Enhancement of Gingival Tissue Adherence of Zirconia Implant Posts: In Vitro Study.

Alexandra Zühlke1, Michael Gasik1, Khalil Shahramian2,3, Timo Närhi2,3,4, Yevgen Bilotsky5, Ilkka Kangasniemi6.   

Abstract

Prevention of bacterial inflammation around dental implants (peri-implantitis) is one of the keys to success of the implantation and can be achieved by securing the gingival tissue-abutment interface preventing penetration of bacteria. Modern dental practice has adopted zirconia abutments in place of titanium, but the adhesion of gingival tissue to zirconia is inferior to titanium. The aim of this study was to assess and improve the adhesion of mucosal tissues to zirconia posts using sol-gel derived TiO2 coating following dynamic mechanical testing. The posts were cultivated with porcine bone-gingival tissue specimens in vitro for 7 and 14 days and then subjected to dynamic mechanical analysis simulating physiological loading at 1 Hz up to 50 μm amplitude. In parallel in silico analysis of stresses and strains have been made simulating "the worst case" when the fixture fails in osseointegration while the abutment still holds. Results show treatment of zirconia can lead to double interface stiffness (static shear stiffness values from 5-10 to 17-23 kPa and dynamic from 20-50 to 60-125 kPa), invariant viscostiffness (from 5-35 to 45-90 kPa·sα) and material memory values (increased from 0.06-0.10 to 0.17-0.25), which is beneficial in preventing bacterial contamination in dental implants. This suggests TiO2-coated zirconia abutments may have a significant clinical benefit for prevention of the bacterial contamination.

Entities:  

Keywords:  abutment; dental; dynamic mechanical analysis; gingiva; in silico; in vitro; modeling; zirconia

Year:  2021        PMID: 33477782      PMCID: PMC7832313          DOI: 10.3390/ma14020455

Source DB:  PubMed          Journal:  Materials (Basel)        ISSN: 1996-1944            Impact factor:   3.623


  27 in total

1.  Subcutaneous microfabricated surfaces inhibit epithelial recession and promote long-term survival of percutaneous implants.

Authors:  Babak Chehroudi; Donald Maxwell Brunette
Journal:  Biomaterials       Date:  2002-01       Impact factor: 12.479

2.  In vitro time-dependent response of periodontal ligament to mechanical loading.

Authors:  Colin S Sanctuary; H W Anselm Wiskott; Jörn Justiz; John Botsis; Urs C Belser
Journal:  J Appl Physiol (1985)       Date:  2005-08-18

Review 3.  The effect of material characteristics, of surface topography and of implant components and connections on soft tissue integration: a literature review.

Authors:  Eric Rompen; Olivier Domken; Marco Degidi; Ana Emilia Farias Pontes; Adriano Piattelli
Journal:  Clin Oral Implants Res       Date:  2006-10       Impact factor: 5.977

Review 4.  State of the art of zirconia for dental applications.

Authors:  Isabelle Denry; J Robert Kelly
Journal:  Dent Mater       Date:  2007-07-19       Impact factor: 5.304

5.  Effects of different torque levels on the implant-abutment interface in a conical internal connection.

Authors:  Sergio Alexandre Gehrke; Jamil Awad Shibli; Jaime Sardá Aramburú Junior; José Eduardo Maté Sánchez de Val; José Luis Calvo-Girardo; Berenice Anina Dedavid
Journal:  Braz Oral Res       Date:  2016-03-15

6.  The pressures exerted on the trachea by endotracheal inflatable cuffs.

Authors:  G T Knowlson; H F Bassett
Journal:  Br J Anaesth       Date:  1970-10       Impact factor: 9.166

7.  Effect of different abutment materials (zirconia or titanium) on the crestal bone height in 1 year.

Authors:  Vinayak Bharate; Yogesh Kumar; Dheeraj Koli; Gunjan Pruthi; Veena Jain
Journal:  J Oral Biol Craniofac Res       Date:  2019-10-24

8.  Zirconia implants with improved attachment to the gingival tissue.

Authors:  Khalil Shahramian; Michael Gasik; Ilkka Kangasniemi; X Frank Walboomers; Jaana Willberg; Aous Abdulmajeed; Timo Närhi
Journal:  J Periodontol       Date:  2020-03-12       Impact factor: 6.993

Review 9.  Clinical trials in zirconia: a systematic review.

Authors:  B Al-Amleh; K Lyons; M Swain
Journal:  J Oral Rehabil       Date:  2010-04-09       Impact factor: 3.837

Review 10.  Understanding biomaterial-tissue interface quality: combined in vitro evaluation.

Authors:  Michael Gasik
Journal:  Sci Technol Adv Mater       Date:  2017-07-31       Impact factor: 8.090

View more
  3 in total

Review 1.  Customized Root-Analogue Implants: A Review on Outcomes from Clinical Trials and Case Reports.

Authors:  Telma Dantas; Sara Madeira; Michael Gasik; Paula Vaz; Filipe Silva
Journal:  Materials (Basel)       Date:  2021-04-29       Impact factor: 3.623

Review 2.  Junctional epithelium and hemidesmosomes: Tape and rivets for solving the "percutaneous device dilemma" in dental and other permanent implants.

Authors:  Nicholas G Fischer; Conrado Aparicio
Journal:  Bioact Mater       Date:  2022-03-19

3.  Biomechanical Properties of Bone and Mucosa for Design and Application of Dental Implants.

Authors:  Michael Gasik; France Lambert; Miljana Bacevic
Journal:  Materials (Basel)       Date:  2021-05-26       Impact factor: 3.623