Kawaljit Kaur1, Winny Chelangat1,2, Sergey I Druzhinin1, Nancy Wangechi Karuri3, Mareike Müller1, Holger Schönherr1. 1. Physical Chemistry I & Research Center of Micro and Nanochemistry and Engineering (Cμ), Department of Chemistry and Biology, University of Siegen, Adolf-Reichwein-Straße 2, 57076 Siegen, Germany. 2. Mechatronics Engineering Department, Dedan Kimathi University of Technology, Nyeri-Mweiga Road, Nyeri 10143, Kenya. 3. Chemical Engineering Department, Dedan Kimathi University of Technology, Nyeri-Mweiga Road, Nyeri 10143, Kenya.
Abstract
There is a growing demand for rapid and sensitive detection approaches for pathogenic bacteria that can be applied by non-specialists in non-laboratory field settings. Here, the detection of the typical E. coli enzyme β-glucuronidase using a chitosan-based sensing hydrogel-coated paper sensor and the detailed analysis of the reaction kinetics, as detected by a smartphone camera, is reported. The chromogenic reporter unit affords an intense blue color in a two-step reaction, which was analyzed using a modified Michaelis-Menten approach. This generalizable approach can be used to determine the limit of detection and comprises an invaluable tool to characterize the performance of lab-in-a-phone type approaches. For the particular system analyzed, the ratio of reaction rate and equilibrium constants of the enzyme-substrate complex are 0.3 and 0.9 pM-1h-1 for β-glucuronidase in phosphate buffered saline and lysogeny broth, respectively. The minimal degree of substrate conversion for detection of the indigo pigment formed during the reaction is 0.15, while the minimal time required for detection in this particular system is ~2 h at an enzyme concentration of 100 nM. Therefore, this approach is applicable for quantitative lab-in-a-phone based point of care detection systems that are based on enzymatic substrate conversion via bacterial enzymes.
There is a growing demand for rapid and sensitive detection approaches for pathogenic bacteria that can be applied by non-specialists in non-laboratory field settings. Here, the detection of the typical E. coli enzyme β-glucuronidase using a pan class="Chemical">chitosan-based sensing hydrogel-coated paper sensor and the detailed analysis of the reaction kinetics, as detected by a smartphone camera, is reported. The chromogenic reporter unit affords an intense blue color in a two-step reaction, which was analyzed using a modified Michaelis-Menten approach. This generalizable approach can be used to determine the limit of detection and comprises an invaluable tool to characterize the performance of lab-in-a-phone type approaches. For the particular system analyzed, the ratio of reaction rate and equilibrium constants of the enzyme-substrate complex are 0.3 and 0.9 pM-1h-1 for β-glucuronidase in phosphate buffered saline and lysogeny broth, respectively. The minimal degree of substrate conversion for detection of the indigo pigment formed during the reaction is 0.15, while the minimal time required for detection in this particular system is ~2 h at an enzyme concentration of 100 nM. Therefore, this approach is applicable for quantitative lab-in-a-phone based point of care detection systems that are based on enzymatic substrate conversion via bacterial enzymes.
Authors: Joel Songok; Mikko Tuominen; Hannu Teisala; Janne Haapanen; Jyrki Mäkelä; Jurkka Kuusipalo; Martti Toivakka Journal: ACS Appl Mater Interfaces Date: 2014-11-04 Impact factor: 9.229
Authors: Katherine E Boehle; Jake Gilliand; Christopher R Wheeldon; Amethyst Holder; Jaclyn A Adkins; Brian J Geiss; Elizabeth P Ryan; Charles S Henry Journal: Angew Chem Int Ed Engl Date: 2017-05-05 Impact factor: 15.336
Authors: Jaclyn A Adkins; Katherine Boehle; Colin Friend; Briana Chamberlain; Bledar Bisha; Charles S Henry Journal: Anal Chem Date: 2017-03-07 Impact factor: 6.986