Literature DB >> 33493681

Biomechanical comparison of semirigid junctional fixation techniques to prevent proximal junctional failure after thoracolumbar adult spinal deformity correction.

Remco J P Doodkorte1, Alex K Roth2, Jacobus J Arts2, L M Arno Lataster3, Lodewijk W van Rhijn2, Paul C Willems2.   

Abstract

BACKGROUND CONTEXT: Adult spinal deformity patients treated operatively by long-segment instrumented spinal fusion are prone to develop proximal junctional kyphosis (PJK) and failure (PJF). A gradual transition in range of motion (ROM) at the proximal end of spinal instrumentation may reduce the incidence of PJK and PJF, however, previously evaluated techniques have not directly been compared.
PURPOSE: To determine the biomechanical characteristics of five different posterior spinal instrumentation techniques to achieve semirigid junctional fixation, or "topping-off," between the rigid pedicle screw fixation (PSF) and the proximal uninstrumented spine. STUDY
DESIGN: Biomechanical cadaveric study.
METHODS: Seven fresh-frozen human cadaveric spine segments (T8-L3) were subjected to ex vivo pure moment loading in flexion-extension, lateral bending and axial rotation up to 5 Nm. The native condition, three-level PSF (T11-L2), PSF with supplemental transverse process hooks at T10 (TPH), and two sublaminar taping techniques (knotted and clamped) as one- (T10) or two-level (T9, T10) semirigid junctional fixation techniques were compared. The ROM and neutral zone (NZ) of the segments were normalized to the native condition. The linearity of the transition zones over three or four segments was determined through linear regression analysis.
RESULTS: All techniques achieved a significantly reduced ROM at T10-T11 in flexion-extension and axial rotation relative to the PSF condition. Additionally, both two-level sublaminar taping techniques (CT2, KT2) had a significantly reduced ROM at T9-T10. One-level clamped sublaminar tape (CT1) had a significantly lower ROM and NZ compared with one-level knotted sublaminar tape (KT1) at T10-T11. Linear regression analysis showed the highest linear correlation between ROM and vertebral level for TPH and the lowest linear correlation for CT2.
CONCLUSIONS: All studied semirigid junctional fixation techniques significantly reduced the ROM at the junctional levels and thus provide a more gradual transition than pedicle screws. TPH achieves the most linear transition over three vertebrae, whereas KT2 achieves that over four vertebrae. In contrast, CT2 effectively is a one-level semirigid junctional fixation technique with a shift in the upper rigid fixation level. Clamped sublaminar tape reduces the NZ greatly, whereas knotted sublaminar tape and TPH maintain a more physiologic NZ. Clinical validation is ultimately required to translate the biomechanics of various semirigid junctional fixation techniques into the clinical goal of reducing the incidence of proximal junctional kyphosis and failure. CLINICAL SIGNIFICANCE: The direct biomechanical comparison of multiple instrumentation techniques that aim to reduce the incidence of PJK after thoracolumbar spinal fusion surgery provides a basis upon which clinical studies could be designed. Furthermore, the data provided in this study can be used to further analyze the biomechanical effects of the studied techniques using finite element models to better predict their post-operative effectiveness.
Copyright © 2021 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Adult spinal deformity, Biomechanics, Proximal junctional kyphosis, Proximal junctional failure; Semirigid, Topping-off

Year:  2021        PMID: 33493681     DOI: 10.1016/j.spinee.2021.01.017

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  4 in total

Review 1.  S2 alar-iliac screw versus traditional iliac screw for spinopelvic fixation: a systematic review of comparative biomechanical studies.

Authors:  Takashi Hirase; Caleb Shin; Jeremiah Ling; Brian Phelps; Varan Haghshenas; Comron Saifi; Darrell S Hanson
Journal:  Spine Deform       Date:  2022-06-28

2.  Influence of spinal lordosis correction location on proximal junctional failure: a biomechanical study.

Authors:  Maeva Lopez Poncelas; Luigi La Barbera; Jeremy J Rawlinson; David W Polly; Carl-Eric Aubin
Journal:  Spine Deform       Date:  2022-09-09

3.  Proximal junctional failure after surgical instrumentation in adult spinal deformity: biomechanical assessment of proximal instrumentation stiffness.

Authors:  Maeva Lopez Poncelas; Luigi La Barbera; Jeremy Rawlinson; Dennis Crandall; Carl-Eric Aubin
Journal:  Spine Deform       Date:  2022-09-09

4.  Instrumentation Techniques to Prevent Proximal Junctional Kyphosis and Proximal Junctional Failure in Adult Spinal Deformity Correction: A Systematic Review of Clinical Studies.

Authors:  Timon F G Vercoulen; Remco J P Doodkorte; Alex Roth; Rob de Bie; Paul C Willems
Journal:  Global Spine J       Date:  2021-07-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.