Literature DB >> 33486137

Carboxyl-fentanyl detection using optical fibre grating-based sensors functionalised with molecularly imprinted nanoparticles.

LiangLiang Liu1, Fabiana Grillo2, Francesco Canfarotta3, Michael Whitcombe2, Stephen P Morgan1, Sergey Piletsky2, Ricardo Correia1, ChenYang He1, Andrew Norris4, Serhiy Korposh5.   

Abstract

Butyrylfentanyl is a new designer drug reported with growing use and related deaths. Routine toxicological analyses of this novel synthetic opioid drug have not been established yet. This work reports a fibre optic sensor that measures carboxyl-fentanyl which is the major metabolite of butyrylfentanyl presented in blood, providing a promising tool for detecting butyrylfentanyl intoxication. A long period fibre grating (LPG) sensor array operating at phase-matching condition is deployed in combination with a state-of-the-art molecular imprinting technique. Nano-sized molecularly imprinted polymers (nanoMIPs) are synthesised via a solid-phase approach and coated on the surface of an LPG array. An LPG array consists of two parts: a detection and a reference LPG. The former is functionalised with nanoMIPs prior to the measurements, whilst the latter is used to take into account the temperature response of the detection LPG. The developed sensor exhibits a gradual response over increasing concentrations of carboxyl-fentanyl from 0 to 1000 ng/mL with a minimal detected concentration of 50 ng/mL, that corresponds to a wavelength shift of 1.20 ± 0.2 nm. The Langmuir adsorption isotherm is applied to fit the analytical data which reveal a binding constant of 2.03 μM-1. The developed sensor shows high selectivity in detecting carboxyl-fentanyl among other drugs and potential interferents including morphine, cocaine, glucose and albumin. It shows a certain degree of cross-response to fentanyl which shares the same binding sites as carboxyl-fentanyl and therefore can be potentially used to detect fentanyl.
Copyright © 2021 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fentanyl; Molecular imprinting; Optical fibre long period grating

Mesh:

Substances:

Year:  2021        PMID: 33486137     DOI: 10.1016/j.bios.2021.113002

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  1 in total

1.  Electrochemical sensor for rapid detection of fentanyl using laser-induced porous carbon-electrodes.

Authors:  Rupesh Kumar Mishra; Akshay Krishnakumar; Amin Zareei; Ulisses Heredia-Rivera; Rahim Rahimi
Journal:  Mikrochim Acta       Date:  2022-04-25       Impact factor: 5.833

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.