Literature DB >> 33486065

Stand-alone coracoclavicular suture repair achieves very good results in unstable distal clavicle fractures at a minimum follow-up of 1 year.

Christoph J Laux1, Christina Villefort2, Rany El Nashar2, Jan M Farei-Campagna2, Florian Grubhofer2, Samy Bouaicha2, Christian Gerber2, Dominik C Meyer2, Karl Wieser2.   

Abstract

BACKGROUND: The treatment of unstable (Neer type IIB and V) extra-articular distal clavicle fractures remains challenging, especially when encountering a small lateral fragment which does not allow for sufficient screw purchase. It was the purpose of this study to present the clinical and radiologic outcome of a consecutive series of patients treated by a stand-alone coracoclavicular stabilization using a so-called cow-hitch technique with a suture anchor.
METHODS: Nineteen patients were treated with a specific surgical technique for distal clavicle fractures (11 left, 8 right) with either rupture or bony avulsion of the coracoclavicular ligaments. Fourteen patients were examined in our outpatient clinic for the purpose of this study after a mean follow-up of 5 years (1-12.2 years). The examination included scoring according to Constant Murley score (CMS), the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), the Subjective Shoulder Value (SSV), and follow-up radiographs. Two additional patients were amenable to a telephone interview.
RESULTS: All patients reported very good subjective results, with a mean SSV of 92% and a mean ASES score of 96%. The CMS resulted in average absolute values of 92 points. Fractures consolidated in 95% of cases. One patient developed an asymptomatic pseudarthrosis. The coracoclavicular distance was restored from 21 mm preoperatively to 11 mm at the final follow-up and finally showed an average side-to-side difference of +1.8 mm. Sports activities were fully resumed after an average of 4.7 months.
CONCLUSION: The coracoclavicular stand-alone cow-hitch suture repair for unstable distal clavicle fractures is a minimally invasive fixation technique without prominent hardware that allows for an anatomic reduction and stable fixation with a low complication and high bony union rate. Both radiographic and clinical long-term results are very satisfactory.
Copyright © 2021 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Distal clavicle fracture; coracoclavicular instability; coracoclavicular ligaments; cow-hitch; knot tying technique; suture repair

Year:  2021        PMID: 33486065     DOI: 10.1016/j.jse.2020.11.028

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  2 in total

1.  [Effectiveness analysis of Endobutton plate combined with high-strength suture Nice knot fixation in the treatment of distal clavicle fractures].

Authors:  Jishi Jiang; Yunlei Zhai; Xubing Huang; Wei Jiao; Wei Wang; Biao Guo; Li Li; Xuejun Li; Yu Nie; Haiyang Yu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-02-15

2.  Fixation of distal clavicle fractures with coracoclavicular instability: a comparative biomechanical study in human cadavers.

Authors:  Christoph J Laux; Paul Borbas; Christina Villefort; Simon Hofstede; Lukas Ernstbrunner; Karl Wieser
Journal:  JSES Int       Date:  2021-09-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.