Literature DB >> 33497961

Taper junctions in modular hip joint replacements: What affects their stability?

Ulrike Mueller1, Therese Bormann2, Stefan Schroeder3, J Philippe Kretzer4.   

Abstract

BACKGROUND: Although taper junctions are beneficial in the reconstruction of hip joints, some clinical concerns like the formation of adverse local tissue reactions have recently emerged. These reactions are associated with wear and corrosion products from the interface of insufficient taper connections regarding strength. Commonly used tapers vary in their geometric and topographical design parameter. Therefore, this study aims to evaluate interactions between design and surgical related parameters to the taper connection strength.
METHODS: In this study, the effect of the taper contact situation, surface roughness and head material in combination with assembly force on the taper connection strength were assessed using torque-off tests. Furthermore, the type of use in terms of single-use or re-use of the stem taper was investigated.
RESULTS: The study showed that the impaction force is the predominant factor that determines the taper strength followed by the type of use and the head material. The contact situation seems to slightly influence the determined torque-off moment, whereas the surface topography of the stem taper obviously plays a minor role for the taper connection strength.
CONCLUSION: Clinical users should be aware that an increased assembly force will strengthen the stability of the taper junction, whereas care should be taken when reusing hip stems with metal heads as this may decrease their connection strength.
Copyright © 2021 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Head-stem junction; Modularity; Taper; Taper angle difference; Topography; Torque-off moments; Total hip arthroplasty (THA)

Mesh:

Year:  2021        PMID: 33497961     DOI: 10.1016/j.jmbbm.2020.104258

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  3 in total

Review 1.  EFORT recommendations for off-label use, mix & match and mismatch in hip and knee arthroplasty.

Authors:  Keith Tucker; Klaus-Peter Günther; Per Kjaersgaard-Andersen; Jörg Lützner; Jan Philippe Kretzer; Rob G H H Nelissen; Toni Lange; Luigi Zagra
Journal:  EFORT Open Rev       Date:  2021-11-19

2.  Variability in stem taper surface topography affects the degree of corrosion and fretting in total hip arthroplasty.

Authors:  Kilian Elia Stockhausen; Christoph Riedel; Alex Victoria Belinski; Dorothea Rothe; Thorsten Gehrke; Felix Klebig; Matthias Gebauer; Michael Amling; Mustafa Citak; Björn Busse
Journal:  Sci Rep       Date:  2021-04-30       Impact factor: 4.379

3.  Importance of surgical assembly technique on the engagement of 12/14 modular tapers.

Authors:  A Wade; F Webster; A R Beadling; M G Bryant
Journal:  Proc Inst Mech Eng H       Date:  2021-10-25       Impact factor: 1.617

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.