Literature DB >> 33495781

Long-term durability of bicuspid aortic valve repair: a comparison of 2 annuloplasty techniques.

Christophe de Meester1, Jean-Louis Vanovershelde1,2, Jama Jahanyar3, Saadallah Tamer3, Stefano Mastrobuoni1,3, Michel Van Dyck4, Emiliano Navarra1,3, Alain Poncelet1,3, Parla Astarci1,3, Gebrine El Khoury1,3, Laurent de Kerchove1,3.   

Abstract

OBJECTIVES: To compare long-term outcomes after bicuspid aortic valve (BAV) repair utilizing the Cabrol annuloplasty versus valve sparing Reimplantation technique.
METHODS: From 1996 to 2018, 340 consecutive patients underwent BAV repair. Eighty underwent Cabrol annuloplasty and 189 underwent Reimplantation. Exclusion criteria were re-repairs (n = 6), active endocarditis (n = 4), no annuloplasty (n = 41) and ring or suture annuloplasty (n = 20). We compared both groups for survival, reoperations, valve related events and recurrent severe aortic regurgitation (AR > 2+). Inverse probability weighting (IPW) was used to balance the 2 groups. Cox regression analysis was used to identify outcome predictors.
RESULTS: After weighting, pre- and intraoperative characteristics were similar between groups, except for aorta replacement techniques and operative time, which was longer in the Reimplantation group (P < 0.001). At 12 years, overall survival was similar between groups (IPW: Cabrol 97 ± 2% vs Reimplantation 94 ± 3%, P = 0.52). Freedom from reoperation and freedom from AR > 2+ were significantly lower in the Cabrol group (reoperation IPW: 69 ± 9% vs 91 ± 4%, P = 0.004 and AR > 2+ IPW: 71 ± 8% vs 97 ± 2%, P < 0.001). The Reimplantation technique was the only independent predictor of reoperation (hazard ratio 0.31; confidence interval 0.19-0.7; P = 0.005).
CONCLUSIONS: In this study, comparing 2 annuloplasty strategies for BAV repair, we found statistically significant differences in long-term durability favouring the Reimplantation technique, and no differences in overall survival. The results support our current strategy of Reimplantation technique and repair of AR in patients with BAV. Cabrol annuloplasty is obsolete and should be generally abandoned in patients undergoing BAV repair for AR.
© The Author(s) 2021. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Annuloplasty; Bicuspid; Valve repair; Valve sparing

Mesh:

Year:  2021        PMID: 33495781     DOI: 10.1093/ejcts/ezaa471

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  6 in total

1.  Reply: Reimplantation should be the gold standard to treat the regurgitant bicuspid aortic valve.

Authors:  Tirone E David
Journal:  JTCVS Tech       Date:  2022-04-11

2.  Reply: Only randomized trials can define the gold standard.

Authors:  Giovanni Jr Soletti; Mario Gaudino
Journal:  JTCVS Tech       Date:  2022-04-12

3.  Reimplantation should be the gold standard to treat the regurgitant bicuspid aortic valve.

Authors:  Jama Jahanyar; Gebrine El Khoury; Laurent de Kerchove
Journal:  JTCVS Tech       Date:  2022-04-12

4.  A rare case of pseudo-quadricuspid aortic valve repair.

Authors:  Maureen Klepper; Jama Jahanyar; Gaby Aphram; Laurent de Kerchove; Gebrine El Khoury
Journal:  JTCVS Tech       Date:  2021-10-26

5.  Tailoring the Ross procedure for patients with aortic regurgitation.

Authors:  Amine Mazine; Ismail El-Hamamsy
Journal:  JTCVS Tech       Date:  2021-06-08

6.  Bicuspid aortic valve repair: the 180°-Reimplantation technique.

Authors:  Jama Jahanyar; Laurent de Kerchove; Gebrine El Khoury
Journal:  Ann Cardiothorac Surg       Date:  2022-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.