Literature DB >> 33485578

Simple paper-based colorimetric and fluorescent glucose sensor using N-doped carbon dots and metal oxide hybrid structures.

Yen-Linh Thi Ngo1, Phi Luan Nguyen2, Jayasmita Jana1, Won Mook Choi1, Jin Suk Chung1, Seung Hyun Hur3.   

Abstract

A new strategy for the fluorescent and colorimetric sensing of hydrogen peroxide (H2O2) and glucose based on the metal oxide - carbon-dot hybrid structure was investigated. The sensing system is related to the catalytic oxidation reaction of glucose-by-glucose oxidase (GOx) to H2O2. In this study, a metal oxide hybrid with nitrogen-doped carbon dots (MFNCDs) that showed intrinsic peroxidase-like activity was synthesized and used as a catalyst instead of GOx to oxidize 3,3',5,5'-tetramethylbenzidine (TMB) to blue-emitting oxidized TMB (oxTMB) in the presence of hydrogen peroxide (H2O2). The fluorescence of MFNCDs/TMB at 405 nm was quenched in the presence of H2O2 through the inner filter effect (IFE) and electron transfer within MFNCDs, oxTMB, and glucose system. Therefore, the fluorescence and absorbance intensity can be applied to the quantitative determination of the concentration of H2O2 and glucose with a wide linear range. The detection limit for H2O2 and glucose based on the colorimetric method were as low as 84 nM and 0.41 μM, respectively. In contrast, the detection limit for H2O2 and glucose based on the fluorescent method were as low as 97 nM and 0.85 μM, respectively. Furthermore, the colorimetric readout on the paper device based on the changing color of the solution could also be integrated with a smartphone platform to conduct the on-site analysis of glucose without the use of the spectrometer. In addition, this dual sensor can be applied to detect glucose in real serum with highly accurate results, making it a good candidate for biosensor applications.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Carbon dots; Colorimetric; Fluorescence; Mimetic catalyst; Paper-sensor device

Mesh:

Substances:

Year:  2020        PMID: 33485578     DOI: 10.1016/j.aca.2020.11.023

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Mesoporous MnFe2O4 magnetic nanoparticles as a peroxidase mimic for the colorimetric detection of urine glucose.

Authors:  Ke Liu; Jiaxing Su; Jiangong Liang; Yuan Wu
Journal:  RSC Adv       Date:  2021-08-23       Impact factor: 4.036

Review 2.  Potential Development of N-Doped Carbon Dots and Metal-Oxide Carbon Dot Composites for Chemical and Biosensing.

Authors:  Yogita Sahu; Ayesha Hashmi; Rajmani Patel; Ajaya K Singh; Md Abu Bin Hasan Susan; Sónia A C Carabineiro
Journal:  Nanomaterials (Basel)       Date:  2022-09-30       Impact factor: 5.719

Review 3.  Synthesis of Doped/Hybrid Carbon Dots and Their Biomedical Application.

Authors:  Vijay Bhooshan Kumar; Ze'ev Porat; Aharon Gedanken
Journal:  Nanomaterials (Basel)       Date:  2022-03-08       Impact factor: 5.076

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.