Literature DB >> 3349552

Comparison of circle absorber and Jackson-Rees systems for paediatric anaesthesia.

D K Rasch1, L Bunegin, J Ledbetter, D Kaminskas.   

Abstract

To evaluate effects of anaesthesia delivery systems on respiratory work in infants, we measured end-tidal PCO2 (PETCO2), transcutaneous PCO2 (PTcCO2) respiratory rate and arterial blood gases in infants (ages 0.2 to 23.8 months) anaesthetised with either a Jackson-Rees (n = 11) or paediatric circle absorber system (n = 15). Two hours after induction, with assisted ventilation there was no difference in PETCO2, PTcCO2, respiratory rate, pH or PaCO2 in infants anaesthetised with either system. In the laboratory, we measured inspiratory and expiratory resistances to breathing through each system at various tidal volumes and total gas flows into the circuit. These values were compared to resistances created by breathing through an appropriately sized endotracheal tube. Although there was lower resistance to ventilation through Jackson-Rees system, both systems had lower resistances for almost all flows tested than breathing through an endotracheal tube alone (p less than 0.05). The paediatric circle absorber system is an efficient apparatus for anaesthetising spontaneously breathing infants.

Entities:  

Mesh:

Year:  1988        PMID: 3349552     DOI: 10.1007/BF03010540

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  7 in total

1.  ACID-BASE BALANCE IN INFANTS DURING HALOTHANE ANESTHESIA WITH THE USE OF AN ADULT CIRCLE-ABSORPTION SYSTEM.

Authors:  T D GRAFF; R S HOLZMAN; D W BENSON
Journal:  Anesth Analg       Date:  1964 Sep-Oct       Impact factor: 5.108

2.  An assessment of the Revell circulator.

Authors:  P J ROFFEY; D G REVELL; L E MORRIS
Journal:  Anesthesiology       Date:  1961 Jul-Aug       Impact factor: 7.892

3.  A circulator to eliminate mechanical dead space in circle absorption systems.

Authors:  D G REVELL
Journal:  Can Anaesth Soc J       Date:  1959-04

Review 4.  AYRE'S T-PIECE: A REVIEW OF ITS MODIFICATIONS.

Authors:  G A HARRISON
Journal:  Br J Anaesth       Date:  1964-02       Impact factor: 9.166

5.  Pediatric circle absorber.

Authors:  E R BLOOMQUIST
Journal:  Anesthesiology       Date:  1957 Sep-Oct       Impact factor: 7.892

6.  Rebreathing in pediatric anesthesia: recommendations and descriptions of improvements in apparatus.

Authors:  J ADRIANI; T GRIGGS
Journal:  Anesthesiology       Date:  1953-07       Impact factor: 7.892

7.  Agents and techniques employed in pediatric anesthesia.

Authors:  C R STEPHEN; H M SLATER
Journal:  Curr Res Anesth Analg       Date:  1950 Sep-Oct
  7 in total
  1 in total

Review 1.  The closed circuit and the low flow systems.

Authors:  S Parthasarathy
Journal:  Indian J Anaesth       Date:  2013-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.