment transverse widths, sphericity index, and RV/LV ratios). Logistic regression analysis was performed to identify variables that might separate fetuses with TOF from normal controls.
RESULTS: The mean gestational age at the time of the last examination prior to delivery was 28 weeks 5 days (SD 4 weeks, 4 days). The mean z-scores were significantly lower in fetuses with TOF for the 4CV and RV and LV measurements of size and shape. Logistic regression analysis identified simple linear measurements of the 4CV, RV, and LV that had a sensitivity of 90.9 and specificity of 98.5% that outperformed the 4CV cardiac axis (sensitivity of 22.7%) as a screening tool for TOF.
CONCLUSIONS: Measurements of the 4CV, RV, and LV can be used as an adjunct to the outflow tract screening examination to identify fetuses with TOF.
© 2021 American Institute of Ultrasound in Medicine.

Keywords:  Tetralogy of Fallot; fetal echocardiography; fetal heart; prenatal diagnosis; speckle tracking

Year:  2021        PMID: 33502041     DOI: 10.1002/jum.15639

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  2 in total

1.  Feasibility of 4D-Spatio Temporal Image Correlation (STIC) in the Comprehensive Assessment of the Fetal Heart Using FetalHQ®.

Authors:  Laura Nogué; Olga Gómez; Nora Izquierdo; Cristina Mula; Narcís Masoller; Josep M Martínez; Eduard Gratacós; Greggory Devore; Fàtima Crispi; Mar Bennasar
Journal:  J Clin Med       Date:  2022-03-04       Impact factor: 4.241

2.  Identification of circRNA-miRNA-mRNA Regulatory Network and Crucial Signaling Pathway Axis Involved in Tetralogy of Fallot.

Authors:  Zunqi Kan; Wenli Yan; Ning Wang; Yuqing Fang; Huanyu Gao; Yongmei Song
Journal:  Front Genet       Date:  2022-07-07       Impact factor: 4.772

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.