Literature DB >> 33478630

Incidence, Predictors, and Implications of Permanent Pacemaker Requirement After Transcatheter Aortic Valve Replacement.

Yasser Sammour1, Amar Krishnaswamy2, Arnav Kumar3, Rishi Puri2, Khaldoun G Tarakji2, Najdat Bazarbashi4, Serge Harb2, Brian Griffin2, Lars Svensson2, Oussama Wazni2, Samir R Kapadia5.   

Abstract

Transcatheter aortic valve replacement (TAVR) is a safe and feasible alternative to surgery in patients with symptomatic severe aortic stenosis regardless of the surgical risk. Conduction abnormalities requiring permanent pacemaker (PPM) implantation remain a common finding after TAVR due to the close proximity of the atrioventricular conduction system to the aortic root. High-grade atrioventricular block and new onset left bundle branch block (LBBB) are the most commonly reported conduction abnormalities after TAVR. The overall rate of PPM implantation after TAVR varies and is related to pre-procedural and intraprocedural factors. The available literature regarding the impact of conduction abnormalities and PPM requirement on morbidity and mortality is still conflicting. Pre-procedural conduction abnormalities such as right bundle branch block and LBBB have been linked with increased PPM implantation and mortality after TAVR. When screening patients for TAVR, heart teams should be aware of various anatomical and pathophysiological conditions that make patients more susceptible to increased risk of conduction abnormalities and PPM requirement after the procedure. This is particularly important as TAVR has been recently approved for patients with low surgical risk. The purpose of this review is to discuss the incidence, predictors, impact, and management of the various conduction abnormalities requiring PPM implantation in patients undergoing TAVR.
Copyright © 2021 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  PPM; TAVR; conduction disturbances; state-of-the-art

Mesh:

Year:  2021        PMID: 33478630     DOI: 10.1016/j.jcin.2020.09.063

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  11 in total

1.  Sex Differences in the Impact of Aortic Valve Calcium Score on Mortality After Transcatheter Aortic Valve Replacement.

Authors:  Parth P Patel; Abdallah El Sabbagh; Patrick W Johnson; Rayan Suliman; Najiyah Salwa; Andrea Carolina Morales-Lara; Peter Pollak; Mohamad Yamani; Pragnesh Parikh; Sushilkumar K Sonavane; Carolyn Landolfo; Mohamad Adnan Alkhouli; Mackram F Eleid; Mayra Guerrero; F David Fortuin; John Sweeney; Peter A Noseworthy; Rickey E Carter; Demilade Adedinsewo
Journal:  Circ Cardiovasc Imaging       Date:  2022-08-03       Impact factor: 8.589

2.  10-Year Impact of Transcatheter Aortic Valve Replacement Leaflet Design (Intra- Versus Supra-Annular) in Mortality and Hemodynamic Performance.

Authors:  Andrea Scotti; Luca Nai Fovino; Augustin Coisne; Tommaso Fabris; Francesco Cardaioli; Mauro Massussi; Giulio Rodinò; Alberto Barolo; Mauro Boiago; Saverio Continisio; Carolina Montonati; Tommaso Sciarretta; Vittorio Zuccarelli; Valentina Bernardini; Giulia Masiero; Massimo Napodano; Chiara Fraccaro; Alfredo Marchese; Giovanni Esposito; Juan F Granada; Azeem Latib; Sabino Iliceto; Giuseppe Tarantini
Journal:  Front Cardiovasc Med       Date:  2022-06-08

3.  Evaluation of the 2021 European Society of Cardiology guidelines in pre-existing right bundle branch block patients undergoing transcatheter aortic valve implantation with a balloon-expandable valve.

Authors:  Toshiaki Isogai; Iryna Dykun; Ankit Agrawal; Shashank Shekhar; Khaldoun G Tarakji; Oussama M Wazni; Ankur Kalra; Amar Krishnaswamy; Grant W Reed; Samir R Kapadia; Rishi Puri
Journal:  Eur Heart J Open       Date:  2022-03-11

4.  Mid- to Long-Term Clinical and Echocardiographic Effects of Post-procedural Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Authors:  Shun Xu; Enrui Zhang; Zhiyong Qian; Jinyu Sun; Fengwei Zou; Yao Wang; Xiaofeng Hou; Jiangang Zou
Journal:  Front Cardiovasc Med       Date:  2022-06-28

5.  Pooled-Analysis of Association of Sievers Bicuspid Aortic Valve Morphology With New Permanent Pacemaker and Conduction Abnormalities After Transcatheter Aortic Valve Replacement.

Authors:  Jiajun Zhang; Xiaoxing Li; Feng Xu; Yuguo Chen; Chuanbao Li
Journal:  Front Cardiovasc Med       Date:  2022-05-26

6.  Commentary: Is the need for permanent pacemaker after aortic valve replacement such a big deal?

Authors:  Sarah Yousef; Danny Chu
Journal:  JTCVS Tech       Date:  2021-10-26

7.  Propensity-matched comparison of balloon-expandable and self-expanding valves for transcatheter aortic valve replacement in a Chinese population.

Authors:  Wen-Bin Ou-Yang; Wei Wang; Jie Dong; Yong-Quan Xie; Jun-Yi Wan; Zi-Qi Yue; Shou-Zheng Wang; Hong Meng; Xu Wang; Dong-Hui Xu; Feng-Wen Zhang; Jing Dong; Xiang-Bin Pan; Ge-Jun Zhang
Journal:  Ann Transl Med       Date:  2022-01

8.  Preprocedural and procedural variables that predict new-onset conduction disturbances after transcatheter aortic valve replacement.

Authors:  Wongsaput Boonyakiatwattana; Adisak Maneesai; Vithaya Chaithiraphan; Decho Jakrapanichakul; Pranya Sakiyalak; Narathip Chunhamaneewat; Worawong Slisatkorn; Chunhakasem Chotinaiwattarakul; Rungtiwa Pongakasira; Nattawut Wongpraparut
Journal:  BMC Cardiovasc Disord       Date:  2022-03-31       Impact factor: 2.298

Review 9.  Application of cardiovascular 3-dimensional printing in Transcatheter aortic valve replacement.

Authors:  Yanyan Ma; Yu Mao; Guangyu Zhu; Jian Yang
Journal:  Cell Regen       Date:  2022-09-19

10.  Transcatheter Aortic Valve Replacement with the Self-Expandable Core Valve Evolut Prosthesis Using the Cusp-Overlap vs. Tricusp-View.

Authors:  Philipp Maximilian Doldi; Lukas Stolz; Felix Escher; Julius Steffen; Jonas Gmeiner; Daniel Roden; Marie Linnemann; Kornelia Löw; Simon Deseive; Thomas J Stocker; Martin Orban; Hans Theiss; Konstantinos Rizas; Adrian Curta; Sebastian Sadoni; Joscha Buech; Dominik Joskowiak; Sven Peterss; Christian Hagl; Steffen Massberg; Jörg Hausleiter; Daniel Braun
Journal:  J Clin Med       Date:  2022-03-12       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.