Literature DB >> 33480669

Dual-Signaling Electrochemical Ratiometric Method for Competitive Immunoassay of CYFRA21-1 Based on Urchin-like Fe3O4@PDA-Ag and Ni3Si2O5(OH)4-Au Absorbed Methylene Blue Nanotubes.

Liu Qu1, Lei Yang1, Yueyuan Li2, Xiang Ren1, Huan Wang1, Dawei Fan1, Xueying Wang1, Qin Wei1, Huangxian Ju1.   

Abstract

A novel ratiometric electrochemical (EC) sensing platform was established for sensitive immunoassay of target cytokeratin 19 fragment 21-1 (CYFRA21-1) biomarker by combining competitive immunoreaction and multisignal output. This immunosensor utilized Ag nanoparticles (NPs)-functionalized urchin-like Fe3O4@polydopamine (u-Fe3O4@PDA-Ag) as a matrix to immobilize CYFRA21-1 antigens and methylene blue (MB)-absorbed Ni3Si2O5(OH)4-Au nanotubes (NTs) to label the anti-CYFRA21-1 (Ab). During the competitive immunoreaction, square wave voltammetric (SWV) current changes of Ag NPs from u-Fe3O4@PDA-Ag indicator and MB from Ni3Si2O5(OH)4-Au/MB indicator are relevant to the dosage of CYFRA21-1-acquired Ni3Si2O5(OH)4-Au/MB/Ab. More importantly, numerous CYFRA21-1 loaded stably on u-Fe3O4@PDA-Ag exhibited strong competitive capacity toward the target-CYFRA21-1 to combine Ni3Si2O5(OH)4-Au/MB/Ab, causing sensitive changes in the ratio of two measured SWV currents. Prominently, "ΔI = ΔIMB + |ΔIAg NPs|" (ΔIMB and |ΔIAg NPs| represents the change values of the oxidation peak currents of MB and Ag NPs, respectively) could be regarded as significantly amplifying the signal response and ultimately improving the sensitivity of CYFRA21-1 detection, from which we derived a wide dynamic range from 500 fg/mL to 50 ng/mL and a low detection limit of 0.39 pg/mL (S/N = 3). This work may exert a profound impact on monitoring other biomarkers in early diagnosis of diseases.

Entities:  

Keywords:  Ag-functionalized urchin-like Fe3O4@PDA; MB-absorbed Ni3Si2O5(OH)4-Au NTs; competitive immunoreaction; multisignal output; ratiometric

Mesh:

Substances:

Year:  2021        PMID: 33480669     DOI: 10.1021/acsami.0c20049

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  3 in total

1.  An ultrasensitive ratiometric immunosensor based on the ratios of conjugated distyrylbenzene derivative nanosheets with AIECL properties and electrochemical signal for CYFRA21-1 detection.

Authors:  Xiaoyi Lv; Mengmeng Bi; Xiaoyun Xu; Yanping Li; Chao Geng; Bo Cui; Yishan Fang
Journal:  Anal Bioanal Chem       Date:  2021-11-05       Impact factor: 4.142

2.  A sandwich-type electrochemical immunosensor for CYFRA 21-1 based on probe-confined in PtPd/polydopamine/hollow carbon spheres coupled with dendritic Au@Rh nanocrystals.

Authors:  Yi-Ge Feng; Jia-Wen He; Di-Nan Chen; Lu-Yao Jiang; Ai-Jun Wang; Ning Bao; Jiu-Ju Feng
Journal:  Mikrochim Acta       Date:  2022-07-05       Impact factor: 6.408

Review 3.  Electrochemical Signal Substance for Multiplexed Immunosensing Interface Construction: A Mini Review.

Authors:  Jiejie Feng; Changshun Chu; Zhanfang Ma
Journal:  Molecules       Date:  2022-01-02       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.